Performance of an adiabatic cross-flow liquid-desiccant absorber inside a refrigerated warehouse

被引:11
作者
Pineda, Sergio M. [1 ]
Diaz, Gerardo [1 ]
机构
[1] Univ Calif Merced, Sch Engn, Merced, CA 95343 USA
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2011年 / 34卷 / 01期
关键词
Cold storage; Desiccant; Defrosting; Energy consumption; Reduction; Moisture; SYSTEM; AIR; DEHUMIDIFICATION;
D O I
10.1016/j.ijrefrig.2010.08.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid-desiccant systems have been extensively studied as a way of reducing the latent load on air conditioning systems. Most of the studies have targeted the removal of moisture from air at ambient conditions. The literature about the use of liquid desiccants in low temperature applications is scarce. In this study, a small-scale liquid-desiccant absorber is installed inside a commercial refrigerated warehouse. Its performance under realistic operating conditions inside a pre-cooling room is analyzed. The results show that the dew point temperature of the air downstream of the absorber is comparable to the evaporator surface temperature suggesting the potential to delay the formation of ice on the cooling coil. An internal heat exchanger is used to lower the temperature of the inlet liquid-desiccant flow to the absorber and the regeneration process is performed using only ambient air. The analysis of the reduction in water and energy consumption for a scaled-up system is also performed. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
[41]   Dynamic cross-flow filtration: enhanced continuous small-scale solid-liquid separation [J].
Gursch, Johannes ;
Hohl, Roland ;
Dujmovic, Diana ;
Brozio, Joerg ;
Krumme, Markus ;
Rasenack, Norbert ;
Khinast, Johannes .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2016, 42 (06) :977-984
[42]   Analytical model based performance evaluation, sizing and coupling flow optimization of liquid desiccant run-around membrane energy exchanger systems [J].
Ge, Gaoming ;
Moghaddam, Davood Ghadiri ;
Namvar, Ramin ;
Simonson, Carey J. ;
Besant, Robert W. .
ENERGY AND BUILDINGS, 2013, 62 :248-257
[43]   Optimizing the effect of concentration and flow rate of water/MWCNTs nanofluid on the performance of a forced draft cross-flow cooling tower [J].
Javadpour, Reza ;
Heris, Saeed Zeinali ;
Mohammadfam, Yaghoub .
ENERGY, 2021, 217
[44]   Performance comparison of different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers [J].
Ali Pakari ;
Saud Ghani .
Journal of Thermal Analysis and Calorimetry, 2022, 147 :10439-10459
[45]   Experimental investigations on the performance characteristics of plastic surfaces for developing low flow falling film liquid desiccant regenerators [J].
Khan, Rehan ;
Kumar, Ritunesh ;
Ma, Zhenjun .
SOLAR ENERGY, 2022, 236 :356-368
[46]   Performance comparison of different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers [J].
Pakari, Ali ;
Ghani, Saud .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (19) :10439-10459
[47]   Performance analysis of different flow types of internally-cooled membrane-based liquid desiccant dehumidifiers [J].
Li, Wei ;
Yao, Ye .
ENERGY, 2021, 228
[48]   Numerical study on the hydrodynamic performance and wake dynamics of propulsive wing propulsors with different cross-flow fans [J].
Lu, Jiaxin ;
Lu, Yang ;
Wang, Junjie ;
Xu, Xice ;
Shao, Mengxue ;
Tang, Zhengfei .
PHYSICS OF FLUIDS, 2024, 36 (01)
[49]   Cooling performance measurement of two cross-flow indirect evaporative coolers in general and regenerative operation modes [J].
Kim, Hui-Jeong ;
Ham, Sang-Woo ;
Yoon, Dong-Seob ;
Jeong, Jae-Weon .
APPLIED ENERGY, 2017, 195 :268-277
[50]   Numerical simulation and theoretical analysis of heat and mass transfer in a cross flow liquid desiccant air dehumidifier packed with honeycomb paper [J].
Dai, YJ ;
Zhang, HF .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) :1343-1356