Determination of lansoprazole in pharmaceuticals using flow injection with rhodamine 6G-diperiodatoargentate(III) chemiluminescence detection

被引:2
|
作者
Khan, Muhammad Shoaib [1 ]
Asghar, Muhammad [1 ]
Yaqoob, Mohammed [1 ]
Ali, Samar [1 ]
Shah, Syed Haider [2 ]
Siddiqui, Masood Ahmed [1 ]
机构
[1] Univ Balochistan, Dept Chem, Sariab Rd, Quetta 87300, Pakistan
[2] Univ Loralai, Dean Basic Sci, Loralai, Pakistan
关键词
chemiluminescence; diperiodatoargentate(III); flow injection analysis; lansoprazole; pharmaceutical formulations; rhodamine; 6G; PROTON PUMP INHIBITORS; LUMINOL-AG(III) COMPLEX; HUMAN PLASMA; OMEPRAZOLE; 6G; DIPERIODATOARGENTATE(III); OXIDATION; DRUGS; ACIDS;
D O I
10.1002/bio.4266
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemiluminescence (CL) method based on rhodamine 6G (R6G)-diperiodatoargentate(III) (silver(III) complex) reaction in acid solution is reported for the determination of lansoprazole (LNP) combined with a flow injection (FI) technique. The most likely mechanism for CL reaction was elucidated considering reported data, spectrophotometric and spectrofluorimetric studies. The weak CL reaction between R6G and silver(III) complex could be magnanimously increased in the presence of LNP with a limit of detection (LOD) of 0.002 mg L-1 (S/N = 3), a linear range of 0.01 to 10 mg L-1 (R-2 = 0.9997, n = 7), a relative standard deviation (RSD) of 1.2 to 3.2% (n = 4) and an injection throughput of 140 h(-1). No interference activity of commonly found excipients in LNP was detected. After LNP extraction from pharmaceutical samples, the recovery rate ranging from 93 to 110% (RSD, 1.4-3.3%, n = 4) was calculated. The results of the proposed flow CL method were assessed with a spectrophotometric approach applying paired Student's t-test and the calculated value (0.178) was lower than the distributed value (2.20) at a 95% confidence limit.
引用
收藏
页码:1126 / 1134
页数:9
相关论文
共 50 条
  • [21] Determination of Genistein by Flow-injection Chemiluminescence Method Based on Ferricyanide Oxidation Sensitized by Rhodamine 6G
    Wang, Huili
    Han, Suqin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (09) : 1130 - 1136
  • [22] Determination of Thiram and Aminocarb Pesticides in Natural Water Samples Using Flow Injection with Tris(2,2′-bipyridyl)-ruthenium(II)-diperiodatoargentate(III) Chemiluminescence Detection
    Mohammad Asghar
    Mohammad Yaqoob
    Naheed Haque
    Abdul Nabi
    Analytical Sciences, 2013, 29 : 1061 - 1066
  • [23] Sensitive determination of ketoprofen using flow injection with chemiluminescence detection
    Zhuang, Yafeng
    Song, Hengli
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 824 - 828
  • [24] Determination of Mancozeb and Maneb using flow injection chemiluminescence detection
    Asghar, Muhammad
    Yaqoob, Mohammad
    Munawar, Nusrat
    Nabi, Abdul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (11) : 2586 - 2606
  • [25] DETERMINATION OF AMOXICILLIN, AMPICILLIN AND PENICILLIN G USING A FLOW INJECTION ANALYSIS METHOD WITH CHEMILUMINESCENCE DETECTION
    Chivulescu, Alexandru Ioan
    Doni, Mihaela Badea
    Cheregi, Mihaela-Carmen
    Danet, Andrei Florin
    REVUE ROUMAINE DE CHIMIE, 2011, 56 (03) : 247 - +
  • [26] Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2008, 23 (03) : 144 - 149
  • [27] Determination of oxytetracycline by flow injection with chemiluminescence detection
    Guo, LQ
    Xie, ZH
    Bian, XT
    Lin, XC
    Zhang, WL
    Liu, XH
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 129 - 134
  • [28] Determination of epinephrine by flow-injection analysis using luminol-hexacyanoferrate(III) chemiluminescence detection
    Kojlo, A
    Nalewajko, E
    CHEMIA ANALITYCZNA, 2004, 49 (05): : 653 - 663
  • [29] Flow Injection Chemiluminescence Determination of Retinol and -Tocopherol in Blood Serum and Pharmaceuticals
    Asgher, Mohammad
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 12 - 24
  • [30] Analytical Applications of Flow Injection Chemiluminescence for the Determination of Pharmaceuticals-A Review
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    CURRENT PHARMACEUTICAL ANALYSIS, 2013, 9 (04) : 363 - 395