Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma

被引:30
作者
De Smet, E. [1 ]
De Praeter, G. [2 ]
Verstraete, K. L. A. [3 ]
Wouters, K. [4 ]
De Beuckeleer, Luc [5 ]
Vanhoenacker, F. M. H. M. [1 ,2 ,3 ]
机构
[1] Univ Antwerp Hosp, Dept Radiol, B-2650 Edegem, Belgium
[2] Sint Maartenziekenhuis, Dept Radiol, B-2570 Duffel, Belgium
[3] Ghent Univ Hosp, Dept Radiol, B-9000 Ghent, Belgium
[4] Univ Antwerp Hosp, Dept Sci Coordinat & Biostat, B-2650 Edegem, Belgium
[5] GZA Sint Augustinus, Dept Radiol, B-2610 Antwerp, Belgium
关键词
Trauma; Imaging modalities; Cone-beam CT; Digital radiography; DIGITAL VOLUME TOMOGRAPHY; COMPUTED-TOMOGRAPHY; WRIST; REDUCTION; HAND;
D O I
10.1007/s00256-015-2127-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To compare the diagnostic value of cone-beam computed tomography (CBCT) and conventional radiography (CR) after acute small bone or joint trauma. Materials and methods Between March 2013 and January 2014, 231 patients with recent small bone or joint trauma underwent CR and subsequent CBCT. CR and CBCT examinations were independently assessed by two readers, blinded to the result of the other modality. The total number of fractures as well as the number of complex fractures were compared, and inter- and intraobserver agreement for CBCT was calculated. In addition, radiation doses and evaluation times for both modalities were noted and statistically compared. Results Fracture detection on CBCT increased by 35 % and 37 % for reader 1 and reader 2, respectively, and identification of complex fractures increased by 236 % and 185 %. Interobserver agreement for CBCT was almost perfect, as was intraobserver agreement for reader 1. The intraobserver agreement for reader 2 was substantial. Radiation doses and evaluation time were significantly higher for CBCT. Conclusion CBCT detects significantly more small bone and joint fractures, in particular complex fractures, than CR. In the majority of cases, the clinical implication of the additionally detected fractures is limited, but in some patients (e.g., fracture-dislocations), the management is significantly influenced by these findings. As the radiation dose for CBCT substantially exceeds that of CR, we suggest adhering to CR as the first-line examination after small bone and joint trauma and keeping CBCT for patients with clinical-radiographic discordance or suspected complex fractures in need of further (preoperative) assessment.
引用
收藏
页码:1111 / 1117
页数:7
相关论文
共 19 条
[1]   Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[2]   Value of digital volume tomography in patients with conductive hearing loss [J].
Dalchow, CV ;
Weber, AL ;
Bien, S ;
Yanagihara, N ;
Werner, JA .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (02) :92-99
[3]   Digital volume tomography: Radiologic examinations of the temporal bone [J].
Dalchow, CV ;
Weber, AL ;
Yanagihara, N ;
Bien, S ;
Werner, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) :416-423
[4]   Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique [J].
De Cock, Jens ;
Mermuys, Koen ;
Goubau, Jean ;
Van Petegem, Simon ;
Houthoofd, Brecht ;
Casselman, Jan W. .
SKELETAL RADIOLOGY, 2012, 41 (01) :93-96
[5]  
De Groote J, 2014, JBR-BTR, V97, P270
[6]   Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography [J].
Faccioli, Niccolo ;
Foti, Giovanni ;
Barillari, Marco ;
Atzei, Andrea ;
Mucelli, Roberto Pozzi .
SKELETAL RADIOLOGY, 2010, 39 (11) :1087-1095
[7]  
FELDKAMP LA, 1988, IEEE T MED IMAGING, V7, P73, DOI 10.1109/42.3930
[8]   State-of-the-art on cone beam CT imaging for preoperative planning of implant placement [J].
Guerrero, ME ;
Jacobs, R ;
Loubele, M ;
Schutyser, F ;
Suetens, P ;
van Steenberghe, D .
CLINICAL ORAL INVESTIGATIONS, 2006, 10 (01) :1-7
[9]   Usefulness of Cone-Beam CT Before and After Percutaneous Vertebroplasty [J].
Hiwatashi, Akio ;
Yoshiura, Takashi ;
Noguchi, Tomoyuki ;
Togao, Osamu ;
Yamashita, Koji ;
Kamano, Hironori ;
Honda, Hiroshi .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) :1401-1405
[10]   CT arthrography of the wrist using a novel, mobile, dedicated extremity cone-beam CT (CBCT) [J].
Koskinen, Seppo K. ;
Haapamaki, Ville V. ;
Salo, Jari ;
Lindfors, Nina C. ;
Kortesniemi, Mika ;
Seppala, Lauri ;
Mattila, Kimmo T. .
SKELETAL RADIOLOGY, 2013, 42 (05) :649-657