Towards Robust Blood Pressure Estimation From Pulse Wave Velocity Measured by Photoplethysmography Sensors

被引:18
作者
Byfield, Richard [1 ]
Miller, Morgan [1 ]
Miles, Jonathan [1 ]
Guidoboni, Giovanna [2 ,3 ]
Lin, Jian [1 ,2 ]
机构
[1] Univ Missouri, Dept Mech & Aerosp Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Dept Elect Engn & Comp Sci, Columbia, MO 65211 USA
[3] Univ Missouri, Dept Math, Columbia, MO 65211 USA
关键词
Sensors; Feature extraction; Electrocardiography; Monitoring; Blood; Pulse measurements; Pressure measurement; Blood pressure; photoplethysmography; pulse wave velocity; machine learning; PPG; RISK; ECG;
D O I
10.1109/JSEN.2021.3134890
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, advances in biosensing devices have greatly increased the ability of sensing human biological vital signs. These advances have allowed physicians to better assess the health status of patients. Among them, blood pressure (BP) sensing has been the dominant one, showing the most potential for growth. Despite much progress, a rapid, robust, and easy-accessed way for BP sensing is still much needed for the emerging point-of-care market. To tackle this challenge, in this paper, we present a BP measurement unit that is developed based on two photoplethysmography (PPG) sensors from which pulse wave velocity (PWV) of blood flow can be derived. A robust time difference of collected two subsequent PPG waveforms between two heartbeats was used to calculate PWV. The systolic and diastolic BPs from 26 participants were estimated by using the derived PWV as the input of machine learning (ML) models. Upon testing multiple ML models, the Gaussian process regressor achieved the highest R-2 score of >0.88 and >0.62 for the systolic BP and diastolic BP, respectively. These R-2 scores are among the best that can be achieved with state-of-art non-invasive BP measurement devices. This work demonstrates that PPG-based sensors for PWV and BP estimation, combined with ML, have a great potential of becoming a complementary way to measure biological vital signs.
引用
收藏
页码:2475 / 2483
页数:9
相关论文
共 50 条
  • [41] Cuff-Less Blood Pressure Estimation From Photoplethysmography via Visibility Graph and Transfer Learning
    Wang, Weinan
    Mohseni, Pedram
    Kilgore, Kevin L.
    Najafizadeh, Laleh
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2075 - 2085
  • [42] Cuffless blood pressure estimation from photoplethysmography using deep convolutional neural network and transfer learning
    Koparir, Hueseyin Murat
    Arslan, Ozkan
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 93
  • [43] Association of Blood Pressure Variability Ratio With Glomerular Filtration Rate Independent of Blood Pressure and Pulse Wave Velocity
    Woodiwiss, Angela J.
    Norton, Gavin R.
    Ben-Dov, Iddo Z.
    Gavish, Benjamin
    Bursztyn, Michael
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2017, 30 (12) : 1177 - 1188
  • [44] Noninvasive continuous blood pressure control by pulse wave velocity
    Lutter, N
    Engl, HG
    Fischer, F
    Bauer, RD
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 124 - 126
  • [45] Arterial Pulse Wave Velocity: Prototype Device Based on Photoplethysmography
    Silva, Diego
    Palma, Joaquin
    Casal, Leonardo
    [J]. ADVANCES IN BIOENGINEERING AND CLINICAL ENGINEERING, VOL 1, SABI 2023, 2024, 106 : 144 - 152
  • [46] Estimation of aortic stiffness by finger photoplethysmography using enhanced pulse wave analysis and machine learning
    Hellqvist, Henrik
    Karlsson, Mikael
    Hoffman, Johan
    Kahan, Thomas
    Spaak, Jonas
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [47] Effects of Amlodipine and Valsartan on Blood Pressure Variability and Pulse Wave Velocity in Hypertensive Patients
    Shi, Rufeng
    Liu, Kai
    Shi, Di
    Liu, Qi
    Chen, Xiaoping
    [J]. AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2017, 353 (01) : 6 - 11
  • [48] The effect of residual stresses on the relation between pulse wave velocity and blood pressure in arteries
    Zhang, Yixing
    Lyu, Wenhan
    Shi, Mingxing
    Ma, Yinji
    Feng, Xue
    [J]. ACTA MECHANICA SINICA, 2023, 39 (09)
  • [49] Blood pressure and pulse wave velocity as metrics for evaluating pathologic ageing of the cardiovascular system
    Nilsson, Peter M.
    Khalili, Payam
    Franklin, Stanley S.
    [J]. BLOOD PRESSURE, 2014, 23 (01) : 17 - 30
  • [50] Improved Blood Pressure Prediction Using Systolic Flow Correction of Pulse Wave Velocity
    Lillie, Jeffrey S.
    Liberson, Alexander S.
    Borkholder, David A.