Effect of Needle Size and Type, Reuse of Needles, Insertion Speed, and Removal of Hair on Contamination of Joints with Tissue Debris and Hair after Arthrocentesis

被引:22
作者
Adams, Stephen B. [1 ]
Moore, George E. [2 ]
Elrashidy, Mohammed [1 ]
Mohamed, Ahmed [2 ]
Snyder, Paul W. [2 ]
机构
[1] Purdue Univ, Sch Vet Med, Dept Vet Clin Sci, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Vet Med, Dept Comparat Pathobiol, W Lafayette, IN 47907 USA
关键词
SEPTIC ARTHRITIS; SKIN; INJECTIONS;
D O I
10.1111/j.1532-950X.2010.00649.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To assess joint contamination with tissue and hair after arthrocentesis of equine fetlock joints. Study Design Experimental. Animals Limb specimens from 8 equine cadavers. Procedures Soft tissues including the joint capsule were harvested from the dorsal aspect of the fetlock joints and mounted on a wooden frame. Needles inserted through the joint tissue preparation were flushed into tissue culture plates that were examined for tissue and hair debris. Variables evaluated were gauge and type of needle (16, 18, 20, and 22 G sharp disposable needles and 20 G disposable spinal needles with stylet), number of times each needle was used (1, 2, 3, 4), length of hair (unclipped, clipped, shaved with razor), and needle insertion speed (fast, slow). Descriptive and statistical evaluations were performed. Results Tissue contamination was identified in 1145 of 1260 wells and hair contamination was identified in 384 of 1260 wells. Twenty gauge needles inserted through unclipped hair resulted in the least amount of hair contamination. Compared with 20 G needles with fast insertion 1 time through unclipped hair the odds ratios for contamination with hair were significantly greater for 16 G sharp disposable needles, 20 G spinal needles, clipped hair, shaved hair, and reuse of the needles. Spinal needles inserted through unclipped hair transferred many long hairs into the joint space. Conclusion Reuse of needles for arthrocentesis should be avoided. Removal of hair is not indicated for arthrocentesis with sharp injection needles but is recommended when using spinal needles with stylets. Clinical Relevance Joint contamination with hair and tissue debris will be decreased by specific needle insertion techniques. Decreased contamination of joints may reduce the frequency of joint infections after arthrocentesis.
引用
收藏
页码:667 / 673
页数:7
相关论文
共 19 条
  • [1] Bassage I I., 2003, Diagnosis and Management of Lameness in the Horse. pp, P93
  • [2] SPINAL NEEDLE AS A CARRIER OF FOREIGN MATERIAL
    BRANDUS, V
    [J]. CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1968, 15 (02) : 197 - &
  • [3] Buchta C, 2005, WIEN KLIN WOCHENSCHR, V117, P141, DOI 10.1007/s00508-005-0310-6
  • [4] Septic arthritis in Iceland 1990-2002:: increasing incidence due to iatrogenic infections
    Geirsson, A. J.
    Statkevicius, S.
    Vikingsson, A.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2008, 67 (05) : 638 - 643
  • [5] Glaser DL, 2001, P AM ACAD ORTHOP SUR, V68, P130
  • [6] Evaluation of skin bacterial flora before and after aseptic preparation of clipped and nonclipped arthrocentesis sites in horses
    Hague, BA
    Honnas, CM
    Simpson, RB
    Peloso, JG
    [J]. VETERINARY SURGERY, 1997, 26 (02) : 121 - 125
  • [7] HASLOCK I, 1995, BRIT J RHEUMATOL, V34, P449
  • [8] Hoffman P, 2001, Acupunct Med, V19, P112
  • [9] KAST A, 1995, BERL MUNCH TIERARZTL, V108, P61
  • [10] SEPTIC ARTHRITIS IN 15 STANDARD-BRED RACEHORSES AFTER INTRAARTICULAR INJECTION
    LAPOINTE, JM
    LAVERTY, S
    LAVOIE, JP
    [J]. EQUINE VETERINARY JOURNAL, 1992, 24 (06) : 430 - 434