A field survey of visual comfort and lighting energy consumption in open plan offices

被引:92
作者
Yun, Geun Young [1 ]
Kong, Hyo Joo [1 ]
Kim, Hyoin [1 ]
Kim, Jeong Tai [1 ]
机构
[1] Kyung Hee Univ, Dept Architectural Engn, Yongin 446701, South Korea
基金
新加坡国家研究基金会;
关键词
Visual comfort; Lighting energy; Field study; Occupant behaviour; Lighting use pattern; BLINDS; KOREA; MODEL;
D O I
10.1016/j.enbuild.2011.10.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Occupants of buildings consciously interact with environmental systems to satisfy their specific needs for comfort. Field investigations have indicated that this adaptive behaviour of the occupants is a key factor in affecting the energy consumption of buildings and can change the energy use of similar buildings by a factor of 2. This study aims to reveal the factors in determining lighting energy consumption of open plan offices with the emphasis on the roles of occupant adaptive actions. Field investigations of open plan offices in Seoul, Korea were conducted from 20 July to 29 September. Internal and external illuminance and the use of lighting were monitored at ten minute intervals. Seventy seven office workers filled in the questionnaire survey forms five times a day for 40 days. Results reveal that there were close relationships between prevailing illuminance levels on the work plane and luminous comfort. This study presents the hourly profiles of both lighting use patterns and lighting energy consumption, and investigates the lighting energy consumption of open plan offices in relation to internal illuminance, visual comfort and lighting system use patterns. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 151
页数:6
相关论文
共 17 条
[1]  
CIE, 2001, CIE PUBL, V142-2001
[2]   Quantifying energy savings in daylight responsive systems: The role of dimming electronic ballasts [J].
Doulos, L. ;
Tsangrassoulis, A. ;
Topalis, F. .
ENERGY AND BUILDINGS, 2008, 40 (01) :36-50
[3]  
Hosmer W., 2000, Applied Logistic Regression, VSecond
[4]   The dark side of occupants' behaviour on building energy use [J].
Masoso, O. T. ;
Grobler, L. J. .
ENERGY AND BUILDINGS, 2010, 42 (02) :173-177
[5]   Using field measurements of desktop illuminance in European offices to investigate its dependence on outdoor conditions and its effect on occupant satisfaction, and the use of lights and blinds [J].
Nicol, F ;
Wilson, M ;
Chiancarella, C .
ENERGY AND BUILDINGS, 2006, 38 (07) :802-813
[6]   Derivation of the adaptive equations for thermal comfort in free-running buildings in European standard EN15251 [J].
Nicol, Fergus ;
Humphreys, Michael .
BUILDING AND ENVIRONMENT, 2010, 45 (01) :11-17
[7]  
Norford L.K., 2009, ENERG BUILDINGS, V41, P897
[8]  
Reinhart C F., 2003, Lighting Research and Technology, V35, P243, DOI [DOI 10.1191/1365782803LI064OA, 10.1191/1365782803li064oa]
[9]   Lightswitch-2002: a model for manual and automated control of electric lighting and blinds [J].
Reinhart, CF .
SOLAR ENERGY, 2004, 77 (01) :15-28
[10]   Criteria for energy efficient lighting in buildings [J].
Ryckaert, Wouter R. ;
Lootens, Catherine ;
Geldof, Jonas ;
Hanselaer, Peter .
ENERGY AND BUILDINGS, 2010, 42 (03) :341-347