Angular variation of scattering volume and its implications for Compton scattering tomography

被引:12
作者
Balogun, FA [1 ]
机构
[1] Obafemi Awolowo Univ, Ctr Energy Res & Dev, Ile Ife, Nigeria
关键词
Compton scattering; volume; field of view; tomography;
D O I
10.1016/S0969-8043(98)00015-3
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
If quantitative and qualitative precision is to be achieved in X-ly-rays Compton scattering densitometry and tomography, the volume of interaction within which a useful signal is collected must be well defined and accurately estimated. This work presents a numerical study of the variation of scattering angles and collimator sizes. The effect of choosing back-scattering angles for measurement in both the densitometry and tomographic modes of this technique is studied. A symmetry is observed between the volume at forward and back scattering angles. A symmetry exists, however, within the scattering angle range 90 +/- 30 degrees. It is proposed that the best volume/spatial resolution in Compton scattering densitometry/tomography is obtainable within the above mentioned scattering angle range. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 11 条
[1]   Energy-spectral compton scatter imaging .2. Experiments [J].
Arendtsz, NV ;
Hussein, EMA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) :2166-2172
[2]   Energy-spectral Compton scatter imaging .1. Theory and mathematics [J].
Arendtsz, NV ;
Hussein, EMA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) :2155-2165
[3]   COMPTON-SCATTERING TOMOGRAPHY IN THE STUDY OF A DENSE INCLUSION IN A LIGHTER MATRIX [J].
BALOGUN, FA ;
SPYROU, NM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (04) :533-538
[4]   COMPTON SCATTER IMAGING OF TRANSVERSE SECTIONS - AN OVERALL APPRAISAL AND EVALUATION FOR RADIOTHERAPY PLANNING [J].
BATTISTA, JJ ;
BRONSKILL, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (01) :81-99
[5]   The photodegradation of some naturally occurring polymers [J].
Davidson, RS .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1996, 33 (01) :3-25
[6]   Low angle X-ray scatter for explosives detection: A geometry optimization [J].
Luggar, RD ;
Horrocks, JA ;
Speller, RD ;
Lacey, RJ .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (02) :215-224
[7]   Monitoring and correction of multiple scatter during clinical Compton scatter densitometry measurements [J].
Mooney, MJ ;
Naga, SSD ;
Speller, RD ;
Koligliatis, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2399-2410
[8]   COMPTON-SCATTERING TOMOGRAPHY [J].
NORTON, SJ .
JOURNAL OF APPLIED PHYSICS, 1994, 76 (04) :2007-2015
[9]  
PRETTYMAN TH, 1993, APPOL RAD ISOT, V41, P327
[10]  
Shrakawa Y., 1996, Memoirs of the Faculty of Engineering, Fukui University, V44, P265