A multi-harmonic RF system using a MA cavity

被引:10
作者
Ohmori, C
Kanazawa, M
Noda, K
Kawashima, M
Misu, T
Mori, Y
Sugiura, A
Takagi, A
Uesugi, T
机构
[1] KEK, Tsukuba, Ibaraki 3050801, Japan
[2] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[3] Accelerator Engn Corp, Inage Ku, Chiba 26300443, Japan
关键词
accelerator; RF system; multi-harmonic; space-charge;
D O I
10.1016/j.nima.2005.03.163
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A magnetic alloy (MA)-loaded cavity has been installed in Heavy Ion Medical Accelerator in Chiba (HIMAC). A beam study with a new Direct Digital Synthesis (DDS) system has been performed. The DDS system can generate multi-harmonic RF that includes up to 3 different RF frequencies. The multi-harmonic RF is amplified by a solid state and final amplifiers. These harmonic frequencies are in the band width of the MA RF system. Beam acceleration was performed by the system, and the acceleration efficiency was improved by both dual and triple harmonic RF. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:249 / 258
页数:10
相关论文
共 14 条
[1]   A 2ND HARMONIC (6-16 MHZ) RF SYSTEM WITH FEEDBACK-REDUCED GAP IMPEDANCE FOR ACCELERATING FLAT-TOPPED BUNCHES IN THE CERN PS BOOSTER [J].
BAILLOD, JM ;
MAGNANI, L ;
NASSIBIAN, G ;
PEDERSEN, F ;
WEISSFLOG, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (04) :3499-3501
[2]  
BLASKIEWEZ M, 1995, P PAC95, V95, P383
[3]   HIMAC RF system with a digital synthesizer [J].
Kanazawa, M ;
Sato, K ;
Itano, A ;
Sudou, M ;
Noda, K ;
Takada, E ;
Kumada, M ;
Yamazaki, C ;
Yamagishi, T ;
Morii, Y ;
Toyoda, E ;
Tsuzuki, N ;
Yagi, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (2-3) :205-214
[4]   INJECTION DYNAMICS AND MULTITURN CHARGE-EXCHANGE INJECTION INTO THE FAST CYCLING SYNCHROTRON FOR THE SNS [J].
KEMPSON, VC ;
PLANNER, CW ;
PUGH, VT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) :3085-3087
[5]  
KOSEIELNIAK S, 1996, P EPAC95
[6]  
MORI Y, 1998, P 6 EUR PART ACC C E, V98, P299
[7]  
Muramatsu R., 1999, Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366), P798, DOI 10.1109/PAC.1999.795359
[8]  
NISHIUCH H, 2004, P 1 ANN M PART ACC S, P507
[9]   Beam diagnostics using a chopped beam [J].
Ohmori, C ;
Kanazawa, M ;
Takagi, A ;
Noda, K ;
Uesugi, T ;
Shirakabe, Y ;
Sugiura, A ;
Mori, Y ;
Muto, M ;
Chou, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 526 (03) :215-221
[10]  
OHMORI C, 1999, P 1997 PART ACC C PA, V97, P413