Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System

被引:45
|
作者
Cesareo, Ambra [1 ]
Previtali, Ylenia [1 ]
Biffi, Emilia [2 ]
Aliverti, Andrea [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] IRCCS E Medea, Bioengn Lab, Inst Sci, I-23842 Bosisio Parini, Lecco, Italy
关键词
principal component analysis; biomedical signal processing; wearable biomedical sensors; wireless sensor network; respiratory monitoring; optoelectronic plethysmography; FALSE DISCOVERY RATE; OPTOELECTRONIC PLETHYSMOGRAPHY; RESPIRATORY RATE; CHEST-WALL; RIB CAGE; ACCELEROMETER; VOLUME; VARIABLES;
D O I
10.3390/s19010088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Breathing frequency (f(B)) is an important vital sign that-if appropriately monitored-may help to predict clinical adverse events. Inertial sensors open the door to the development of low-cost, wearable, and easy-to-use breathing-monitoring systems. The present paper proposes a new posture-independent processing algorithm for breath-by-breath extraction of breathing temporal parameters from chest-wall inclination change signals measured using inertial measurement units. An important step of the processing algorithm is dimension reduction (DR) that allows the extraction of a single respiratory signal starting from 4-component quaternion data. Three different DR methods are proposed and compared in terms of accuracy of breathing temporal parameter estimation, in a group of healthy subjects, considering different breathing patterns and different postures; optoelectronic plethysmography was used as reference system. In this study, we found that the method based on PCA-fusion of the four quaternion components provided the best f(B) estimation performance in terms of mean absolute errors (<2 breaths/min), correlation (r > 0.963) and Bland-Altman Analysis, outperforming the other two methods, based on the selection of a single quaternion component, identified on the basis of spectral analysis; particularly, in supine position, results provided by PCA-based method were even better than those obtained with the ideal quaternion component, determined a posteriori as the one providing the minimum estimation error. The proposed algorithm and system were able to successfully reconstruct the respiration-induced movement, and to accurately determine the respiratory rate in an automatic, position-independent manner.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Wireless inertial measurement unit (IMU)-based posturography
    Valldeperes, Ariadna
    Altuna, Xabier
    Martinez-Basterra, Zurine
    Rossi-Izquierdo, Marcos
    Benitez-Rosario, Jesus
    Perez-Fernandez, Nicolas
    Rey-Martinez, Jorge
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (11) : 3057 - 3065
  • [2] Wireless inertial measurement unit (IMU)-based posturography
    Ariadna Valldeperes
    Xabier Altuna
    Zuriñe Martinez-Basterra
    Marcos Rossi-Izquierdo
    Jesus Benitez-Rosario
    Nicolas Perez-Fernandez
    Jorge Rey-Martinez
    European Archives of Oto-Rhino-Laryngology, 2019, 276 : 3057 - 3065
  • [3] A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units
    Cesareo, Ambra
    Biffi, Emilia
    Cuesta-Frau, David
    D'Angelo, Maria G.
    Aliverti, Andrea
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2020, 58 (04) : 785 - 804
  • [4] MEASURING INTENTION TREMOR IN MULTIPLE SCLEROSIS USING INERTIAL MEASUREMENT UNIT (IMU) DEVICES
    Ketteringham, Laurence P.
    Neild, Simon A.
    Hyde, Richard A.
    Jones, Rosemary J. S.
    Smith, Angela M. Davies
    BIODEVICES 2011, 2011, : 204 - +
  • [5] Consistency of sex-based differences between treadmill and overground running using an inertial measurement unit (IMU)
    Miqueleiz, Unai
    Aguado-Jimenez, Roberto
    Lecumberri, Pablo
    Gorostiaga, Esteban M.
    JOURNAL OF BIOMECHANICS, 2024, 172
  • [6] Fabricated Components Hoisting Activity Recognition and Collision Analysis Based on Inertial Measurement Unit IMU
    Wang, Chen
    Yu, Liangcheng
    Kassem, Mukhtar A.
    Yap, Jeffrey Boon Hui
    Wang, Mengyi
    Ali, Kherun Nita
    BUILDINGS, 2022, 12 (07)
  • [7] Assessment of walking, running, and jumping movement features by using the inertial measurement unit
    Lee, Yin-Shin
    Ho, Chin-Shan
    Shih, Yo
    Chang, Su-Yu
    Robert, Fuele Janos
    Shiang, Tzyy-Yuang
    GAIT & POSTURE, 2015, 41 (04) : 877 - 881
  • [8] Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application
    Aqueveque, Pablo
    Gomez, Britam
    Saavedra, Francisco
    Canales, Cristian
    Contreras, Simon
    Ortega-Bastidas, Paulina
    Cano-de-la-Cuerda, Roberto
    EUROPEAN JOURNAL OF TRANSLATIONAL MYOLOGY, 2020, 30 (02) : 268 - U136
  • [9] Embedded Sensor Fusion and Moving-average Filter for Inertial Measurement Unit (IMU) on the Microcontroller-based Stabilized Platform
    Redhyka, Grace Gita
    Setiawan, Dika
    Soetraprawata, Demi
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON AUTOMATION, COGNITIVE SCIENCE, OPTICS, MICRO ELECTRO-MECHANICAL SYSTEM, AND INFORMATION TECHNOLOGY (ICACOMIT), 2015, : 72 - 77
  • [10] Inter-unit reliability of IMU Step metrics using IMeasureU Blue Trident inertial measurement units for running-based team sport tasks
    Armitage, Mark
    Beato, Marco
    McErlain-Naylor, Stuart A.