Block matching sparsity regularization-based image reconstruction for incomplete projection data in computed tomography

被引:6
作者
Cai, Ailong [1 ]
Li, Lei [1 ]
Zheng, Zhizhong [1 ]
Zhang, Hanming [1 ]
Wang, Linyuan [1 ]
Hu, Guoen [1 ]
Yan, Bin [1 ]
机构
[1] Natl Digital Switching Syst Engn & Technol Res Ct, Zhengzhou 450002, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
computed tomography; image reconstruction; block matching sparsity regularization; proximal point algorithm; projection onto convex set; RAY CT RECONSTRUCTION; IMPLEMENTATION; TRANSFORM;
D O I
10.1088/1361-6560/aa9e63
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In medical imaging many conventional regularization methods, such as total variation or total generalized variation, impose strong prior assumptions which can only account for very limited classes of images. A more reasonable sparse representation frame for images is still badly needed. Visually understandable images contain meaningful patterns, and combinations or collections of these patterns can be utilized to form some sparse and redundant representations which promise to facilitate image reconstructions. In this work, we propose and study block matching sparsity regularization (BMSR) and devise an optimization program using BMSR for computed tomography (CT) image reconstruction for an incomplete projection set. The program is built as a constrained optimization, minimizing the L1-norm of the coefficients of the image in the transformed domain subject to data observation and positivity of the image itself. To solve the program efficiently, a practical method based on the proximal point algorithm is developed and analyzed. In order to accelerate the convergence rate, a practical strategy for tuning the BMSR parameter is proposed and applied. The experimental results for various settings, including real CT scanning, have verified the proposed reconstruction method showing promising capabilities over conventional regularization.
引用
收藏
页数:19
相关论文
共 42 条
  • [1] SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM
    ANDERSEN, AH
    KAK, AC
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 81 - 94
  • [2] [Anonymous], 2008, Computed tomography: from photonstatistics to modern cone-beam CT
  • [3] Total Generalized Variation
    Bredies, Kristian
    Kunisch, Karl
    Pock, Thomas
    [J]. SIAM JOURNAL ON IMAGING SCIENCES, 2010, 3 (03): : 492 - 526
  • [4] Stable signal recovery from incomplete and inaccurate measurements
    Candes, Emmanuel J.
    Romberg, Justin K.
    Tao, Terence
    [J]. COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 2006, 59 (08) : 1207 - 1223
  • [5] Chartrand R, 2013, CONF REC ASILOMAR C, P665, DOI 10.1109/ACSSC.2013.6810365
  • [6] Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    Chen, Guang-Hong
    Tang, Jie
    Leng, Shuai
    [J]. MEDICAL PHYSICS, 2008, 35 (02) : 660 - 663
  • [7] Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm
    Chen, Guang-Hong
    Theriault-Lauzier, Pascal
    Tang, Jie
    Nett, Brian
    Leng, Shuai
    Zambelli, Joseph
    Qi, Zhihua
    Bevins, Nicholas
    Raval, Amish
    Reeder, Scott
    Rowley, Howard
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) : 907 - 923
  • [8] A limited-angle CT reconstruction method based on anisotropic TV minimization
    Chen, Zhiqiang
    Jin, Xin
    Li, Liang
    Wang, Ge
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07) : 2119 - 2141
  • [9] Dabov K, 2007, IEEE INT C IM PROC T
  • [10] Dabov K., 2007, INT TICSP WORKSH SPE