High-speed simultaneous ion-exclusion/cation-exchange chromatography of anions and cations on a weakly acidic cation-exchange resin column

被引:47
作者
Mori, M
Tanaka, K
Helaleh, MIH
Xu, Q
Ikedo, M
Ogura, Y
Sato, S
Hu, WZ
Hasebe, K
Haddad, PR
机构
[1] Natl Inst Adv Ind Sci & Technol Seto, Aichi 4890884, Japan
[2] Chubu Univ, Grad Sch, Aichi 4890884, Japan
[3] Tosoh Corp, Yamaguchi 7468501, Japan
[4] Hokkaido Univ, Grad Sch Sci, Div Chem, Sapporo, Hokkaido 0600810, Japan
[5] Hokkaido Univ, Grad Sch Environm Earth Sci, Div Sci Mat, Sapporo, Hokkaido 0600810, Japan
[6] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
water analysis; environmental analysis; tartaric acid; inorganic anions; inorganic cations;
D O I
10.1016/S0021-9673(03)00631-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The simultaneous ion-exclusion/cation-exchange separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin of 3 mum particle size was used to achieve the simultaneous high-speed separation of anions and cations (Cl-, NO3-, SO42-, Na+, K+, NH4+, Ca2+ and Mg2+) commonly found in environmental samples. The high-speed simultaneous separation is based on a combination of the ion-exclusion mechanism for the anions and the cation-exchange mechanism for cations. The complete separation of the anions and cations was achieved in 5 min by elution with 15 mM tartaric acid-2.5 mM 18-crown-6 at a flow-rate of 1.5 ml/min. Detection limits at S/N = 3 ranged from 0.36 to 0.68 muM for anions and 0.63-0.99 muM for cations. This method has been applied to the simultaneous determination of anions and cations in several environmental waters with satisfactory results. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 15 条
[1]   Simultaneous ion-exclusion chromatography and cation-exchange chromatography of anions and cations in environmental water samples on a weakly acidic cation-exchange resin by elution with pyridine-2,6-dicarboxylic acid [J].
Ding, MY ;
Tanaka, K ;
Hu, WZ ;
Hasebe, K ;
Haddad, PR .
ANALYST, 2001, 126 (05) :567-570
[2]   THERMODYNAMIC AND KINETIC DATA FOR CATION MACROCYCLE INTERACTION [J].
IZATT, RM ;
BRADSHAW, JS ;
NIELSEN, SA ;
LAMB, JD ;
CHRISTENSEN, JJ .
CHEMICAL REVIEWS, 1985, 85 (04) :271-339
[3]   NOVEL WEAK ACID CATION-EXCHANGE COLUMN [J].
JENSEN, D ;
WEISS, J ;
REY, MA ;
POHL, CA .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :65-71
[4]   POLYMER-COATED CATION-EXCHANGE STATIONARY PHASES ON THE BASIS OF SILICA [J].
KOLLA, P ;
KOHLER, J ;
SCHOMBURG, G .
CHROMATOGRAPHIA, 1987, 23 (07) :465-472
[5]  
Kwon S. M., 1999, ENV ENG RES, V4, P223
[6]   Simultaneous determination of anions and cations by ion-exclusion chromatography-cation-exchange chromatography with tartaric acid/18-crown-6 as eluent [J].
Kwon, SM ;
Lee, KP ;
Tanaka, K ;
Ohta, K .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :79-84
[7]   Simultaneous determination of common mono- and divalent cations in natural water samples by conductimetric detection ion chromatography with an unmodified silica gel column and oxalic acid 18-crown-6 as eluent [J].
Ohta, K ;
Tanaka, K .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :265-273
[8]   SIMULTANEOUS ION-EXCLUSION CHROMATOGRAPHY CATION-EXCHANGE CHROMATOGRAPHY WITH CONDUCTIMETRIC DETECTION OF ANIONS AND CATIONS IN ACID-RAIN WATERS [J].
TANAKA, K ;
OHTA, K ;
FRITZ, JS ;
MATSUSHITA, S ;
MIYANAGA, A .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :239-248
[9]   Acid-rain monitoring in East Asia with a portable-type ion-exclusion-cation-exchange chromatographic analyzer [J].
Tanaka, K ;
Ohta, K ;
Haddad, PR ;
Fritz, JS ;
Lee, KP ;
Hasebe, K ;
Ieuji, A ;
Miyanaga, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :311-317
[10]   High-performance ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin [J].
Tanaka, K ;
Ohta, K ;
Haddad, PR ;
Fritz, JS ;
Miyanaga, A ;
Hu, WZ ;
Hasebe, K ;
Lee, KP ;
Sarzanini, C .
JOURNAL OF CHROMATOGRAPHY A, 2001, 920 (1-2) :239-245