Optimal Sizing of a Vanadium Redox Battery System for Microgrid Systems

被引:151
作者
Nguyen, Tu A. [1 ]
Crow, Mariesa L. [1 ]
Elmore, Andrew Curtis [2 ]
机构
[1] Missouri Univ Sci & Technol, Dept Elect & Comp Engn, Rolla, MO 65401 USA
[2] Missouri Univ Sci & Technol, Dept Geol Engn, Rolla, MO 65401 USA
基金
美国国家科学基金会;
关键词
Energy storage; optimal scheduling; optimal sizing; microgrids; renewable energy; vanadium redox battery (VRB); ENERGY-STORAGE SYSTEM; PERFORMANCE CHARACTERIZATION; FLOW BATTERY;
D O I
10.1109/TSTE.2015.2404780
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The vanadium redox battery (VRB) has proven to be a reliable and highly efficient energy storage system (ESS) for microgrid applications. However, one challenge in designing a microgrid system is specifying the size of the ESS. This selection is made more complex due to the independent power and energy ratings inherent in VRB systems. Sizing a VRB for both required power output and energy storage capacity requires an indepth analysis to produce both optimal scheduling capabilities and minimum capital costs. This paper presents an analytical method to determine the optimal ratings of VRB energy storage based on an optimal scheduling analysis and cost-benefit analysis for microgrid applications. A dynamic programming (DP) algorithm is used to solve the optimal scheduling problem considering the efficiency and operating characteristics of the VRBs. The proposed method has been applied to determine the optimal VRB power and energy ratings for both isolated and grid-connected microgrids, which contain PV arrays and fossil-fuel-based generation. We first consider the case in which a grid-tie is not available and diesel generation is the backup source of power. The method is then extended to consider the case in which a utility grid tie is available.
引用
收藏
页码:729 / 737
页数:9
相关论文
共 23 条
[1]   A new approach for optimal sizing of battery energy storage system for primary frequency control of islanded Microgrid [J].
Aghamohammadi, Mohammad Reza ;
Abdolahinia, Hajar .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 54 :325-333
[2]  
AK Attorney General, 2009, RUR FUEL PRIC AL
[3]  
[Anonymous], 2013, Power generation, operation, and control
[4]  
[Anonymous], 2003, SAND20032783 SAND NA
[5]  
[Anonymous], 2010, Sustainable forward operating bases
[6]  
[Anonymous], EL POW MONTHL
[7]   Optimum sizing of battery-integrated diesel generator for remote electrification through design-space approach [J].
Arun, P. ;
Banerjee, Rangan ;
Bandyopadhyay, Santanu .
ENERGY, 2008, 33 (07) :1155-1168
[8]   Reliability-Constrained Optimal Sizing of Energy Storage System in a Microgrid [J].
Bahramirad, Shaghayegh ;
Reder, Wanda ;
Khodaei, Amin .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) :2056-2062
[9]   Methodology for optimally sizing the combination of a battery bank and PV array in a Wind/PV hybrid system [J].
Borowy, BS ;
Salameh, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (02) :367-373
[10]   Sizing of Energy Storage for Microgrids [J].
Chen, S. X. ;
Gooi, H. B. ;
Wang, M. Q. .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (01) :142-151