A novel procedure for daily measurements of hemodynamical, hematological, and biochemical parameters in conscious unrestrained rats

被引:9
作者
Blouin, A
Molez, S
Pham, D
Ayach, B
Dussault, P
Escher, E
Jeng, AY
Battistini, B
机构
[1] Univ Laval, Hop Laval, Dept Med, Inst Cardiol & Pneumol,Ctr Rech, St Foy, PQ G1V 4G5, Canada
[2] Univ Sherbrooke, Fac Med, Inst Pharmacol, Sherbrooke, PQ J1H 5N4, Canada
[3] Novartis Inst Biomed Res, Summit, NJ 07901 USA
关键词
chronic catheterization; infusion; blood sampling; conscious; rat; blood pressure; bilirubin; creatinine; endothelin; nitric oxide;
D O I
10.1016/S1056-8719(01)00108-3
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Accurate and chronic measurements of various parameters in conscious animals are fundamental for depicting pathological chronic conditions and their etiology in many experimental models, but they are often difficult to achieve. The aim of the present work was to develop and describe step-by-step a reproducible surgical procedure and daily manipulations for continuous, chronic use of conscious rats as models towards a better understanding of various cardiovascular and renal diseases and the testing of novel pharmacological drugs. The complete apparatus involved the use of a series of specialized devices (harness, rotating swivel, revolving arm) supporting a flexible, permanently implanted vascular catheter into the left femoral artery up to the abdominal aorta connected to a miniaturized individual peristaltic pump for delivering fluid at a constant rate. Such a set-up also enabled easy, quick, and reproducible daily blood sampling for the evaluation of more than 20 parameters, including the monitoring of heart rate (HR) and blood pressure in freely moving conscious rats. The overall success and survival rate reached 98% over 14 days and could be extended further This model represents a much needed and valuable advance in surgical research techniques to evaluate the hemodynamic, hematological, biochemical, pharmacokinetic, and toxicological profile of any new drugs over time in conscious animal models such as rats. What makes this procedure satisfactory is the long-term reliable arterial access and reproducibility of the methodological approach for accurate and continuous measurements, minimizing the stress or invasiveness associated with the use of currently employed systems. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:489 / 505
页数:17
相关论文
共 59 条
  • [1] ACLAND RD, 1980, MICROSURGERY PRACTIC, P38
  • [2] Telemetry for cardiovascular monitoring in a pharmacological study - New approaches to data analysis
    Anderson, NH
    Devlin, AM
    Graham, D
    Morton, JJ
    Hamilton, CA
    Reid, JL
    Schork, NJ
    Dominiczak, AF
    [J]. HYPERTENSION, 1999, 33 (01) : 248 - 255
  • [3] Archer R K, 1977, COMP CLIN HAEMATOLOG
  • [4] SIMPLE RELIABLE METHOD FOR CHRONIC CANNULATION OF THE JUGULAR VEIN FOR PHARMACOKINETIC STUDIES IN RATS
    BAKAR, SK
    NIAZI, S
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (09) : 1027 - 1029
  • [5] Radiotelemetric versus externalized catheter monitoring of blood pressure: Effect of vasopressin in spontaneous hypertension
    Balakrishnan, S
    Tatchum-Talom, R
    McNeill, JR
    [J]. JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1998, 40 (02) : 87 - 93
  • [6] TELEMETRIC MONITORING OF CARDIOVASCULAR PARAMETERS IN CONSCIOUS SPONTANEOUSLY HYPERTENSIVE RATS
    BAZIL, MK
    KRULAN, C
    WEBB, RL
    [J]. JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1993, 22 (06) : 897 - 905
  • [7] Boyd J W, 1983, Vet Clin Pathol, V12, P9, DOI 10.1111/j.1939-165X.1983.tb00609.x
  • [8] BRANDSTAETTER J, 1977, LAB ANIM SCI, V27, P999
  • [9] A NEW METHOD FOR CONTINUOUS CHRONIC MEASUREMENT AND RECORDING OF BLOOD-PRESSURE, HEART-RATE AND ACTIVITY IN THE RAT VIA RADIOTELEMETRY
    BROCKWAY, BP
    MILLS, PA
    AZAR, SH
    [J]. CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1991, 13 (05) : 885 - 895
  • [10] INCREASED ENDOTHELIN EXCRETION IN RATS WITH RENAL-FAILURE INDUCED BY PARTIAL NEPHRECTOMY
    BROOKS, DP
    CONTINO, LC
    STORER, B
    OHLSTEIN, EH
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1991, 104 (04) : 987 - 989