Indoor air quality in elementary schools of Lisbon in spring

被引:103
作者
Pegas, P. N. [1 ]
Alves, C. A. [1 ]
Evtyugina, M. G. [1 ]
Nunes, T. [1 ]
Cerqueira, M. [1 ]
Franchi, M. [1 ]
Pio, C. A. [1 ]
Almeida, S. M. [2 ]
Freitas, M. C. [2 ]
机构
[1] Univ Aveiro, Dept Environm, Ctr Environm & Marine Studies, P-3810193 Aveiro, Portugal
[2] Nucl & Technol Inst, P-2686953 Sacavem, Portugal
关键词
Carbon dioxide; Carbon monoxide; Carbonyls; Indoor air quality; Nitrogen dioxide; Schools; Volatile organic compounds; VOLATILE ORGANIC-COMPOUNDS; CARBON-MONOXIDE; RESPIRATORY SYMPTOMS; NITROGEN-DIOXIDE; HEALTH SYMPTOMS; OUTDOOR; ENVIRONMENTS; FORMALDEHYDE; EMISSIONS; VENTILATION;
D O I
10.1007/s10653-010-9345-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Analysis of indoor air quality (IAQ) in schools usually reveals higher levels of pollutants than in outdoor environments. The aims of this study are to measure indoor and outdoor concentrations of NO2, speciated volatile organic compounds (VOCs) and carbonyls at 14 elementary schools in Lisbon, Portugal. The investigation was carried out in May-June 2009. Three of the schools were selected to also measure comfort parameters, such as temperature and relative humidity, carbon dioxide (CO2), carbon monoxide (CO), total VOCs, and bacterial and fungal colony-forming units per cubic metre. Indoor concentrations of CO2 in the three main schools indicated inadequate classroom air exchange rates. The indoor/outdoor (I/O) NO2 ratio ranged between 0.36 and 0.95. At the three main schools, the total bacterial and fungal colony-forming units (CFU) in both indoor and outdoor air were above the advised maximum value of 500 CFU/m(3) defined by Portuguese legislation. The aromatic compounds benzene, toluene, ethylbenzene and xylenes, followed by ethers, alcohols and terpenes, were usually the most abundant classes of VOCs. In general, the indoor total VOC concentrations were markedly higher than those observed outdoors. At all locations, indoor aldehyde levels were higher than those observed outdoors, particularly for formaldehyde. The inadequate ventilation observed likely favours accumulation of pollutants with additional indoor sources.
引用
收藏
页码:455 / 468
页数:14
相关论文
共 65 条
[1]  
[Anonymous], 1987, AIR QUALITY GUIDELIN
[2]  
[Anonymous], 2005, AIR QUALITY GUIDELIN
[3]  
*ANSI ASHRAE, 1999, 621999 ANSIASHRAE IN
[4]  
*ANSI ASHRAE, 2004, 552004 ANSIASHRAE IN
[5]   Variability of NO2 in different environments at a moderately polluted island over the southwestern Indian Ocean [J].
Bhugwant, C ;
Hoareau, JL .
ATMOSPHERIC RESEARCH, 2003, 66 (04) :241-259
[6]   Relationship between outdoor and indoor air quality in eight French schools [J].
Blondeau, P ;
Iordache, V ;
Poupard, O ;
Genin, D ;
Allard, F .
INDOOR AIR, 2005, 15 (01) :2-12
[7]   Impact of road traffic emissions on air quality of the Lisbon region [J].
Borrego, C ;
Tchepel, O ;
Barros, N ;
Miranda, AI .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (27) :4683-4690
[8]   Monitoring of volatile organic compounds in non-residential indoor environments [J].
Bruno, P. ;
Caselli, M. ;
de Gennaro, G. ;
Iacobellis, S. ;
Tutino, M. .
INDOOR AIR, 2008, 18 (03) :250-256
[9]   Indoor and outdoor carbon monoxide concentration relationships at different microenvironments in the Athens area [J].
Chaloulakou, A ;
Mavroidis, I ;
Duci, A .
CHEMOSPHERE, 2003, 52 (06) :1007-1019
[10]   Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools [J].
Chew, GL ;
Correa, JC ;
Perzanowski, MS .
INDOOR AIR, 2005, 15 (04) :228-234