Evaluation of Efficiency of Polymerization, Surface Roughness, Porosity and Adaptation of Flowable and Sculptable Bulk Fill Composite Resins

被引:7
作者
Gjorgievska, Elizabeta [1 ,2 ]
Oh, Daniel S. [2 ]
Haam, Daewon [2 ]
Gabric, Dragana [3 ]
Coleman, Nichola J. [4 ]
机构
[1] Univ Ss Cyril & Methodius, Fac Dent Med, Dept Paediat & Prevent Dent, Skopje 1000, North Macedonia
[2] Columbia Univ, Coll Dent Med, New York, NY 10032 USA
[3] Univ Zagreb, Clin Hosp Ctr, Sch Dent Med, Dept Oral Surg, Zagreb 10000, Croatia
[4] Univ Greenwich, Fac Engn & Sci, Chatham ME4 4TB, Kent, England
来源
MOLECULES | 2021年 / 26卷 / 17期
关键词
composite resin; bulk fill; polymerization; surface roughness; porosity; adaptation; VOIDS; CURE; CONVERSION; SHRINKAGE; DEPTH;
D O I
10.3390/molecules26175202
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new category of commercial bulk fill composite resins (CRs) enables the placement of 4-mm-thick layers as an alternative to the traditional time-consuming incremental technique. The purpose of the present study was to compare the efficiency of the polymerization, adaptation and porosity of two high-viscosity 'sculptable' bulk fill CRs (Filtek (TM) Bulk Fill (3M (TM) ESPE, St. Paul, MN, USA) and Tetric EvoCeram(R) Bulk Fill (Ivoclar Vivadent AG, Schwan, Liechtenstein)) and two low-viscosity 'flowable' bulk fill CRs (SureFil(R) SDR (TM) flow (Dentsply Sirona, Charlotte, NC, USA) and Tetric EvoFlow(R) Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein)). Cylindrical samples of the bulk fill CRs (4 mm height x 10 mm diameter) were analyzed by Fourier-transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM). Additionally, occlusal cavities were prepared in twelve extracted human molars and restored with the bulk fill CRs (n = 3 for each CR). The adaptation and porosity of the bulk fill CRs were evaluated by X-ray microcomputed tomography (mu CT) with a 3D morphometric analysis, and the adaptation was also analyzed by scanning electron microscopy (SEM) on longitudinal vestibulo-oral sections of the restored teeth. The AFM analysis demonstrated that the surface roughness of the SureFil(R) SDR (TM) flow was higher than that of the Tetric EvoFlow(R) Bulk Fill and that the surface roughness of Filtek (TM) Bulk Fill was higher than that of Tetric EvoCeram(R) Bulk Fill. mu CT and SEM confirmed that the flowable bulk fill CRs had excellent adaptation to the cavity walls. The 3D morphometric analysis showed the highest and lowest degrees of porosity in Filtek (TM) Bulk Fill and Tetric EvoFlow(R) Bulk Fill, respectively. In general, the flowable bulk fill CRs exhibited better adaptation, a higher efficiency of polymerization and lower porosity than the sculptable materials.
引用
收藏
页数:11
相关论文
共 36 条
[31]   One-year clinical evaluation of bulk-fill flowable vs. regular nanofilled composite in non-carious cervical lesions [J].
Canali, Gabriela D. ;
Ignacio, Sergio A. ;
Rached, Rodrigo N. ;
Souza, Evelise M. .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) :889-897
[32]   Evaluation of surface roughness and hardness of newer nanoposterior composite resins after immersion in food-simulating liquids [J].
Kumari, C. Meena ;
Bhat, K. Manohar ;
Bansal, Rahul ;
Singh, Nitika ;
Anupama, A. ;
Lavanya, T. .
CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (02) :289-293
[33]   Influence of Various Desensitizing Mouthrinses and Simulated Toothbrushing on Surface Roughness and Microhardness of Tetric N-Ceram Bulk-Fill Resin Composite: An In Vitro Study and Scanning Electron Microscope Analysis [J].
Gehlot, Paras Mull ;
Sudeep, Parvathi ;
Manjunath, Vinutha ;
Annapoorna, B. M. ;
Prasada, L. Krishna ;
Nandlal, Bhojraj .
EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (04) :820-827
[34]   Surface Roughness and Color Stability of Conventional and Bulk-Fill Resin Composite with S-PRG Fillers After Coffee Exposure: An in-vitro Study [J].
Janisch, Fabiano Augusto Dos Santos ;
Aguilar, Milagros Falcon ;
Aguiar, Flavio Henrique Baggio ;
Franca, Fabiana Mantovani Gomes ;
Basting, Roberta Tarkany ;
Vieira-Junior, Waldemir Francisco .
CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2025, 17 :21-29
[35]   In-vitro evaluation of fracture resistance of teeth restored with different high-viscosity glass ionomer restorative materials and bulk-fill composite resins [J].
Nezir, Merve ;
Ozcan, Suat .
CLINICAL ORAL INVESTIGATIONS, 2024, 28 (06)
[36]   The Effect of Dentifrice on Micro-Hardness, Surface Gloss, and Micro-Roughness of Nano Filled Conventional and Bulk-Fill Polymer Composite-A Micro Indentation and Profilometric Study [J].
Binhasan, Mashael ;
Solimanie, Abdulilah H. ;
Almuammar, Khalid S. ;
Alnajres, Ahmed R. ;
Alhamdan, Mai M. ;
Al Ahdal, Khold ;
Alfaawaz, Yasser F. ;
Ali, Khalid ;
Vohra, Fahim ;
Abduljabbar, Tariq .
MATERIALS, 2022, 15 (12)