Ceraflex versus Amplatzer occluder for secundum atrial septal defect closure Multicenter clinical experience

被引:0
作者
Astarcioglu, M. A. [1 ]
Kalcik, M. [2 ]
Sen, T. [1 ]
Aykan, A. C. [3 ]
Gokdeniz, T. [4 ]
Gursoy, O. M. [2 ]
Karakoyun, S. [4 ]
Kulahcioglu, S. [2 ]
Gunduz, S. [2 ]
Kilit, C. [5 ]
Oylumlu, M. [5 ]
Amasyali, B. [5 ]
机构
[1] Evliya Celebi Training & Res Hosp, Dept Cardiol, Kutahya, Turkey
[2] Kosuyolu Kartal Heart Training & Res Hosp, Dept Cardiol, Istanbul, Turkey
[3] Ahi Evran Training & Res Hosp, Dept Cardiol, Trabzon, Turkey
[4] Kars Kafkas Med Fac, Dept Cardiol, Kars, Turkey
[5] Dumlupinar Univ, Dept Cardiol, Kutahya, Turkey
关键词
Atrial septal defect; Interventional cardiology; Occlusion device; Amplatzer; Ceraflex; TRANSCATHETER CLOSURE; COMPLICATIONS; INTERMEDIATE; ADULTS; DEVICE;
D O I
10.1007/s00059-014-4192-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Ceraflex atrial septal defect occluder is an alternative device to the Amplatzer septal occluder with some structural innovations including flexible connection, increased flexibility, and minimized amount of implant material. We evaluated the efficiency and safety of the Ceraflex septal occluder device in percutaneous closure of secundum atrial septal defects. This was a prospective, nonrandomized, multicenter study of patients undergoing transcatheter closure for an atrial septal defect with the Ceraflex and the Amplatzer septal occluder devices. A clinical evaluation and follow-up transthoracic echocardiography were performed at 1, 6, and 12 months. Between 2010 and 2014, 125 patients underwent atrial septal defect closure with the Ceraflex septal occluder (n = 58) and the Amplatzer septal occluder (n = 67) under transesophageal echocardiography guidance. Patient characteristics, the stretched size of the defect, device size, and fluoroscopy time were similar between the groups. The immediate and follow-up complete occlusion rates for both groups were 100%. There was no device embolization, procedure-related stroke, or pericardial effusion. The Ceraflex septal occluder is a safe and efficient device for closure of secundum atrial septal defects with no procedural complications. The Ceraflex has similar outcomes when compared with the Amplatzer septal occluder device. The advantage of the Ceraflex septal occluder device is that it can be deployed without the tension of the delivery catheter.
引用
收藏
页码:146 / 150
页数:5
相关论文
共 18 条
[1]   Erosion of amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk [J].
Amin, Z ;
Hijazi, ZM ;
Bass, JL ;
Cheatham, JP ;
Hellenbrand, WE ;
Kleinman, CS .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) :496-502
[2]   Transcatheter closure as standard treatment for most interatrial defects:: experience in 200 patients treated with the Amplatzer™ Septal Occluder [J].
Berger, F ;
Ewert, P ;
Björnstad, PG ;
Dähnert, I ;
Krings, G ;
Brilla-Austgenat, I ;
Vogel, M ;
Lange, PE .
CARDIOLOGY IN THE YOUNG, 1999, 9 (05) :468-473
[3]  
Chan KC, 1999, HEART, V82, P100
[4]   Early and late complications associated with transcatheter occlusion of secundum atrial septal defect [J].
Chessa, M ;
Carminati, M ;
Butera, G ;
Bini, RM ;
Drago, M ;
Rosti, L ;
Giamberti, A ;
Pomè, G ;
Bossone, E ;
Frigiola, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) :1061-1065
[5]   Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults - Results of a multicenter nonrandomized trial [J].
Du, ZD ;
Hijazi, ZM ;
Kleinman, CS ;
Silverman, NH ;
Larnitz, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (11) :1836-1844
[6]  
Ilkay E, 2010, TURK KARDIYOL DERN A, V38, P189
[7]   SECUNDUM ATRIAL SEPTAL-DEFECT - NONOPERATIVE CLOSURE DURING CARDIAC-CATHETERIZATION [J].
KING, TD ;
THOMPSON, SL ;
STEINER, C ;
MILLS, NL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (23) :2506-2509
[8]   Embolization and retrieval of the amplatzer septal occluder [J].
Levi, DS ;
Moore, JW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (04) :543-547
[9]   Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders [J].
Masura, J ;
Gavora, P ;
Podnar, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (04) :505-507
[10]  
Patel Angira, 2007, J Interv Cardiol, V20, P82, DOI 10.1111/j.1540-8183.2007.00216.x