Effect of Needle Size and Type, Reuse of Needles, Insertion Speed, and Removal of Hair on Contamination of Joints with Tissue Debris and Hair after Arthrocentesis

被引:22
作者
Adams, Stephen B. [1 ]
Moore, George E. [2 ]
Elrashidy, Mohammed [1 ]
Mohamed, Ahmed [2 ]
Snyder, Paul W. [2 ]
机构
[1] Purdue Univ, Sch Vet Med, Dept Vet Clin Sci, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Vet Med, Dept Comparat Pathobiol, W Lafayette, IN 47907 USA
关键词
SEPTIC ARTHRITIS; SKIN; INJECTIONS;
D O I
10.1111/j.1532-950X.2010.00649.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To assess joint contamination with tissue and hair after arthrocentesis of equine fetlock joints. Study Design Experimental. Animals Limb specimens from 8 equine cadavers. Procedures Soft tissues including the joint capsule were harvested from the dorsal aspect of the fetlock joints and mounted on a wooden frame. Needles inserted through the joint tissue preparation were flushed into tissue culture plates that were examined for tissue and hair debris. Variables evaluated were gauge and type of needle (16, 18, 20, and 22 G sharp disposable needles and 20 G disposable spinal needles with stylet), number of times each needle was used (1, 2, 3, 4), length of hair (unclipped, clipped, shaved with razor), and needle insertion speed (fast, slow). Descriptive and statistical evaluations were performed. Results Tissue contamination was identified in 1145 of 1260 wells and hair contamination was identified in 384 of 1260 wells. Twenty gauge needles inserted through unclipped hair resulted in the least amount of hair contamination. Compared with 20 G needles with fast insertion 1 time through unclipped hair the odds ratios for contamination with hair were significantly greater for 16 G sharp disposable needles, 20 G spinal needles, clipped hair, shaved hair, and reuse of the needles. Spinal needles inserted through unclipped hair transferred many long hairs into the joint space. Conclusion Reuse of needles for arthrocentesis should be avoided. Removal of hair is not indicated for arthrocentesis with sharp injection needles but is recommended when using spinal needles with stylets. Clinical Relevance Joint contamination with hair and tissue debris will be decreased by specific needle insertion techniques. Decreased contamination of joints may reduce the frequency of joint infections after arthrocentesis.
引用
收藏
页码:667 / 673
页数:7
相关论文
共 19 条
  • [11] Evaluation of a balloon constant rate infusion system for treatment of septic arthritis, septic tenosynovitis, and contaminated synovial wounds: 23 cases (2002-2005)
    Meagher, DT
    Latimer, FG
    Sutter, WW
    Saville, WJA
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2006, 228 (12): : 1930 - 1934
  • [12] Reina M A, 1995, Rev Esp Anestesiol Reanim, V42, P383
  • [13] CLOSED SUCTION DRAINAGE IN THE TREATMENT OF INFECTIOUS ARTHRITIS OF THE EQUINE TARSOCRURAL JOINT
    ROSS, MW
    ORSINI, JA
    RICHARDSON, DW
    MARTIN, BB
    [J]. VETERINARY SURGERY, 1991, 20 (01) : 21 - 29
  • [14] HAIRS CAUSING PULMONARY EMBOLI - RARE COMPLICATION IN LONG-TERM INTRAVENOUS STUDIES IN DOGS
    SCHNEIDER, P
    PAPPRITZ, G
    [J]. VETERINARY PATHOLOGY, 1976, 13 (05) : 394 - 400
  • [15] A RETROSPECTIVE STUDY OF 192 HORSES AFFECTED WITH SEPTIC ARTHRITIS TENOSYNOVITIS
    SCHNEIDER, RK
    BRAMLAGE, LR
    MOORE, RM
    MECKLENBURG, LM
    KOHN, CW
    GABEL, AA
    [J]. EQUINE VETERINARY JOURNAL, 1992, 24 (06) : 436 - 442
  • [16] SCOTT DW, 2003, EQUINE DERMATOLOGY, P146
  • [17] Scott DW., 2003, Equine Dermatology, P1
  • [18] MICROBIAL-CONTAMINATION OF PHARMACEUTICAL INJECTIONS AT THE SITE OF ADMINISTRATION
    WHYTE, W
    HILDITCH, TE
    BELL, NDS
    [J]. JOURNAL OF CLINICAL AND HOSPITAL PHARMACY, 1984, 9 (01): : 61 - 67
  • [19] Endoscopic surgery in the treatment of contaminated and infected synovial cavities
    Wright, IM
    Smith, MRW
    Humphrey, DJ
    Eaton-Evans, TCJ
    Hillyer, MH
    [J]. EQUINE VETERINARY JOURNAL, 2003, 35 (06) : 613 - 619