Fast, Sensitive Bioanalytical Method Development and Validation for the Determination of Escitalopram in Human Plasma by Liquid Chromatography- Electrospray, Tandem Mass Spectrometry

被引:0
|
作者
Beludari, Mohammed I. [1 ]
Lingareddygari, Siva S. R. [1 ]
Dara, China B. [1 ]
Munna, Sreenivasulu [1 ]
Challa, Madhusudhana C. [1 ]
Karnam, Vanitha P. [2 ]
机构
[1] Santhiram Coll Pharm, Dept Pharmaceut Anal, Nandyal, AP, India
[2] SSJ Coll Pharm, Dept Pharmaceut Anal, Hyderabad, Telangana, India
来源
LATIN AMERICAN JOURNAL OF PHARMACY | 2020年 / 39卷 / 03期
关键词
ammonium formate; escitalopram; human plasma; imipramine; methyl-tert-butyl ether; SEROTONIN REUPTAKE INHIBITORS; CITALOPRAM HYDROBROMIDE; SPECTROPHOTOMETRIC METHODS; ENANTIOSELECTIVE ANALYSIS; LC-MS/MS; METABOLITES; ANTIDEPRESSANTS; ULTRAVIOLET;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A simple, reproducible and fast (1.5 min chromatogram) bioanalytical method of liquid chromatography and tandem with mass detector (LC/MS-MS) was developed and validated to determine escitalopram (ESP) in human plasma using liquid-liquid extraction technique. Imipramine (IMP) was used as internal standard (IS) and K2 EDTA was used as anti-coagulant. Analytes were extracted by methyl-tertbutyl ether (MTBE) and subsequent separation on a Luna 3 mu m C18, 100 x 4.60 mm column using acetonitrile:10 mM ammonium formate pH 4.5 (90:10 v/v) as mobile phase at a flow rate of 1 mL/min and 30 +/- 3o C column oven temperature. Analytes were monitored with electrospray ionization in positive multiple reaction mode (MRM) for both ESP and IMP using quadrupole MS/MS spectrometer. ESP and IMP were detected with proton adducts at m/z 324.20 -> 110.13 for ESP and 280.8/86.0 for IMP. ESP and IMP were eluted at 0.655 and 0.745 min, respectively. The method was validated over a linear (r(2) = 0.9979) concentration range of 306.022 to 199205.354 pg/mL. The inter-day and intra-day precisions were found to be less than 15% and the accuracy was all within +/- 15% (at LLOQ +/- 20%). The developed LC-MS/MS method was fully validated for all the other parameters as per FDA guidelines like selectivity, matrix effect, recovery and stability as well. Due to the high degree of sensitivity, very less time consuming, easy extraction procedure and low requirement of sample volume, the method will be applicable for therapeutic drug monitoring.
引用
收藏
页码:532 / 540
页数:9
相关论文
共 50 条
  • [1] Bioanalytical method development and validation of a liquid chromatography-tandem mass spectrometry method for determination of β-lapachone in human plasma
    Putnam, William C.
    Kallem, Raja Reddy
    Subramaniyan, Indhumathy
    Beg, M. Shaalan
    Edpuganti, Vindhya
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188
  • [2] Development and validation of a sensitive liquid chromatography/tandem mass spectrometry method for the determination of exemestane in human plasma
    Ksycinska, Hanna
    Bus-Kwasnik, Katarzyna
    Szlagowska, Anna
    Rudzki, Piotr J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (21): : 1905 - 1910
  • [3] A Liquid Chromatography-Tandem Mass Spectrometry Bioanalytical Method Development and Validation for the Determination of Pacritinib in Plasma
    Kumar, Mulamraju Aruna
    Bangaraiah, Pagala
    SEPARATION SCIENCE PLUS, 2024, 7 (12):
  • [4] Development and validation of a sensitive liquid chromatography/electrospray tandem mass spectrometry assay for the quantification of olanzapine in human plasma
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikumar
    Yeffamilli, Anjaneyulu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 935 - 942
  • [5] Development and Validation of an Ultra-Performance Liquid Chromatography/Electrospray Ionization-Tandem Mass Spectrometry Bioanalytical Method for Quantifying Clonazepam in Human Plasma
    Jann Favreto, Wagner Alex
    Pugens Pinto, Ana Maria
    Manfio, Joselia Larger
    Hoss, Ivonete
    Pristch, Mariely Camila
    Bordignon, Solange Fatima
    JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (04) : 745 - 750
  • [6] Bioanalytical Method Development and Validation of Selinexor in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Yaswanth, Murthaeti
    Sreekanth, M.
    Valli, Syed Sadaq
    Narayana, D. Venkata
    Sreedhar, V
    Venkataramana, Kanuma
    Pravallika, K. E.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 (04): : 41 - 53
  • [7] A simple and fast method for the inspection of preservatives in cheeses and cream by liquid chromatography- electrospray tandem mass spectrometry
    Molognoni, Luciano
    de Sa Ploencio, Leandro Antunes
    Valese, Andressa Camargo
    Lindner, Juliano De Dea
    Daguer, Heitor
    TALANTA, 2016, 147 : 370 - 382
  • [8] Development and validation of a liquid chromatography/tandem mass spectrometry method for the determination of DMXAA in human and mouse plasma
    Zhang, Xiaosong
    Zhao, Ming
    Rudek, Michelle A.
    He, Ping
    Vogelstein, Bert
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 217 - 222
  • [9] Determination of gatifloxacin in human plasma by liquid chromatography/electrospray tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 915 - 919
  • [10] Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma
    Puangpetch, Apichaya
    Limrungsikul, Anchalee
    Prommas, Santirhat
    Rukthong, Pattarawit
    Sukasem, Chonlaphat
    CLINICAL MASS SPECTROMETRY, 2020, 15 : 6 - 12