In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring

被引:65
|
作者
Ballerstadt, R
Polak, A
Beuhler, A
Frye, J
机构
[1] BioTex Inc, Houston, TX 77054 USA
[2] Motorola Inc, Northbrook, IL 60062 USA
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 19卷 / 08期
关键词
diabetes; concanavalin A; dextran; sephadex; Alexa dye; fluorophore; regenerated cellulose acetate membrane;
D O I
10.1016/j.bios.2003.08.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Iona-term in vitro performance of a fluorescence affinity sensor for transdermal blood glucose monitoring was investigated. Affinity binding of fluorescently labeled concanavalin A (ConA) was used in this application, as previously described by Ballerstadt and Schultz [Anal. Chem. 17 (2000) 4185-4192]. In this paper, the fluorescence emission of the sensor was extended to the near infrared (670 nm) using Alexa647(TM) as the fluorochrome conjugated to concanavalin A. Sensors were alternately exposed to glucose solutions having concentrations of 2.5 and 20 mM with a dwell time of 3 h. The optical output of the sensors was monitored over a 4-month period. The sensors showed an initial increase in fluorescence over the first 3-4 weeks before gradually decreasing, with an approximately linear drop of 25% per month. In order to understand the reasons for the decrease in fluorescence output, further experiments were conducted, including time-dependent membrane leakage tests. solubility tests of ConA, temperature-dependent activity tests of ConA, and fluorescence photo-bleaching tests. From these results. it became evident that the decrease in fluorescence was not due to denaturation of the ConA. The most likely cause was leakage of the fluorescently labeled ConA through the interface between the outer sealant and the membrane. This problem is considered to be solvable and future publications will address this issue. Extrapolation of the experimental data suggests that a leak-proof sensor would be remarkably stable with a fluorescence decrease of only 15% over a 1-year period. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:905 / 914
页数:10
相关论文
共 50 条
  • [31] Near-infrared fluorescence cholangiography in dogs: A pilot study
    Larose, Philippe Chagnon
    Sanchez, Andrea
    Monteith, Gabrielle
    Singh, Ameet
    Zhang, Michael
    VETERINARY SURGERY, 2024, 53 (01) : 18 - 19
  • [32] Novel near-infrared fluorescence sensor for detection of platelet activation in vivo
    Khanh Ha
    Zheng, Xiaoxin
    Jaffer, Farouc
    Kessinger, Chase
    McCarthy, Jason
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [33] Near-infrared in vivo fluorescence sensor with integrated dielectric emission filter
    O'Sullivan, Thomas D.
    Munro, Elizabeth
    Conca, Christopher
    Parashurama, Natesh
    de la Zerda, Adam
    Gambhir, Sanjiv S.
    Harris, James S.
    Levi, Ofer
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 3085 - +
  • [34] A novel near-infrared fluorescence sensor for detection of thrombin activation in blood
    Tung, CH
    Gerszten, RE
    Jaffer, FA
    Weissleder, R
    CHEMBIOCHEM, 2002, 3 (2-3) : 207 - 211
  • [35] Evaluation of Mobile Phone Performance for Near-Infrared Fluorescence Imaging
    Ghassemi, Pejhman
    Wang, Bohan
    Wang, Jianting
    Wang, Quanzeng
    Chen, Yu
    Pfefer, T. Joshua
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (07) : 1650 - 1653
  • [36] Long-term histological comparison between near-infrared irradiated skin and scar tissues
    Tanaka, Yohei
    Matsuo, Kiyoshi
    Yuzuriha, Shunsuke
    CLINICAL COSMETIC AND INVESTIGATIONAL DERMATOLOGY, 2010, 3 : 143 - 149
  • [37] Near-infrared fluorescence spectroscopy detects Alzheimer's disease in vitro
    Hanlon, EB
    Itzkan, I
    Dasari, RR
    Feld, MS
    Ferrante, RJ
    McKee, AC
    Lathi, D
    Kowall, NW
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1999, 70 (02) : 236 - 242
  • [38] Application of the VSP near-infrared fluorescence probe in hyperlipidemia viscosity monitoring
    Yang, Longyang
    Jin, Chen
    Fang, Ning
    Zhu, Hai-Liang
    Li, Zhen
    MATERIALS TODAY CHEMISTRY, 2023, 34
  • [39] Total thyroidectomy with intraoperative neural monitoring and near-infrared fluorescence imaging
    Diego Barbieri
    Frédéric Triponez
    Pietro Indelicato
    Alessandro Vinciguerra
    Matteo Trimarchi
    Mario Bussi
    Langenbeck's Archives of Surgery, 2021, 406 : 2879 - 2885
  • [40] Upconversion fluorescence monitoring near-infrared during tumor photothermal therapy
    Wei Y.
    Wu B.
    Yang L.
    Xing D.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2010, 37 (11): : 2719 - 2724