Long-term outcome after sirolimus-eluting stents versus bare metal stents in patients with Diabetes mellitus: a patient-level meta-analysis of randomized trials

被引:29
|
作者
de Waha, Antoinette [1 ]
Dibra, Alban [1 ]
Kufner, Sebastian [1 ]
Baumgart, Dietrich [2 ]
Sabate, Manel [3 ]
Maresta, Aleardo [4 ]
Schoemig, Albert [1 ]
Kastrati, Adnan [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum, D-80636 Munich, Germany
[2] Preventicum Klin Diagnost, Essen, Germany
[3] Hosp Santa Creu & Sant Pau, Cardiovasc Inst, Barcelona, Spain
[4] S Maria Croci Hosp, Div Cardiol, Intervent Ctr, Ravenna, Italy
关键词
Sirolimus-eluting stents; Bare metal stents; Diabetes mellitus; Mortality; Revascularization; POOLED ANALYSIS; CORONARY REVASCULARIZATION; STANDARD STENT; ATHEROSCLEROSIS; DISEASE; SAFETY;
D O I
10.1007/s00392-010-0278-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although it is widely believed that patients with diabetes mellitus obtain the greatest benefit from drug-eluting stents, convincing evidence on long-term efficacy and safety of these stents is lacking. We performed a meta-analysis of individual patient data from four randomized trials including 583 patients comparing sirolimus eluting with bare metal stents (median follow-up of 4.2 years). These were the only specific trials reporting on drug-eluting stents in diabetic patients. The primary endpoint was the incidence of major cardiac events. The secondary endpoints were all-cause mortality and myocardial infarction as a safety endpoint and target lesion re-intervention as an efficacy endpoint. Stent thrombosis was also evaluated. There was a significant reduction in the overall hazard of major cardiac events (hazard ratio [HR] 0.48, 95% confidence interval [CI] 0.36-0.63, P < 0.001) with sirolimus-eluting stents. This was mostly due to a significant reduction in the overall hazard of repeat revascularization (HR 0.27, 95% CI 0.18-0.41, P < 0.001) in favor of sirolimus-eluting stents. However, the overall hazard of death (HR 0.91, 95% CI 0.59-1.41, P = 0.68) as well as death or myocardial infarction (HR 0.77, 95% CI 0.54-1.09, P = 0.14) were not significantly different between the groups. No significant differences were observed regarding stent thrombosis (HR 0.50, 95% CI 0.15-1.69, P = 0.26). Sirolimus-eluting stents are highly effective in reducing the risk for major cardiac events and safe in diabetic patients with coronary artery disease.
引用
收藏
页码:561 / 570
页数:10
相关论文
共 50 条
  • [21] Long-term cardiovascular outcomes of biodegradable polymer drug eluting stents in patients with diabetes versus non-diabetes mellitus: a meta-analysis
    Hong Wang
    Quannan Zu
    Hairong Tang
    Ming Lu
    Rongfa Chen
    Zhiren Yang
    Cardiovascular Diabetology, 22
  • [22] Zotarolimus-eluting stent versus sirolimus-eluting and paclitaxel-eluting stents for percutaneous coronary intervention: A meta-analysis of randomized trials
    Sethi, Ankur
    Bahekar, Amol
    Bhuriya, Rohit
    Bajaj, Anurag
    Singh, Param Puneet
    Arora, Rohit
    Khosla, Sandeep
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (11) : 544 - 556
  • [23] Five-Year Outcomes in Patients With Diabetes Mellitus Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents
    Iglesias, Juan F.
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Lanz, Jonas
    Rigamonti, Fabio
    Mueller, Olivier
    Moarof, Igal
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Cuculi, Florim
    Valgimigli, Marco
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [24] Oxidative stress changes after stent implantation: A randomized comparative study of sirolimus-eluting and bare metal stents
    Kochiadakis, George E.
    Arfanakis, Dimitris A.
    Marketou, Maria E.
    Skalidis, Emmanuel I.
    Igoumenidis, Nikolaos E.
    Nikitovic, Dragana
    Giaouzaki, Aikaterini
    Chlouverakis, Gregory
    Vardas, Panos E.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 142 (01) : 33 - 37
  • [25] Stent Thrombosis with Biodegradable Polymer Drug-Eluting Stents versus Durable Polymer Sirolimus-Eluting Stents: An Update Meta-Analysis
    Zhu, Lin
    Lv, Yi Ning
    Wang, Li Yu
    CARDIOLOGY, 2015, 130 (02) : 96 - 105
  • [26] Efficacy and safety of zotarolimus-eluting stents compared with sirolimus-eluting stents in patients undergoing percutaneous coronary interventions - A meta-analysis of randomized controlled trials
    Fan, Jinqi
    Du, Huaan
    Yin, Yuehui
    Ling, Zhiyu
    Wu, Jinjin
    Xiao, Peilin
    Zrenner, Bernhard
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) : 2126 - 2133
  • [27] Drug-Eluting Stents Versus Bare-Metal Stents in Patients With Decreased GFR: A Meta-analysis
    Wang, Zhi Jian
    Harjai, Kishore J.
    Shenoy, Chetan
    Gao, Fei
    Shi, Dong Mei
    Liu, Yu Yang
    Zhao, Ying Xin
    Zhou, Yu Jie
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2013, 62 (04) : 711 - 721
  • [28] Long-Term Outcomes of Drug-Eluting Stents Versus Bare-Metal Stents in End-Stage Renal Disease Patients on Dialysis A Systematic Review and Meta-Analysis
    Khera, Sahil
    Villablanca, Pedro A.
    Kolte, Dhaval
    Gupta, Tanush
    Khan, Mohammed Hasan
    Velagapudi, Poonam
    Kalra, Ankur
    Kleiman, Neal
    Aronow, Herbert D.
    Abbott, J. Dawn
    Rosenfield, Kenneth
    Drachman, Douglas E.
    Bangalore, Sripal
    Bhatt, Deepak L.
    Naidu, Srihari S.
    CARDIOLOGY IN REVIEW, 2018, 26 (06) : 277 - 286
  • [29] Long-term clinical impact of polymer-free sirolimus-eluting stents in unselected patients
    Sinha, Nakul
    Rai, Himanshu
    Cassese, Salvatore
    Kumar, Sudeep
    Kapoor, Aditya
    Kastrati, Adnan
    CORONARY ARTERY DISEASE, 2016, 27 (05) : 385 - 390
  • [30] Long-term outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer everolimus-eluting stents: A meta-analysis of randomized controlled trials
    Sakurai, Ryota
    Burazor, Ivana
    Bonneau, Heidi N.
    Kaneda, Hideaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 1066 - 1071