Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System

被引:45
|
作者
Cesareo, Ambra [1 ]
Previtali, Ylenia [1 ]
Biffi, Emilia [2 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] IRCCS E Medea, Bioengn Lab, Inst Sci, I-23842 Bosisio Parini, Lecco, Italy
关键词
principal component analysis; biomedical signal processing; wearable biomedical sensors; wireless sensor network; respiratory monitoring; optoelectronic plethysmography; FALSE DISCOVERY RATE; OPTOELECTRONIC PLETHYSMOGRAPHY; RESPIRATORY RATE; CHEST-WALL; RIB CAGE; ACCELEROMETER; VOLUME; VARIABLES;
D O I
10.3390/s19010088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Breathing frequency (f(B)) is an important vital sign that-if appropriately monitored-may help to predict clinical adverse events. Inertial sensors open the door to the development of low-cost, wearable, and easy-to-use breathing-monitoring systems. The present paper proposes a new posture-independent processing algorithm for breath-by-breath extraction of breathing temporal parameters from chest-wall inclination change signals measured using inertial measurement units. An important step of the processing algorithm is dimension reduction (DR) that allows the extraction of a single respiratory signal starting from 4-component quaternion data. Three different DR methods are proposed and compared in terms of accuracy of breathing temporal parameter estimation, in a group of healthy subjects, considering different breathing patterns and different postures; optoelectronic plethysmography was used as reference system. In this study, we found that the method based on PCA-fusion of the four quaternion components provided the best f(B) estimation performance in terms of mean absolute errors (<2 breaths/min), correlation (r > 0.963) and Bland-Altman Analysis, outperforming the other two methods, based on the selection of a single quaternion component, identified on the basis of spectral analysis; particularly, in supine position, results provided by PCA-based method were even better than those obtained with the ideal quaternion component, determined a posteriori as the one providing the minimum estimation error. The proposed algorithm and system were able to successfully reconstruct the respiration-induced movement, and to accurately determine the respiratory rate in an automatic, position-independent manner.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] A New Approach to Analyzing Cycling Stability Using an Inertial Measurement Unit Sensor
    Joo, Shinhye
    Lee, Gunwoo
    Oh, Cheol
    Choi, Keechoo
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (12) : 5195 - 5202
  • [32] Bilateral step length estimation using a single inertial measurement unit attached to the pelvis
    Koese, Alper
    Cereatti, Andrea
    Della Croce, Ugo
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2012, 9
  • [33] Front-Crawl Instantaneous Velocity Estimation Using a Wearable Inertial Measurement Unit
    Dadashi, Farzin
    Crettenand, Florent
    Millet, Gregoire P.
    Aminian, Kamiar
    SENSORS, 2012, 12 (10): : 12927 - 12939
  • [34] A MICROMACHINED FLUIDIC REDUCED INERTIAL MEASUREMENT UNIT USING THERMAL EXPANSION FLOW PRINCIPLE
    Wang, S. S.
    Gong, X. H.
    Nie, B.
    Yuan, W. Z.
    Chang, H. L.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 1223 - 1226
  • [35] Bilateral step length estimation using a single inertial measurement unit attached to the pelvis
    Alper Köse
    Andrea Cereatti
    Ugo Della Croce
    Journal of NeuroEngineering and Rehabilitation, 9
  • [36] Design of Micro Inertial Measurement Unit Based on Micromachined Thermal Expansion Gas Gyroscope
    Wei Jing
    Zhu Xinhua
    Su Yan
    2013 THIRD INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2013, : 14 - 18
  • [37] A Human-Computer Interaction System Utilizing Inertial Measurement Unit and Convolutional Neural Network
    Fahim, Shahriar Rahman
    Sarker, Yeahia
    Rashiduzzaman, Md
    Islam, Omar Kamrul
    Sarker, Subrato K.
    Das, Sajal K.
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL ENGINEERING (ICAEE), 2019, : 880 - 885
  • [38] Behavior modeling in industrial assembly lines using a wrist-worn inertial measurement unit
    Koskimaki, Heli
    Huikari, Ville
    Siirtola, Pekka
    Roning, Juha
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2013, 4 (02) : 187 - 194
  • [39] Estimating effective contact and flight times using a sacral-mounted inertial measurement unit
    Patoz, Aurelien
    Lussiana, Thibault
    Breine, Bastiaan
    Gindre, Cyrille
    Malatesta, Davide
    JOURNAL OF BIOMECHANICS, 2021, 127
  • [40] Behavior modeling in industrial assembly lines using a wrist-worn inertial measurement unit
    Heli Koskimäki
    Ville Huikari
    Pekka Siirtola
    Juha Röning
    Journal of Ambient Intelligence and Humanized Computing, 2013, 4 : 187 - 194