Automatic determination of the arterial input function in dynamic susceptibility contrast MRI: comparison of different reproducible clustering algorithms

被引:11
作者
Yin, Jiandong [1 ]
Yang, Jiawen [1 ]
Guo, Qiyong [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang 110004, Peoples R China
关键词
Affine propagation; Arterial input function; Cerebral perfusion; Normalized cut; CEREBRAL-BLOOD-FLOW; SINGULAR-VALUE DECOMPOSITION; ENHANCED MRI; PERFUSION MRI; BLIND DECONVOLUTION; BOLUS-TRACKING; QUANTIFICATION; STROKE; HYPERACUTE; SELECTION;
D O I
10.1007/s00234-015-1493-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Arterial input function (AIF) plays an important role in the quantification of cerebral hemodynamics. The purpose of this study was to select the best reproducible clustering method for AIF detection by comparing three algorithms reported previously in terms of detection accuracy and computational complexity. First, three reproducible clustering methods, normalized cut (Ncut), hierarchy (HIER), and fast affine propagation (FastAP), were applied independently to simulated data which contained the true AIF. Next, a clinical verification was performed where 42 subjects participated in dynamic susceptibility contrast MRI (DSC-MRI) scanning. The manual AIF and AIFs based on the different algorithms were obtained. The performance of each algorithm was evaluated based on shape parameters of the estimated AIFs and the true or manual AIF. Moreover, the execution time of each algorithm was recorded to determine the algorithm that operated more rapidly in clinical practice. In terms of the detection accuracy, Ncut and HIER method produced similar AIF detection results, which were closer to the expected AIF and more accurate than those obtained using FastAP method; in terms of the computational efficiency, the Ncut method required the shortest execution time. Ncut clustering appears promising because it facilitates the automatic and robust determination of AIF with high accuracy and efficiency.
引用
收藏
页码:535 / 543
页数:9
相关论文
共 39 条
  • [1] New Criterion to Aid Manual and Automatic Selection of the Arterial Input Function in Dynamic Susceptibility Contrast MRI
    Bleeker, Egbert J. W.
    van Osch, Matthias J. P.
    Connelly, Alan
    van Buchem, Mark A.
    Webb, Andrew G.
    Calamante, Fernando
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 448 - 456
  • [2] Optimal location for arterial input function measurements near the middle cerebral artery in first-pass perfusion MRI
    Bleeker, Egbert J. W.
    van Buchem, Mark A.
    van Osch, Matthias J. P.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 (04) : 840 - 852
  • [3] Defining a local arterial input function for perfusion MRI using independent component analysis
    Calamante, F
    Morup, M
    Hansen, LK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 789 - 797
  • [4] Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization
    Calamante, F
    Gadian, DG
    Connelly, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) : 1237 - 1247
  • [6] Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging
    Carroll, TJ
    Rowley, HA
    Haughton, VM
    [J]. RADIOLOGY, 2003, 227 (02) : 593 - 600
  • [7] Arterial input functions for dynamic susceptibility contrast MRI: Requirements and signal options
    Conturo, TE
    Akbudak, E
    Kotys, MS
    Chen, ML
    Chun, SJ
    Hsu, RM
    Sweeney, CC
    Markham, J
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (06) : 697 - 703
  • [8] Quantitative assessment of regional cerebral blood flow by dynamic susceptibility contrast-enhanced MRI, without the need for arterial blood signals
    Enmi, Jun-ichiro
    Kudomi, Nobuyuki
    Hayashi, Takuya
    Yamamoto, Akihide
    Iguchi, Satoshi
    Moriguchi, Tetsuaki
    Hori, Yuki
    Koshino, Kazuhiro
    Zeniya, Tsutomu
    Shah, Nadim Jon
    Yamada, Naoaki
    Iida, Hidehiro
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23) : 7873 - 7892
  • [9] What is the best similarity measure for motion correction in fMRI time series?
    Freire, L
    Roche, A
    Mangin, JF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (05) : 470 - 484
  • [10] Motion correction algorithms may create spurious brain activations in the absence of subject motion
    Freire, L
    Mangin, JF
    [J]. NEUROIMAGE, 2001, 14 (03) : 709 - 722