Fast, Sensitive Bioanalytical Method Development and Validation for the Determination of Escitalopram in Human Plasma by Liquid Chromatography- Electrospray, Tandem Mass Spectrometry

被引:0
作者
Beludari, Mohammed I. [1 ]
Lingareddygari, Siva S. R. [1 ]
Dara, China B. [1 ]
Munna, Sreenivasulu [1 ]
Challa, Madhusudhana C. [1 ]
Karnam, Vanitha P. [2 ]
机构
[1] Santhiram Coll Pharm, Dept Pharmaceut Anal, Nandyal, AP, India
[2] SSJ Coll Pharm, Dept Pharmaceut Anal, Hyderabad, Telangana, India
来源
LATIN AMERICAN JOURNAL OF PHARMACY | 2020年 / 39卷 / 03期
关键词
ammonium formate; escitalopram; human plasma; imipramine; methyl-tert-butyl ether; SEROTONIN REUPTAKE INHIBITORS; CITALOPRAM HYDROBROMIDE; SPECTROPHOTOMETRIC METHODS; ENANTIOSELECTIVE ANALYSIS; LC-MS/MS; METABOLITES; ANTIDEPRESSANTS; ULTRAVIOLET;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A simple, reproducible and fast (1.5 min chromatogram) bioanalytical method of liquid chromatography and tandem with mass detector (LC/MS-MS) was developed and validated to determine escitalopram (ESP) in human plasma using liquid-liquid extraction technique. Imipramine (IMP) was used as internal standard (IS) and K2 EDTA was used as anti-coagulant. Analytes were extracted by methyl-tertbutyl ether (MTBE) and subsequent separation on a Luna 3 mu m C18, 100 x 4.60 mm column using acetonitrile:10 mM ammonium formate pH 4.5 (90:10 v/v) as mobile phase at a flow rate of 1 mL/min and 30 +/- 3o C column oven temperature. Analytes were monitored with electrospray ionization in positive multiple reaction mode (MRM) for both ESP and IMP using quadrupole MS/MS spectrometer. ESP and IMP were detected with proton adducts at m/z 324.20 -> 110.13 for ESP and 280.8/86.0 for IMP. ESP and IMP were eluted at 0.655 and 0.745 min, respectively. The method was validated over a linear (r(2) = 0.9979) concentration range of 306.022 to 199205.354 pg/mL. The inter-day and intra-day precisions were found to be less than 15% and the accuracy was all within +/- 15% (at LLOQ +/- 20%). The developed LC-MS/MS method was fully validated for all the other parameters as per FDA guidelines like selectivity, matrix effect, recovery and stability as well. Due to the high degree of sensitivity, very less time consuming, easy extraction procedure and low requirement of sample volume, the method will be applicable for therapeutic drug monitoring.
引用
收藏
页码:532 / 540
页数:9
相关论文
共 50 条
[1]   Bioanalytical method development and validation of a liquid chromatography-tandem mass spectrometry method for determination of β-lapachone in human plasma [J].
Putnam, William C. ;
Kallem, Raja Reddy ;
Subramaniyan, Indhumathy ;
Beg, M. Shaalan ;
Edpuganti, Vindhya .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188
[2]   A Liquid Chromatography-Tandem Mass Spectrometry Bioanalytical Method Development and Validation for the Determination of Pacritinib in Plasma [J].
Kumar, Mulamraju Aruna ;
Bangaraiah, Pagala .
SEPARATION SCIENCE PLUS, 2024, 7 (12)
[3]   Development and validation of a sensitive liquid chromatography/tandem mass spectrometry method for the determination of exemestane in human plasma [J].
Ksycinska, Hanna ;
Bus-Kwasnik, Katarzyna ;
Szlagowska, Anna ;
Rudzki, Piotr J. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21) :1905-1910
[4]   A Very Sensitive Bioanalytical Method for the Estimation of Escitalopram in Rat Plasma Using Liquid Chromatography with Tandem Mass Spectrometry-Application to Animal Pharmacokinetic Study [J].
Rai, Amita ;
Shetty, Raghavendra ;
Prabhu, Harish ;
Theerthahalli, Aruna ;
Kumar, N. ;
Krishnadas, N. ;
Khan, A. H. .
INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 84 (02) :380-389
[5]   CHALLENGES IN BIOANALYTICAL METHOD DEVELOPMENT FOR SIMULTANEOUS DETERMINATION OF OLMESARTAN AND HYDROCHLOROTHIAZIDE IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY COUPLED TO TANDEM MASS SPECTROMETRY [J].
Kumar, Ajay ;
Verma, Priya Ranjan Prasad ;
Monif, Tausif ;
Khuroo, Arshad H. ;
Iyer, Sunil S. ;
Singh, Abhishek Kumar .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) :59-78
[6]   Development and Validation of an Ultra-Performance Liquid Chromatography/Electrospray Ionization-Tandem Mass Spectrometry Bioanalytical Method for Quantifying Clonazepam in Human Plasma [J].
Jann Favreto, Wagner Alex ;
Pugens Pinto, Ana Maria ;
Manfio, Joselia Larger ;
Hoss, Ivonete ;
Pristch, Mariely Camila ;
Bordignon, Solange Fatima .
JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (04) :745-750
[7]   Development and Validation of a Bioanalytical Method for Estimation of Prucalopride in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry [J].
Vemuluri, Padmabhushana Chary ;
Dodda, Sireesha ;
Polagani, Srinivasa Rao .
JOURNAL OF APPLIED SPECTROSCOPY, 2025, 92 (02) :388-392
[8]   Determination of Escitalopram in Human Plasma by High Performance Liquid Chromatography-Tandem Mass Spectrometry [J].
de Sousa, Carlos E. M. ;
Bonifacio, Felipe N. ;
Bedor, Danilo C. G. ;
Silva, Thayse M. ;
Ramos, Virna L. S. ;
de Souza Filho, Jose H. ;
Leal, Leila B. ;
Oliveira, Amanda T. C. ;
de Santana, Davi P. .
LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02) :310-314
[9]   Development and validation of a fast and sensitive bioanalytical method for the quantitative determination of glucocorticoids-Quantitative measurement of dexamethasone in rabbit ocular matrices by liquid chromatography tandem mass spectrometry [J].
Earla, Ravinder ;
Boddu, Sai H. S. ;
Cholkar, Kishore ;
Hariharan, Sudharshan ;
Jwala, Jwala ;
Mitra, Ashim K. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (04) :525-533
[10]   New Bioanalytical Method Development and Validation for Extraction of Mirabegron in Human Plasma by using Quechers Method and Liquid Chromatography-Tandem Mass Spectrometry [J].
Mahesh, M. ;
Devanna, N. .
ASIAN JOURNAL OF PHARMACEUTICS, 2025, 19 (02) :647-655