Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System

被引:45
|
作者
Cesareo, Ambra [1 ]
Previtali, Ylenia [1 ]
Biffi, Emilia [2 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] IRCCS E Medea, Bioengn Lab, Inst Sci, I-23842 Bosisio Parini, Lecco, Italy
关键词
principal component analysis; biomedical signal processing; wearable biomedical sensors; wireless sensor network; respiratory monitoring; optoelectronic plethysmography; FALSE DISCOVERY RATE; OPTOELECTRONIC PLETHYSMOGRAPHY; RESPIRATORY RATE; CHEST-WALL; RIB CAGE; ACCELEROMETER; VOLUME; VARIABLES;
D O I
10.3390/s19010088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Breathing frequency (f(B)) is an important vital sign that-if appropriately monitored-may help to predict clinical adverse events. Inertial sensors open the door to the development of low-cost, wearable, and easy-to-use breathing-monitoring systems. The present paper proposes a new posture-independent processing algorithm for breath-by-breath extraction of breathing temporal parameters from chest-wall inclination change signals measured using inertial measurement units. An important step of the processing algorithm is dimension reduction (DR) that allows the extraction of a single respiratory signal starting from 4-component quaternion data. Three different DR methods are proposed and compared in terms of accuracy of breathing temporal parameter estimation, in a group of healthy subjects, considering different breathing patterns and different postures; optoelectronic plethysmography was used as reference system. In this study, we found that the method based on PCA-fusion of the four quaternion components provided the best f(B) estimation performance in terms of mean absolute errors (<2 breaths/min), correlation (r > 0.963) and Bland-Altman Analysis, outperforming the other two methods, based on the selection of a single quaternion component, identified on the basis of spectral analysis; particularly, in supine position, results provided by PCA-based method were even better than those obtained with the ideal quaternion component, determined a posteriori as the one providing the minimum estimation error. The proposed algorithm and system were able to successfully reconstruct the respiration-induced movement, and to accurately determine the respiratory rate in an automatic, position-independent manner.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units
    Ambra Cesareo
    Emilia Biffi
    David Cuesta-Frau
    Maria G. D’Angelo
    Andrea Aliverti
    Medical & Biological Engineering & Computing, 2020, 58 : 785 - 804
  • [22] Inertial measurement unit-based hip flexion test as an indicator of sprint performance
    Nagahara, Ryu
    Kameda, Mai
    Neville, Jonathon
    Morin, Jean-Benoit
    JOURNAL OF SPORTS SCIENCES, 2020, 38 (01) : 53 - 61
  • [23] Electronically Enhanced Pen Using Inertial Measurement Unit for Handwriting Recognition
    Garud, Hrishikesh
    Kulkarni, Mandar
    2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 1333 - 1338
  • [24] A Kalman/Particle Filter-Based Position and Orientation Estimation Method Using a Position Sensor/Inertial Measurement Unit Hybrid System
    Won, Seong-hoon Peter
    Melek, Wael William
    Golnaraghi, Farid
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (05) : 1787 - 1798
  • [25] Wood Inertial Measurement Unit Based on Laser-induced Graphene
    Li Chen
    Li Hao
    Yang Yanwei
    ACTA PHOTONICA SINICA, 2024, 53 (02)
  • [26] Gait Analysis Based on an Inertial Measurement Unit Sensor: Validation of Spatiotemporal Parameters Calculation in Healthy Young and Older Adults
    Sugiarto, Tommy
    Lin, Yi-Jia
    Chang, Chao-Chin
    Hsu, Wei-Chun
    2017 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2017, : 517 - 522
  • [27] A PC-Based Orientation Sensing using 9-DOF Strapdown Inertial Measurement Unit
    Hun, Lim Chot
    Sze, Lim Tien
    Chet, Koo Voon
    2012 12TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS & VISION (ICARCV), 2012, : 229 - 234
  • [28] The Design of Wearable Wireless Inertial Measurement Unit for Body Motion Capture System
    Liu, Rongkai
    Peng, Liang
    Tong, Lina
    Yang, Kaizhi
    Liu, Bingyang
    2018 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENCE AND SAFETY FOR ROBOTICS (ISR), 2018, : 557 - 562
  • [29] A Fastened Bolt Tracking System for a Hand-held Tool Using an Inertial Measurement Unit and a Triaxial Magnetometer
    Won, Seong-hoon Peter
    Melek, William
    Golnaraghi, Farid
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 2555 - +
  • [30] A New Approach to Analyzing Cycling Stability Using an Inertial Measurement Unit Sensor
    Shinhye Joo
    Gunwoo Lee
    Cheol Oh
    Keechoo Choi
    KSCE Journal of Civil Engineering, 2018, 22 : 5195 - 5202