Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study

被引:25
作者
Badran, Mohamad Aboelnour [1 ,3 ]
Moemen, Dalia Mohamed [2 ,3 ]
机构
[1] Mansoura Univ, Dept Med Microbiol & Immunol, Mansoura, Egypt
[2] Mansoura Univ, Dept Orthoped & Traumatol, Fac Med, Mansoura, Egypt
[3] Mansoura Univ, Fac Med, Mansoura, Egypt
关键词
ACL; Hamstring; Autograft; Infection; Sterilisation; Contamination; SEPTIC ARTHRITIS; ACL-RECONSTRUCTION; INFECTION; DIAGNOSIS; SURGERY;
D O I
10.1007/s00264-016-3168-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Autograft preparation for anterior cruciate ligament (ACL) reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of bacterial contamination of hamstring autograft during preparation and when dropped onto the operating room floor and methods of graft decontamination. Sixty hamstring tendon autograft specimens were used as the test group. Excess tendon not used in the ACL procedure was divided into five segments. One segment, at the completion of preparation, was sent for culture as a control; the remaining four segments were dropped onto the floor adjacent to the surgical field for 15 seconds. One segment was cultured without undergoing any further treatment. Cultures were taken from each segment after immersion in 10 % povidone-iodine solution, 4 % chlorhexidine and bacitracin, respectively, for three minutes. Cultures of a skin swab and floor swab were taken at the same time and place that the ACL was dropped. Cultures of control graft tissue from ten patients (16.7 %) were positive for bacteria. No patient developed post-operative infection. Ninety organisms were identified, with Staphylococcus epidermidis being the most common isolate. Grafts rinsed in either bacitracin or 4 % chlorhexidine solutions were less likely to be culture positive. A high rate of contamination can be expected during autograft preparation for ACL reconstruction. Soaking the hamstring autograft in either bacitracin or 4 % chlorhexidine solution is effective for decontamination, particulary if graft is dropped on the floor.
引用
收藏
页码:1899 / 1903
页数:5
相关论文
共 23 条
[1]   Multiple arthroscopic debridement and graft retention in septic knee arthritis after ACL reconstruction: a prospective case-control study [J].
Abdel-Aziz, Ahmed ;
Radwan, Yasser A. ;
Rizk, Ahmed .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) :73-82
[2]   The effects of chlorhexidine irrigation solution on contaminated bone-tendon allografts [J].
Burd, T ;
Conroy, BP ;
Meyer, SC ;
Allen, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (02) :241-244
[3]  
COOPER D E, 1991, Arthroscopy, V7, P272, DOI 10.1016/0749-8063(91)90125-H
[4]   Intraoperative bacterial contamination in operations for joint replacement [J].
Davis, N ;
Curry, A ;
Gambhir, AK ;
Panigrahi, H ;
Walker, CRC ;
Wilkins, EGL ;
Worsley, MA ;
Kay, PR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :886-889
[5]   Positive culture in allograft ACL-reconstruction:: what to do? [J].
Díaz-de-Rada, P ;
Barriga, A ;
Barroso, JL ;
García-Barrecheguren, E ;
Alfonso, M ;
Valentí, JR .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (04) :219-222
[6]   Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction [J].
Gavriilidis, Iosif ;
Pakos, Emilios E. ;
Wipfler, Benjamin ;
Benetos, Ioannis S. ;
Paessler, Hans H. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (09) :1043-1047
[7]   Functional outcome of septic arthritis after anterior cruciate ligament surgery [J].
Gille, Justus ;
Gerlach, Ulf ;
Oheim, Ralf ;
Hintze, Thorben ;
Himpe, Bastian ;
Schultz, Arndt-Peter .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) :1195-1201
[8]   Autograft contamination during preparation for anterior cruciate ligament reconstruction [J].
Hantes, Michael E. ;
Basdekis, Georgios K. ;
Varitimidis, Sokratis E. ;
Giotikas, Dimitrios ;
Petinaki, Efthimia ;
Malizos, Konstantinos N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :760-764
[9]   Anterior and posterior cruciate ligament reconstruction in the new millennium: a global perspective [J].
Harner, CD ;
Fu, FH ;
Irrgang, JJ ;
Vogrin, TM .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (06) :330-336
[10]  
Indelli PF, 2002, CLIN ORTHOP RELAT R, P182