Hot particle dosimetry at nuclear power plants

被引:0
作者
Bakali, M [1 ]
Fernández, F [1 ]
Bouassoule, T [1 ]
Castelo, J [1 ]
Gonzalez, A [1 ]
机构
[1] Univ Autonoma Barcelona, Grp Fis Radiac, Bellaterra 08193, Spain
关键词
beta dosimetry; thermoluminescent detectors; hot particle; nuclear power plant;
D O I
10.1016/S1350-4487(01)00212-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Calibration and analysis of data obtained from a multicomponent thermoluminescent beta dosemeter are described. Measurements of directional equivalent dose rate of beta radiation and effective beta energy were carried out in the working environment of a nuclear power plant (Vandellos II) by means of thermoluminescent detectors. The effective beta energy ranges most frequently between 150 and 500 keV. The last version of the VARSKIN MOD 2 code has been used to calculate the directional dose equivalent rate (H)over dot ' (0.07, 0) and the personal dose equivalent rate (H)over dot(p)(10) corresponding to the hot particles found. A comparison between the calculated and the experimental values is presented. (C) 2001 Elsevier Science Ltd. All rights reserved.