PRACTICAL DESIGN OF A HIGH FREQUENCY PHASED-ARRAY ACOUSTIC MICROSCOPE PROBE A PRELIMINARY STUDY

被引:0
作者
Kim, Jeong Nyeon [1 ]
Tutwiler, Richard L. [2 ]
Todd, Judith A. [1 ]
机构
[1] Penn State Univ, Dept Engn Sci & Mech, 227 Hammond Bldg, University Pk, PA 16802 USA
[2] Penn State Univ, Appl Res Lab, University Pk, PA 16802 USA
来源
PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2017, VOL 5 | 2017年
关键词
MATERIAL SIGNATURE; TRANSDUCERS; INVERSION; BONE; LENS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Scanning acoustic microscopy (SAM) has been a well recognized tool for both visualization and quantitative evaluation of materials at the microscale since its invention in 1974. While there have been multiple advances in SAM over the past four decades, some issues still remain to be addressed. First, the measurement speed is limited by the mechanical movement of the acoustic lens. Second, a single element transducer acoustic lens only delivers a predetermined beam pattern for a fixed focal length and incident angle, thereby limiting control of the inspection beam. Here, we propose to develop a phased-array probe as an alternative to overcome these issues. Preliminary studies to design a practical high frequency phased-array acoustic microscope probe were explored. A linear phased-array, comprising 32 elements and operating at 5 MHz, was modeled using PZFlex, a finite-element method software. This phased array system was characterized in terms of electrical input impedance response, pulse-echo and impulse response, surface displacement profiles, mode shapes, and beam profiles. The results are presented in this paper.
引用
收藏
页数:9
相关论文
共 35 条
  • [1] Finite element modeling for ultrasonic transducers
    Abboud, NN
    Wojcik, GL
    Vaughan, DK
    Mould, J
    Powell, DJ
    Nikodym, L
    [J]. ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1998, 1998, 3341 : 19 - 42
  • [2] ATALAR A, 1989, IEEE 1989 ULTRASONICS SYMPOSIUM : PROCEEDINGS, VOLS 1 AND 2, P813, DOI 10.1109/ULTSYM.1989.67100
  • [3] Scanning acoustic microscopy study of human cortical and trabecular bone
    Bumrerraj, S
    Katz, JL
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (12) : 1034 - 1042
  • [4] RESTRICTED APERTURE ACOUSTIC MICROSCOPE LENS FOR RAYLEIGH-WAVE IMAGING
    DAVIDS, DA
    WU, PY
    CHIZHIK, D
    [J]. APPLIED PHYSICS LETTERS, 1989, 54 (17) : 1639 - 1641
  • [5] Endo T., 1993, IEEE ULTRASON INTER, P45
  • [6] Griggio F., 2012, P 2012 IEEE INT ULTR, P1
  • [7] Khuri-Yakub B. T., 1986, IEEE 1986 Ultrasonics Symposium Proceedings (Cat. No.86CH2375-4), P741
  • [8] Kim Jeong Nyeon, 2013, SPIE SMART STRUCTURE
  • [9] NEW EQUIVALENT CIRCUITS FOR ELEMENTARY PIEZOELECTRIC TRANSDUCERS
    KRIMHOLTZ, R
    LEEDOM, DA
    MATTHAEI, GL
    [J]. ELECTRONICS LETTERS, 1970, 6 (13) : 398 - +
  • [10] CALCULATION OF THE ACOUSTIC MATERIAL SIGNATURE OF A LAYERED SOLID
    KUNDU, T
    MAL, AK
    WEGLEIN, RD
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (02) : 353 - 361