First-in-Human ExperienceWith Integration of a Hydrocephalus Shunt Device Within a Customized Cranial Implant

被引:24
作者
Gordon, Chad R. [1 ,2 ]
Wolff, Amir [1 ,2 ]
Santiago, Gabriel F. [1 ,2 ]
Liebman, Kenneth [3 ,5 ]
Veznedaroglu, Erol [3 ,5 ]
Vrionis, Frank D. [4 ]
Huang, Judy [2 ]
Brem, Henry [2 ]
Luciano, Mark [2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Div Neuroplast & Reconstruct Surg,Surg, Johns Hopkins Hosp,Dept Plast & Reconstruct Surg, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Dept Neurosurg, Johns Hopkins Hosp, Baltimore, MD 21205 USA
[3] Drexel Coll Med, Dept Neurosurg, Philadelphia, PA USA
[4] Boca Raton Reg Hosp, Marcus Neurosci Inst, Boca Raton, FL USA
[5] Drexel Univ, Coll Med, Dept Neurosurg, Global Neurosci Inst, Philadelphia, PA 19104 USA
关键词
Hydrocephalus shunt; Cranioplasty; Cranial implant; Shunt complication; Implant extrusion; Scalp wound; Ventriculoperitoneal shunt;
D O I
10.1093/ons/opz003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Implantable shunt devices are critical and life saving for hydrocephalus patients. However, these devices are fraught with high complication rates including scalp dehiscence, exposure, and extrusion. In fact, high shunt valve profiles are correlated with increased complications compared to those with lower profiles. As such, we sought a new method for integrating shunt valves for those challenging patients presenting with scalp-related complications. OBJECTIVE: To safely implant and integrate a hydrocephalus shunt valve device within a customized cranial implant, in an effort to limit its high-profile nature as a main contributor to shunt failure and scalp breakdown, and at the same time, improve patient satisfaction by preventing contour deformity. METHODS: A 64-yr-old male presented with an extruding hydrocephalus shunt valve and chronic, open scalp wound. The shunt valve was removed and temporary shunt externalization was performed. He received 2 wk of culture-directed antibiotics. Next, a contralateral craniectomy was performed allowing a new shunt valve system to be implanted within a low-profile, customized cranial implant. All efforts were made, at the patient's request, to decrease the high-profile nature of the shunt valve contributing to his most recent complication. RESULTS: First-in-human implantation was performed without complication. Postoperative shunt identification and programming was uncomplicated. The high-profile nature of the shunt valve was decreased by 87%. At 10 mo, the patient has experienced no complications and is extremely satisfied with his appearance. CONCLUSION: This first-in-human experience suggests that a high-profile hydrocephalus shunt device may be safely integrated within a customized cranial implant.
引用
收藏
页码:608 / 615
页数:8
相关论文
共 14 条
  • [1] A LONG-TERM COMPLICATION OF BURYING A SHUNT VALVE IN THE SKULL
    AMMAR, A
    NASSER, M
    [J]. NEUROSURGICAL REVIEW, 1995, 18 (01) : 65 - 67
  • [2] Comparative Cost Analysis of Single and Mutli-Stage Temporal Deformity Correction Following Neurosurgical Procedures
    Asemota, Anthony
    Santiago, Gabriel F.
    Zhong, Susan
    Gordon, Chad R.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (01) : 130 - 138
  • [3] "Reverse J Shaped" Skin Flap and Cranial Bone Groove for Shunt Hardware: A New Technique for Patients with Fragile Skin
    Cakir, Murteza
    [J]. TURKISH NEUROSURGERY, 2019, 29 (02) : 312 - 315
  • [4] Cost-consequence analysis of antibiotic-impregnated shunts and external ventricular drains in hydrocephalus
    Edwards, Natalie C.
    Engelhart, Luella
    Casamento, Eva M. H.
    McGirt, Matthew J.
    [J]. JOURNAL OF NEUROSURGERY, 2015, 122 (01) : 139 - 147
  • [5] First In-Human Experience With Complete Integration of Neuromodulation Device Within a Customized Cranial Implant
    Gordon, Chad R.
    Santiago, Gabriel F.
    Huang, Judy
    Bergey, Gregory K.
    Liu, Shuya
    Armand, Mehran
    Brem, Henry
    Anderson, William S.
    [J]. OPERATIVE NEUROSURGERY, 2018, 15 (01) : 39 - 45
  • [6] Joo Jae Doo, 2017, Arch Craniofac Surg, V18, P186, DOI 10.7181/acfs.2017.18.3.186
  • [7] TIME-RELATED PATTERNS OF VENTRICULAR SHUNT FAILURE
    KAST, J
    DUONG, D
    NOWZARI, F
    CHADDUCK, WM
    SCHIFF, SJ
    [J]. CHILDS NERVOUS SYSTEM, 1994, 10 (08) : 524 - 528
  • [8] Khan Farid, 2015, Surg Neurol Int, V6, P25, DOI 10.4103/2152-7806.151388
  • [9] Forty years of shunt surgery at Rigshospitalet, Denmark: a retrospective study comparing past and present rates and causes of revision and infection
    Mansson, Philip Kofoed
    Johansson, Sofia
    Ziebell, Morten
    Juhler, Marianne
    [J]. BMJ OPEN, 2017, 7 (01):
  • [10] Nguyen TA., 2015, DERMATOL ONLINE J, V21