Gallium trace on-line preconcentration/separation and determination using a polyurethane foam mini-column and flame atomic absorption spectrometry. Application in aluminum alloys, natural waters and urine

被引:41
作者
Antheraidis, AN [1 ]
Zachariadis, GA [1 ]
Stratis, JA [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
gallium; atomic absorption spectrometry; on-line preconcentration; polyurethane foam;
D O I
10.1016/S0039-9140(03)00156-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective flow injection time-based method for on-line preconcentration/separation and determination of gallium by flame atomic absorption spectrometry at trace levels was developed. The on-line formed gallium chloride complex is sorbed onto a polyether-type polyurethane foam mini-column, followed by on-line quantitative elution with isobutyl methyl ketone and direct introduction into the flame pneumatic nebulizer of the atomic absorption spectrometer. All chemical and flow variables of the system as,well as the possible interferences were studied. The manner of strong HCl solutions propulsion was investigated and established using a combination of two displacement bottles. For 90 s preconcentration time, a sample frequency of 28 h(-1), an enhancement factor of 40, a detection limit of 6 mug 1(-1) and a precision expressed as relative standard deviation (s,) of 3.3% (at 1.00 mg 1(-1)) were achieved. The calibration curve is linear over the concentration range 0.02-3.00 mg 1(-1). The accuracy of the developed method was sufficient and evaluated by the analysis of a silicon-aluminum alloy standard reference material. Finally, it was successfully applied to gallium determination in commercial aluminum alloys, natural waters and urine. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:929 / 936
页数:8
相关论文
共 27 条
[1]  
[Anonymous], 1989, FLOW INJECTION ANAL
[2]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[3]   ABSORPTION BY POLYURETHANE FOAMS - NEW METHOD OF SEPARATION [J].
BOWEN, HJM .
JOURNAL OF THE CHEMICAL SOCIETY A -INORGANIC PHYSICAL THEORETICAL, 1970, (07) :1082-&
[4]   TRENDS IN USING RESILIENT POLYURETHANE FOAMS AS SORBENTS IN ANALYTICAL-CHEMISTRY [J].
BRAUN, T .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 314 (07) :652-656
[5]   POLYURETHANE FOAMS AND MICROSPHERES IN ANALYTICAL-CHEMISTRY - IMPROVED LIQUID-SOLID, GAS-SOLID AND LIQUID-LIQUID CONTACT VIA A NEW GEOMETRY OF SOLID-PHASE [J].
BRAUN, T ;
FARAG, AB .
ANALYTICA CHIMICA ACTA, 1978, 99 (01) :1-36
[6]  
Braun T., 1985, POLYURETHANE FOAM SO
[7]  
CARVALHO MS, 1993, THESIS PONTIFICIA U
[8]   Flow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC) [J].
Cassella, RJ ;
Salim, VA ;
Jesuíno, LS ;
Santelli, RE ;
Ferreira, SLC ;
de Carvalho, MS .
TALANTA, 2001, 54 (01) :61-67
[9]   Selectivity enhancement in spectrophotometry: on-line interference suppression using polyurethane foam minicolumn for aluminum determination with Methyl Thymol Blue [J].
Cassella, RJ ;
Santelli, RE ;
Branco, AG ;
Lemos, VA ;
Ferreira, SLC ;
de Carvalho, MS .
ANALYST, 1999, 124 (05) :805-808
[10]   On-line preconcentration system for flame atomic absorption spectrometry using unloaded polyurethane foam: determination of zinc in waters and biological materials [J].
Cassella, RJ ;
Bitencourt, DT ;
Branco, AG ;
Ferreira, SLC ;
de Jesus, DS ;
de Carvalho, MS ;
Santelli, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1749-1753