Targeted multidimensional gas chromatography using microswitching and cryogenic modulation

被引:32
作者
Marriott, P [1 ]
Dunn, M [1 ]
Shellie, R [1 ]
Morrison, P [1 ]
机构
[1] RMIT Univ, Dept Appl Chem, Australian Ctr Res Separat Sci, Melbourne, Vic 3001, Australia
关键词
D O I
10.1021/ac034492k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method is described that allows fast target analysis in multidimensional gas chromatography by using a microswitching valve between two GC columns, with cryogenic trapping and rapid re-injection of trapped solutes in the second dimension. The essence of the procedure is that heart-cut fractions from the first column (D-1) can be selectively transferred to column 2 (D-2), where a moveable cryogenic trap first focuses the transferred solute(s) at the head of the second column and then permits their facile rapid analysis on D-2. Since D-2 is a short narrow-bore column, which exhibits very fast analysis (on the order of a few seconds elution), peak responses (heights) are significantly enhanced (by up to 40-fold). Additionally, by using a D-2 phase of a selectivity different from that used for ID, it is possible to also separate components that are not resolved on the first column and to increase the resolution for other compounds. The heart-cut valve isolates the section(s) of solutes of interest from the first column separation, and this provides a considerable simplification to the chromatogram-in addition to the separation and sensitivity advantages. By using this method, multidimensional gas chromatography with multiple heart-cuts can be completed within the same time as the primary column separation. Since the described method permits non-heart-cut fractions to be transferred to a monitor detector, normal detection of these fractions is still permitted. By modulation of the cryotrap, it is also possible to achieve comprehensive two-dimensional gas chromatography for the heart-cut fractions; however, only those compounds passed to the second, separation column, which passes through the cryotrap, will be subjected to GC x GC analysis. The technique and the various modes of operation are described in this paper.
引用
收藏
页码:5532 / 5538
页数:7
相关论文
共 35 条
[1]   Simultaneous pulsed flame photometric and mass spectrometric detection for enhanced pesticide analysis capabilities [J].
Amirav, A ;
Jing, HW .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :133-150
[2]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[3]  
2-V
[4]  
Bertsch W, 2000, HRC-J HIGH RES CHROM, V23, P167
[5]   Cyclodextrin derivatives as chiral selectors for direct gas chromatographic separation of enantiomers in the essential oil, aroma and flavour fields [J].
Bicchi, C ;
D'Amato, A ;
Rubiolo, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :99-121
[6]   USE OF 2-DIMENSIONAL GAS-CHROMATOGRAPHY IN THE DIRECT ENANTIOMER SEPARATION OF CHIRAL ESSENTIAL OIL COMPONENTS [J].
BICCHI, C ;
PISCIOTTA, A .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (02) :341-348
[7]   Unravelling the composition of very complex samples by comprehensive gas chromatography coupled to time-of-flight mass spectrometry -: Cigarette smoke [J].
Dallüge, J ;
van Stee, LLP ;
Xu, XB ;
Williams, J ;
Beens, J ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :169-184
[8]  
DAVID F, 1987, CAPILLARY GAS CHROMA, P387
[9]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323
[10]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&