Three-phase dynamic breast magnetic resonance imaging with two-way subtraction

被引:12
作者
Choi, N [1 ]
Han, BK [1 ]
Choe, YH [1 ]
Kim, HS [1 ]
机构
[1] Sungkyunkwan Univ, Dept Diagnost Radiol, Samsung Med Ctr, Sch Med, Seoul 135710, South Korea
关键词
breast; diagnosis; MRI;
D O I
10.1097/01.rct.0000181722.84844.9c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was undertaken to introduce a new breast magnetic resonance (MR) imaging technique, 3-phase dynamic MR imaging with 2-way subtraction, and to examine the morphologic and kinetic features of malignant and benign breast lesions using this technique. Methods: In 99 breasts from 89 consecutive women with suspicious breast lesions (age range: 32-72 years, mean = 48.2 years), MR imaging was performed using a fat-saturated, sagittal, gradient-echo sequence in 3 phases (1 precontrast and 2 postcontrast scans). Two-way subtraction was performed: standard subtraction (early postcontrast minus precontrast scans) and reverse subtraction (early postcontrast minus late postcontrast scans). A radiologist interpreted all the images, described the breast lesions (using the Breast Imaging Reporting and Data System MR lexicon), and assessed the lesions prospectively as being benign or malignant. The lesions with at least I malignant feature were classified as malignant. The MR classifications were compared with the biopsy or follow-up results. Results: Sixty-five (65.7%) breast lesions were malignant, and 34 (34.3%) were benign. Forty-two (97.7%) of the 43 cases of micro-invasive or invasive ductal cancer showed malignant morphologic features, and 38 (88.4%) showed washout kinetics. Eighteen (81.8%) of the 22 cases of ductal carcinoma in situ showed malignant morphologic features, and 11 (50.0%) showed washout kinetics. Twenty-nine (85.3%) of the 34 benign lesions showed neither malignant morphologic features nor washout kinetics. The sensitivity and specificity were 92.3% and 91.2% by morphologic analysis and 93.8% and 85.3% by the combined method (morphology plus kinetic analysis), respectively. Conclusions: This study demonstrated that 3-phase dynamic breast MR imaging with 2-way subtraction and a maximum intensity projection (MIP) image is a simple and useful technique for identifying breast lesions. Although the addition of the kinetic criteria enhanced the sensitivity at the cost of specificity, radiologists can diagnose a malignant lesion showing non-mass-like enhancement more confidently using reverse subtraction imaging. Therefore, this study proposes 3-phase dynamic imaging with 2-way subtraction and an MIP image as one of the standard protocols of breast MR imaging.
引用
收藏
页码:834 / 841
页数:8
相关论文
共 20 条
[11]  
Kuhl CK, 2000, J MAGN RESON IMAGING, V12, P965, DOI 10.1002/1522-2586(200012)12:6<965::AID-JMRI23>3.0.CO
[12]  
2-1
[13]   Breast lesions detected on MR imaging: Features and positive predictive value [J].
Liberman, L ;
Morris, EA ;
Lee, MJY ;
Kaplan, JB ;
LaTrenta, LR ;
Menell, JH ;
Abramson, AF ;
Dashnaw, SM ;
Ballon, DJ ;
Dershaw, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (01) :171-178
[14]   Illustrated breast MR lexicon [J].
Morris, EA .
SEMINARS IN ROENTGENOLOGY, 2001, 36 (03) :238-249
[15]   Breast MB imaging: Interpretation model [J].
Nunes, LW ;
Schnall, MD ;
Orel, SG ;
Hochman, MG ;
Langlotz, CP ;
Reynolds, CA ;
Torosian, MH .
RADIOLOGY, 1997, 202 (03) :833-841
[16]   MR imaging of the breast for the detection, diagnosis, and staging of breast cancer [J].
Orel, SG ;
Schnall, MD .
RADIOLOGY, 2001, 220 (01) :13-30
[17]   Differentiating benign from malignant enhancing lesions identified at MR imaging of the breast: Are time-signal intensity curves an accurate predictor? [J].
Orel, SG .
RADIOLOGY, 1999, 211 (01) :5-7
[18]   SUSPICIOUS BREAST-LESIONS - MR-IMAGING WITH RADIOLOGIC-PATHOLOGICAL CORRELATION [J].
OREL, SG ;
SCHNALL, MD ;
LIVOLSI, VA ;
TROUPIN, RH .
RADIOLOGY, 1994, 190 (02) :485-493
[19]  
Schnall M D, 2001, Magn Reson Imaging Clin N Am, V9, P289
[20]   Differentiation between benign and malignant findings on MR-mammography:: usefulness of morphological criteria [J].
Wedegärtner, U ;
Bick, U ;
Wörtler, K ;
Rummeny, E ;
Bongartz, G .
EUROPEAN RADIOLOGY, 2001, 11 (09) :1645-1650