Evaluation of Endotracheal Tube Cuff Pressure and the Use of Three Cuff Inflation Syringe Devices in Dogs

被引:10
作者
Hung, Wan-Chu [1 ,3 ]
Ko, Jeff C. [1 ]
Weil, Ann B. [1 ]
Weng, Hsin-Yi [2 ]
机构
[1] Purdue Univ, Dept Vet Clin Sci, Coll Vet Med, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Comparat Pathobiol, Coll Vet Med, W Lafayette, IN 47907 USA
[3] Univ Saskatchewan, Western Coll Vet Med, Dept Small Anim Clin Sci, Saskatoon, SK, Canada
关键词
endotracheal tube cuff pressure; endotracheal tube cuff inflation device; endotracheal tube cuff pressure monitoring; endotracheal tube cuff pressure measurement; dog; INTRACUFF PRESSURE; TRACHEAL NECROSIS; BLOOD-FLOW; VOLUME; INTUBATION; CATS; RISK;
D O I
10.3389/fvets.2020.00039
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Over-inflation of an endotracheal tube (ETT) cuff may lead to tracheal mucosal irritation, tracheal wall ischemia or necrosis, whereas under-inflation increases the risk of pulmonary aspiration as well as leaking anesthetic gas and polluting the environment. The objectives of this two-phase study were to (1) identify the incidence of improper ETT cuff inflation (both over- and under-inflation) using the minimum occlusive volume (MOV) technique coupled with a regular injectable syringe in the anesthetized dogs, and (2) evaluate the performance of two commercially available inflation syringe devices (Tru-Cuff and AG Cuffill (R)) with the regular injectable syringe in inflating the ETT cuff to a recommended safe cuff pressure range (20-30 cmH(2)O). Dogs undergoing general anesthesia at Purdue Veterinary Medicine Teaching Hospital were included. The ETT cuff pressure was assessed with an aneroid manometer after the syringe inflation. The results of the first objective showed that a total of 80 dogs enrolled and that 50 of these 80 dogs required ETT cuff inflation. Among the 50 dogs, only 14% had proper ETT cuff inflation; 76% of the ETT cuffs were over-inflated and 10% were under-inflated. Ninety dogs were enrolled for the second objective study and they were randomly and equally assigned to the three syringe device treatment groups. The results showed that 80% of the ETT cuffs were over-inflated in the regular injectable syringe treatment group, whereas only 6.7% and 3.3% ETT cuffs were over-inflated in the Tru-Cuff and AG Cuffill (R) syringe treatment groups, respectively. The AG Cuffill (R) syringe treatment group had a significantly (p < 0.05) higher percentage of properly inflated ETT cuffs (86.7%) compared to the other two groups (regular injectable syringe [3.3%]; Tru-Cuff syringe [50%]. We concluded that there was a high incidence of improper ETT cuff inflation when using MOV technique coupled with a regular injectable syringe. The use of an AG Cuffill (R) syringe significantly reduced improper ETT cuff inflation.
引用
收藏
页数:11
相关论文
共 39 条
  • [1] Tracheal necrosis following tracheal intubation in a dog
    Alderson, B.
    Senior, J. M.
    Dugdale, A. H. A.
    [J]. JOURNAL OF SMALL ANIMAL PRACTICE, 2006, 47 (12) : 754 - 756
  • [2] Altobelli N., 2017, Egan's fundamentals of respiratory care, V11th, P739
  • [3] [Anonymous], VET ANESTHESIA ANALG
  • [4] [Anonymous], SMALL ANIMAL ANESTHE
  • [5] AAHA Nutritional Assessment Guidelines for Dogs and Cats
    Baldwin, Kimberly
    Bartges, Joe
    Buffington, Tony
    Freeman, Lisa M.
    Grabow, Mary
    Legred, Julie
    Ostwald, Donald, Jr.
    [J]. JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2010, 46 (04) : 285 - 296
  • [6] Aspects of in vivo endotracheal tube intracuff pressure in cats
    Bird, Alice R.
    Bird, David J.
    McMillan, Matthew W.
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2019, 46 (01) : 55 - 63
  • [7] Evaluation of the endotracheal tube cuff pressure resulting from four different methods of inflation in dogs
    Briganti, Angela
    Portela, Diego A.
    Barsotti, Giovanni
    Romano, Marta
    Breghi, Gloria
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2012, 39 (05) : 488 - 494
  • [8] Risk factors for anaesthetic-related death in cats: results from the confidential enquiry into perioperative small animal fatalities (CEPSAF)
    Brodbelt, D. C.
    Pfeiffer, D. U.
    Young, L. E.
    Wood, J. L. N.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (05) : 617 - 623
  • [9] Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs
    Chenelle, Christopher T.
    Itagaki, Taiga
    Fisher, Daniel F.
    Berra, Lorenzo
    Kacmarek, Robert M.
    [J]. RESPIRATORY CARE, 2017, 62 (01) : 102 - 112
  • [10] COYNE BE, 1992, J AM VET MED ASSOC, V201, P768