Fiber-Optic Sensor Based on Core-Offset Fused Unequal-Length Fiber Segments to Improve Ultrasound Detection Sensitivity

被引:8
作者
Fan, Huibo [1 ,2 ]
Chen, Liang [1 ]
Bao, Xiaoyi [1 ]
机构
[1] Univ Ottawa, Dept Phys, Ottawa, ON 61N KN5, Canada
[2] Yangzhou Univ, Coll Phys Sci & Technol, Yangzhou 225002, Jiangsu, Peoples R China
基金
加拿大自然科学与工程研究理事会;
关键词
Fabry-Perot interferometer; ultrasound; core-offset splicing; REFRACTIVE-INDEX; STRAIN; TEMPERATURE;
D O I
10.1109/JSEN.2020.2986405
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fiber-optic sensors fabricated by core-offset splicing method with 2 to 12 unequal-length single-mode fiber (Corning SMF-28) segments are demonstrated for the ultrasound detection. High-order modes are created in the air and silica cladding to enhance multi-mode interference, leading to large spectrum range comparing to that case with the same number of equal fiber segments. This leads to larger wavelength tuning range which overcomes the free-spectrum-range limitation in Fabry-Perot interferometer with multiple equal fiber segments. Furthermore, wavelength shift associated with power change, and characterized as high spectrum slope defined as 1st derivative of the reflection spectrum, is realized based on these unequal-length and asymmetric waveguides, which enhances the sensitivity of ultrasound detection. Using piezoelectric transducer as ultrasound generator at 260 kHz with 10 V peak-to-peak driving voltage, we detect ultrasound response based on the fiber devices with 2 to 12 segments as sensing unit or as feedback/sensor in a fiber laser. In the former sensor case, the ultrasound response via photo-detector could be increased from 15.5 mV for the core-offset fiber with 2 unequal-length segments to 115.3 mV for that with 12 segments, corresponding to a factor of 7.4 times improvement due to narrow linewidth of reflection spectrum in the fiber-optic sensor with more unequal-length fiber segments. The fiber laser sensor for the ultrasound detection brings improvement from 31.6 mV to 207.1 mV with the enhancement of 6.6 times, thanks to higher quality factor (Q) due to the optical filter formed by unequal-length core-offset fiber.
引用
收藏
页码:9148 / 9154
页数:7
相关论文
共 21 条
[11]  
Li Z., 2018, P SOC PHOTO-OPT INS
[12]   Strain-based tunable optical microresonator with an in-fiber rectangular air bubble [J].
Liu, Shen ;
Sun, Zhongyuan ;
Zhang, Lin ;
Fu, Cailing ;
Liu, Yu ;
Liao, Changrui ;
He, Jun ;
Bai, Zhiyong ;
Wang, Ying ;
Wang, Yiping .
OPTICS LETTERS, 2018, 43 (17) :4077-4080
[13]   Fiber optic-based laser interferometry array for three-dimensional ultrasound sensing [J].
Ma, Xiangdong ;
Cai, Yiqi ;
Fu, Bo ;
Xu, Lijun ;
Ma, Jianguo .
OPTICS LETTERS, 2019, 44 (23) :5852-5855
[14]   Ultrasensitive strain sensor based on Vernier-effect improved parallel structured fiber-optic Fabry-Perot interferometer [J].
Nan, Tong ;
Liu, Bo ;
Wu, Yongfeng ;
Wang, Junfeng ;
Mao, Yaya ;
Zhao, Lilong ;
Sun, Tingting ;
Wang, Jin .
OPTICS EXPRESS, 2019, 27 (12) :17239-17250
[15]   Hybrid Fiber Fabry-Perot Interferometer With Improved Refractometric Response [J].
Rodriguez-Quiroz, Osvaldo ;
Dominguez-Flores, Carmen E. ;
Monzon-Hernandez, David ;
Moreno-Hernandez, Carlos .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2019, 37 (17) :4268-4274
[16]   Strain sensor based on gourd-shaped single-mode-multimode-single-mode hybrid optical fibre structure [J].
Tian, Ke ;
Farrell, Gerald ;
Wang, Xianfan ;
Yang, Wenlei ;
Xin, Yifan ;
Liang, Haidong ;
Lewis, Elfed ;
Wang, Pengfei .
OPTICS EXPRESS, 2017, 25 (16) :18885-18896
[17]   Strain and Temperature Sensing Characteristics of Single-Mode-Multimode-Single-Mode Structures [J].
Tripathi, Saurabh Mani ;
Kumar, Arun ;
Varshney, Ravi K. ;
Kumar, Y. Bala Pavan ;
Marin, Emmanuel ;
Meunier, Jean-Pierre .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2009, 27 (13) :2348-2356
[18]   A Review of Multimode Interference in Tapered Optical Fibers and Related Applications [J].
Wang, Pengfei ;
Zhao, Haiyan ;
Wang, Xianfan ;
Farrell, Gerald ;
Brambilla, Gilberto .
SENSORS, 2018, 18 (03)
[19]   Simultaneous measurement of refractive index and temperature based on asymmetrical Fabry-Perot interferometer [J].
Wu, Yue ;
Li, Hong ;
Yan, Guang ;
Meng, Fanyong ;
Zhu, Lianqing .
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2019, 61 (09) :2190-2195
[20]   Ultrasensitive refractive index sensor based on parallel-connected dual Fabry-Perot interferometers with Vernier effect [J].
Yao, Tianjun ;
Pu, Shengli ;
Zhao, Yongliang ;
Li, Yuqi .
SENSORS AND ACTUATORS A-PHYSICAL, 2019, 290 (14-19) :14-19