Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters

被引:74
作者
Wang, J [1 ]
Lu, HB [1 ]
Li, TF [1 ]
Liang, ZR [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
来源
MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3 | 2005年 / 5747卷
关键词
low-dose CT; sinogram noise reduction; statistics-based nonlinear filters; streak artifacts; KL--PWLS;
D O I
10.1117/12.595662
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Low-dose CT (computed tomography) sinogram data have been shown to be signal-dependent with an analytical relationship between the sample mean and sample variance. Spatially-invariant low-pass linear filters, such as the Butterworth and Harming filters, could not adequately handle the data noise and statistics-based nonlinear filters may be an alternative choice. in addition to other choices of minimizing cost functions on the noisy data. Anisotropic diffusion filter and nonlinear Gaussian filters chain (NLGC) are two well-known classes of nonlinear filters based on local statistics for the purpose of edge-preserving noise reduction. These two filters can utilize the noise properties of the low-dose CT sinogram for adaptive noise reduction. but can not incorporate signal correlative information for an optimal regularized solution. Our previously-developed Karhunen-Loeve (KL) domain PWLS (penalized Weighted least square) minimization considers the signal correlation via the KL strategy and seeks the PWLS cost function minimization for an optimal regularized solution for each KL component, i.e., adaptive to the KL components. This work compared the nonlinear filters with the KL-PWLS framework for low-dose CT application. Furthermore, we investigated the nonlinear filters for post KL-PWLS noise treatment in the sinogram space, where the filters 'were applied after ramp operation on the KL-PWLS treated sinogram data prior to backprojection operation (for image reconstruction). By both computer simulation and experimental low-dose CT data. the nonlinear filters could not outperform the KL-PWLS framework. The gain of post KL-PWLS edge-preserving noise filtering in the sinogram space is not significant, even the noise has been modulated by the ramp operation.
引用
收藏
页码:2058 / 2066
页数:9
相关论文
共 17 条
[1]  
[Anonymous], 1995, P MUSTERERKENNUNG 19
[2]  
Chu CK, 1998, J AM STAT ASSOC, V93, P526, DOI 10.2307/2670100
[3]  
DEMIRKAYA O, 2001, SPIE MED IMAGING, V4322, P97
[4]   Efficient and accurate likelihood for iterative image reconstruction in x-ray computed tomography [J].
Elbakri, LA ;
Fessler, JA .
MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 :1839-1850
[5]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[6]   Nonlinear sinogram smoothing for low-dose X-ray CT [J].
Li, TF ;
Li, X ;
Wang, J ;
Wen, JH ;
Lu, HB ;
Hsieh, J ;
Liang, ZR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2505-2513
[7]  
LI TF, 2003, IEEE NSS MIC
[8]  
LI TF, 2004, SPIE MED IMAGING, V5730, P2058
[9]   Local scale controlled anisotropic diffusion with local noise estimate for image smoothing and edge detection [J].
Liang, P ;
Wang, YF .
SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, :193-200
[10]   National Conference on Dose Reduction in CT, with an emphasis on pediatric patients [J].
Linton, OW ;
Mettler, FA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) :321-329