Multicenter biometry study of 1 pair of eyes

被引:16
作者
Norrby, S [1 ]
机构
[1] Pharmacia, NL-9728 NX Groningen, Netherlands
关键词
D O I
10.1016/S0886-3350(01)00857-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the accuracy of biometry for intraocular lens (IOL) power calculation. Setting: Six ophthalmic surgery centers in Europe and 1 in the United States. Methods: Biometry was done as if in preparation for cataract surgery in 2 eyes of the same person with 10 combinations of operator and instrument. Data analysis followed a standardized procedure to assess repeatability (within-center variability) and reproducibility (between-center variability) of the test methods. Results: The reproducibility of the corneal radius measurement was 0.06 mm. The use of different keratometric indices made conversion to K-values less reliable. The repeatability of the axial length (AL) measurement of 0.30 mm and the reproducibility of 0.66 mm converted to a calculated IOL power of 0.75 diopter (D) and 1.65 D, respectively. Thus, this potential patient runs the risk of a refractive surprise of up to 1.10 D purely as a result of a measurement error within a center and up to 2.30 D if the patient goes to the worst-case center. Conclusions: The biometry results show that the measured corneal radius can be used with confidence. Reproducibility errors in AL determination require personalization of formula constants or correction at the source by proper calibration. (C) 2001 ASCRS and ESCRS.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 11 条
[1]  
[Anonymous], 1999, 1197921999 ISO
[2]  
Haigis W, 1995, AUGENARZTLICHE UNTER, P255
[3]   Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations [J].
Holladay, JT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1356-1370
[4]  
ISO, 1986, 5725 ISO
[5]   BIOMETRY OF THE POSTERIOR LENS CAPSULE - A NEW METHOD TO PREDICT PSEUDOPHAKIC ANTERIOR-CHAMBER DEPTH [J].
NAESER, K ;
BOBERGANS, J ;
BARGUM, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (02) :202-206
[6]  
Norrby NES, 1996, J CATARACT REFR SURG, V22, P983
[7]   Determining the imaging quality of intraocular lenses [J].
Norrby, NES ;
Grossman, LW ;
Geraghty, EP ;
Kreiner, CF ;
Mihori, M ;
Patel, AS ;
Portney, V ;
Silberman, DM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05) :703-714
[8]   Unfortunate discrepancies [J].
Norrby, NES .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (04) :433-433
[9]   INTRAOCULAR-LENS POWER CALCULATION WITH AN IMPROVED ANTERIOR-CHAMBER DEPTH PREDICTION ALGORITHM [J].
OLSEN, T ;
CORYDON, L ;
GIMBEL, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (03) :313-319
[10]   ON THE CALCULATION OF POWER FROM CURVATURE OF THE CORNEA [J].
OLSEN, T .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1986, 70 (02) :152-154