摘要
Study Design: Prospective case study. Purpose: Osteoporotic spine fixation by pedicle screw instrumentation is complicated by screw loosening, migration, or pullout with rates of up to 62% documented in the literature. Contemporary solutions have not adequately addressed these complications. We propose a modified surgical technique of cement augmentation with bicortical pedicle screw fixation to address the issue related to implant failure in osteoporotic spine. Overview of Literature: Zindrick and his colleagues described a "windshield wiper" effect owing to the shift of center of rotation to the distal tip of the screw in the bicortical purchase of screws. An increase in pullout strength from 119% to 250% with polymethyl methacrylate augmentation has been documented in the literature. This technique has not been described in the literature. Methods: A prospective study was conducted with 40 patients who underwent surgery by the modified technique. Intraoperative and postoperative complications directly related to the procedure were assessed. Improvement in pain and functional status were assessed. Follow-up radiographs were assessed to check for appreciable screw migration, loosening, or pullout. Results: This technique was used in inserting 364 screws in 40 patients. We did not encounter any difficulty in inserting the screws. A total of 19 screws failed to breach the anterior cortex owing to an error in measurement. There were no complications during the procedure in any of the patients, and the postoperative period was uneventful. The mean follow-up period was 18 months. There were two patients in whom proximal junctional failure with kyphosis was noted during follow-up, who were surgically managed by extension of the fixation levels. Conclusions: Bicortical fixation with cement augmentation is a technically feasible, safe, and effective technique to augment the strength of pedicle screws in osteoporotic spine fixation. It has the potential to be established as a standard of care in osteoporotic spine fixation.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 30 条
  • [1] Double pedicle screw instrumentation in the osteoporotic spine - A biomechanical feasibility study
    Jiang, Liang
    Arlet, Vincent
    Beckman, Lorne
    Steffen, Thomas
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (06): : 430 - 435
  • [2] Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    ASIAN SPINE JOURNAL, 2021, 15 (05) : 566 - 574
  • [3] COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY
    AMIOT, LP
    LABELLE, H
    DEGUISE, JA
    SATI, M
    BRODEUR, P
    RIVARD, CH
    SPINE, 1995, 20 (10) : 1208 - 1212
  • [4] Pedicle screw fixation of the thoracic spine:: An in vitro biomechanical study on different configurations
    Deviren, V
    Acaroglu, E
    Lee, J
    Fujita, M
    Hu, S
    Lenke, LG
    Polly, D
    Kuklo, TR
    O'Brien, M
    Brumfield, D
    Puttlitz, CM
    SPINE, 2005, 30 (22) : 2530 - 2537
  • [5] Reinforcement of Percutaneous Pedicle Screw Fixation with Hydroxyapatite Granules in Patients with Osteoporotic Spine: Biomechanical Performance and Clinical Outcomes
    Kanno, Haruo
    Onoda, Yoshito
    Hashimoto, Ko
    Aizawa, Toshimi
    Ozawa, Hiroshi
    MEDICINA-LITHUANIA, 2022, 58 (05):
  • [6] A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws
    Wu, Zi-xiang
    Gong, Fu-tai
    Liu, Li
    Ma, Zhen-sheng
    Zhang, Yang
    Zhao, Xiong
    Yang, Min
    Lei, Wei
    Sang, Hong-xun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (04) : 471 - 476
  • [7] A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws
    Zi-xiang Wu
    Fu-tai Gong
    Li Liu
    Zhen-sheng Ma
    Yang Zhang
    Xiong Zhao
    Min Yang
    Wei Lei
    Hong-xun Sang
    Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 471 - 476
  • [8] Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique
    Boachie-Adjei, O
    Girardi, FP
    Bansal, M
    Rawlins, BA
    JOURNAL OF SPINAL DISORDERS, 2000, 13 (06): : 496 - 500
  • [9] Robotic spine systems: overcoming surgeon experience in pedicle screw accuracy: a prospective study
    Kanhangad, Madhava Pai
    Srinivasa, Vidyadhara
    Thirugnanam, Balamurugan
    Soni, Abhishek
    Kashyap, Anjana
    Vidyadhara, Alia
    Rao, Sharath Kumar
    ASIAN SPINE JOURNAL, 2024, 18 (05) : 663 - 672
  • [10] Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography - A prospective study of 35 patients
    Sapkas, GS
    Papadakis, SA
    Stathakopoulos, DP
    Papagelopoulos, PJ
    Badekas, AC
    Kaiser, JH
    SPINE, 1999, 24 (18) : 1926 - 1929