ECG sonification to support the diagnosis and monitoring of myocardial infarction

被引:9
|
作者
Aldana Blanco, Andrea Lorena [1 ]
Grautoff, Steffen [2 ]
Hermann, Thomas [1 ]
机构
[1] Bielefeld Univ, CITEC, Inspirat 1, D-33619 Bielefeld, Germany
[2] Klinikum Herford, Schwarzenmoorstr 70, D-32049 Herford, Germany
关键词
Electrocardiogram; Sonification; Process monitoring; Myocardial infarction; ST-SEGMENT;
D O I
10.1007/s12193-020-00319-x
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper presents the design and evaluation of four sonification methods to support monitoring and diagnosis in Electrocardiography (ECG). In particular we focus on an ECG abnormality called ST-elevation which is an important indicator of a myocardial infarction. Since myocardial infarction represents a life-threatening condition it is of essential value to detect an ST-elevation as early as possible. As part of the evaluated sound designs, we propose two novel sonifications: (i) Polarity sonification, a continuous parameter-mapping sonification using a formant synthesizer and (ii) Stethoscope sonification, a combination of the ECG signal and a stethoscope recording. The other two designs, (iii) the water ambience sonification and the (iv) morph sonification, were presented in our previous work about ECG sonification (Aldana Blanco AL, Steffen G, Thomas H (2016) In: Proceedings of Interactive Sonification Workshop (ISon). Bielefeld, Germany). The study evaluates three components across the proposed sonifications (1) detection performance, meaning if participants are able to detect a transition from healthy to unhealthy states, (2) classification accuracy, that evaluates if participants can accurately classify the severity of the pathology, and (3) aesthetics and usability (pleasantness, informativeness and long-term listening). The study results show that the polarity design had the highest accuracy rates in the detection task whereas the stethoscope sonification obtained the better score in the classification assignment. Concerning aesthetics, the water ambience sonification was regarded as the most pleasant. Furthermore, we found a significant difference between sound/music experts and non-experts in terms of the error rates obtained in the detection task using the morph sonification and also in the classification task using the stethoscope sonification. Overall, the group of experts obtained lower error rates than the group of non-experts, which means that further training could improve accuracy rates and, particularly for designs that rely mainly on pitch variations, additional training is needed in the non-experts group.
引用
收藏
页码:207 / 218
页数:12
相关论文
共 50 条
  • [41] Association between admission ECG changes and long-term mortality in patients with an incidental myocardial infarction: Results from the KORA myocardial infarction registry
    Schmitz, Timo
    Wein, Bastian
    Methe, Heiko
    Linseisen, Jakob
    Heier, Margit
    Peters, Annette
    Meisinger, Christa
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2022, 100 : 69 - 76
  • [42] ECG scores for a triage of patients with acute myocardial infarction transported by the emergency medical system
    Zalenski, RJ
    Grzybowski, M
    Ross, MA
    Blaustein, N
    Bock, B
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 : 245 - 249
  • [43] Monitoring after acute myocardial infarction
    Muth, K.
    Senges, J.
    Zeymer, U.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2007, 132 (39) : 2021 - 2023
  • [44] The development of a myocardial infarction monitoring system
    Lou, ZG
    Luo, W
    Li, J
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 450 - 451
  • [45] False positive ECG reports of anterior myocardial infarction in women
    Colaco, R
    Reay, P
    Beckett, C
    Aitchison, TC
    Macfarlane, PW
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 : 239 - 244
  • [46] Body surface ECG potential maps in acute myocardial infarction
    McMechan, SR
    MacKenzie, G
    Allen, J
    Wright, GT
    Dempsey, GJ
    Crawley, M
    Anderson, J
    Adgey, AAJ
    JOURNAL OF ELECTROCARDIOLOGY, 1995, 28 : 184 - 190
  • [47] Dissimilarity Factor Based Classification of Inferior Myocardial Infarction ECG
    Gupta, Rajarshi
    Kundu, Palash
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONTROL, MEASUREMENT AND INSTRUMENTATION (CMI), 2016, : 229 - 233
  • [48] Standard 12-lead ECG versus special chest leads in the diagnosis of right ventricular myocardial infarction
    Madias, JE
    Mahjoub, M
    Wijetilaka, R
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1997, 15 (01) : 89 - 90
  • [49] Performance Enhancement for Detection of Myocardial Infarction from Multilead ECG
    Kasar, Smita L.
    Joshi, Madhuri S.
    Mishra, Abhilasha
    Mahajan, S. B.
    Sanjeevikumar, P.
    ARTIFICIAL INTELLIGENCE AND EVOLUTIONARY COMPUTATIONS IN ENGINEERING SYSTEMS, ICAIECES 2017, 2018, 668 : 697 - 705
  • [50] Influence of Age on the Diagnosis of Myocardial Infarction
    Lowry, Matthew T. H.
    Doudesis, Dimitrios
    Wereski, Ryan
    Kimenai, Dorien M.
    Tuck, Christopher
    Ferry, Amy, V
    Bularga, Anda
    Taggart, Caelan
    Lee, Kuan K.
    Chapman, Andrew R.
    Shah, Anoop S., V
    Newby, David E.
    Mills, Nicholas L.
    Anand, Atul
    CIRCULATION, 2022, 146 (15) : 1135 - 1148