A contemporary review of stereotactic radiotherapy: Inherent dosimetric complexities and the potential for detriment

被引:55
作者
Taylor, Michael L. [1 ,2 ,3 ]
Kron, Tomas [1 ,2 ]
Franich, Rick D. [1 ]
机构
[1] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3000, Australia
[2] Peter MacCallum Canc Ctr, Melbourne, Vic, Australia
[3] Alfred Hosp, William Buckland Radiotherapy Ctr, Prahran, Vic 3181, Australia
关键词
BODY RADIATION-THERAPY; POLYMER GEL DOSIMETRY; CELL LUNG-CANCER; MONTE-CARLO-SIMULATION; INTENSITY-MODULATED RADIOTHERAPY; GAMMA-KNIFE RADIOSURGERY; DOSE-RATE DEPENDENCE; SMALL PHOTON FIELDS; HIGH-ENERGY PHOTON; CEREBRAL ARTERIOVENOUS-MALFORMATIONS;
D O I
10.3109/0284186X.2010.551665
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective. The advantages of highly localised, conformal treatments achievable with stereotactic radiotherapy (SRT) are increasingly being extended to extracranial sites as stereotactic body radiotherapy with advancements in imaging and beam collimation. One of the challenges in stereotactic treatment lies in the significant complexities associated with small field dosimetry and dose calculation. This review provides a comprehensive overview of the complexities associated with stereotactic radiotherapy and the potential for detriment. Methods. This study is based on a comprehensive review of literature accessible via PubMed and other sources, covering stereotactic radiotherapy, small-field dosimetry and dose calculation. Findings. Several key issues were identified in the literature. They pertain to dose prescription, dose measurement and dose calculation within and beyond the treatment field. Field-edge regions and penumbrae occupy a significant portion of the total field size. Spectral and dosimetric characteristics are difficult to determine and are compounded by effects of tissue inhomogeneity. Measurement of small-fields is made difficult by detector volume averaging and energy response. Available dosimeters are compared, and emphasis is given to gel dosimetry which offers the greatest potential for three-dimensional small-field dosimetry. The limitations of treatment planning system algorithms as applied to small-fields (particularly in the presence of heterogeneities) is explained, and a review of Monte Carlo dose calculation is provided, including simplified treatment planning implementations. Not incorporated into treatment planning, there is evidence that far from the primary field, doses to patients (and corresponding risks of radiocarcinogenesis) from leakage/scatter in SRT are similar to large fields. Conclusions. Improved knowledge of dosimetric issues is essential to the accurate measurement and calculation of dose as well as the interpretation and assessment of planned and delivered treatments. This review highlights such issues and the potential benefit that may be gained from Monte Carlo dose calculation and verification via three-dimensional dosimetric methods (such as gel dosimetry) being introduced into routine clinical practice.
引用
收藏
页码:483 / 508
页数:26
相关论文
共 258 条
[1]   Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume [J].
Admiraal, Marjan A. ;
Schuring, Danny ;
Hurkmans, Coen W. .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) :55-60
[2]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[3]   Dose calculations for external photon beams in radiotherapy [J].
Ahnesjö, A ;
Aspradakis, MM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :R99-R155
[4]  
Alecu R, 1999, Med Dosim, V24, P5, DOI 10.1016/S0958-3947(98)00045-4
[5]   Present Status of IAEA/AAPM Recommendations on Small and Composite Field Dosimetry [J].
Alfonso, R. ;
Andreo, P. ;
Noy, R. Capote ;
Huq, M. ;
Izewska, J. ;
Johansson, J. ;
Kilby, W. ;
Mackie, T. ;
Meghzifene, A. ;
Palmans, H. ;
Rosser, K. ;
Seuntjens, J. ;
Ullrich, W. .
MEDICAL PHYSICS, 2010, 37 (06) :3096-+
[6]   STOPPING POWER DATA FOR HIGH-ENERGY PHOTON BEAMS [J].
ANDREO, P ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (08) :839-858
[7]  
[Anonymous], 1993, J ICRU
[8]  
[Anonymous], 13 WORLD C LUNG CANC
[9]   Clinical outcome of hypofractionated conventional conformation radiotherapy for patients with single and no more than three metastatic brain tumors, with noninvasive fixation of the skull without whole brain irradiation [J].
Aoki, M ;
Abe, Y ;
Hatayama, Y ;
Kondo, H ;
Basaki, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :414-418
[10]   Monte Carlo study of a Cyberknife stereotactic radiosurgery system [J].
Araki, Fujio .
MEDICAL PHYSICS, 2006, 33 (08) :2955-2963