Transcritical carbon dioxide small commercial cooling applications analysis

被引:19
作者
Cecchinato, Luca [1 ]
Corradi, Marco [1 ]
机构
[1] Univ Padua, Dipartimento Fis Tecn, I-35131 Padua, Italy
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2011年 / 34卷 / 01期
关键词
Capillary; Carbon dioxide; Commercial application; High pressure; Optimisation; Transcritical cycle;
D O I
10.1016/j.ijrefrig.2010.09.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a project to develop an R744 commercial single door bottle cooler that is cost competitive and matches the performance of typical cost optimised R404A and R134a systems. Compressors with different displacement and efficiency values are evaluated for refrigerating systems with fin and tube and steel wire-on-tube gas coolers. Capillary tubes are tested. A methodology to properly sizing them and to optimize the combination of capillary tube and refrigerant charge is developed. The problem of optimal cycle high pressure is addressed and Liao's approximated solution questioned. Tests demonstrate that the CO2 energy consumption systems are higher than traditional ones especially at ambient temperatures above 25 degrees C. Carbon dioxide appears to be a feasible option for stand-alone refrigerating equipment in terms of total equivalent warming impact (TEWI) compared to HFC refrigerants with actual single stage R744 compressor technology, only if the refrigeration units operate at medium-low gas cooler inlet temperature. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:50 / 62
页数:13
相关论文
共 30 条
[1]  
*ANSI AHAM, 1988, HRF11988 ANSIAHAM
[2]   Optimisation of the throttling system in a CO2 refrigerating machine [J].
Casson, V ;
Cecchinato, L ;
Corradi, M ;
Fornasieri, E ;
Girotto, S ;
Minetto, S ;
Zamboni, L ;
Zilio, C .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (08) :926-935
[3]  
CAVALLINI A, 2001, P 6 C IB AIR AC REFR, P761
[4]   Carbon dioxide as refrigerant for tap water heat pumps: A comparison with the traditional solution [J].
Cecchinato, L ;
Corradi, M ;
Fornasieri, E ;
Zamboni, L .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1250-1258
[5]  
Cecchinato L., 2007, 22 IIR INT C REFR BE
[6]  
CECCHINATO L, 2006, 7 IIR G LOR C NAT WO
[7]   A critical approach to the determination of optimal heat rejection pressure in transcritical systems [J].
Cecchinato, Luca ;
Corradi, Marco ;
Minetto, Silvia .
APPLIED THERMAL ENGINEERING, 2010, 30 (13) :1812-1823
[8]   Thermodynamic analysis of different two-stage transcritical carbon dioxide cycles [J].
Cecchinato, Luca ;
Chiarello, Manuel ;
Corradi, Marco ;
Fornasieri, Ezio ;
Minetto, Silvia ;
Stringari, Paolo ;
Zilio, Claudio .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05) :1058-1067
[9]  
*CECED, 2000, OP COD APPL TEST REF
[10]  
*COC COL CO, COC COL OUR ENV VAL