DOSIMETRIC IMPACT OF INTERFRACTION CATHETER MOVEMENT IN HIGH-DOSE RATE PROSTATE BRACHYTHERAPY

被引:33
作者
Foster, William [1 ]
Cunha, J. Adam M. [1 ]
Hsu, I-Chow [1 ]
Weinberg, Vivan [1 ]
Krishnamurthy, Devan [1 ]
Pouliot, Jean [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2011年 / 80卷 / 01期
关键词
HDR brachytherapy; Prostate; Interfraction catheter displacement; Dosimetry; EXTERNAL-BEAM RADIOTHERAPY; HDR-BRACHYTHERAPY; CANCER; OPTIMIZATION; IMPLANT; BOOST;
D O I
10.1016/j.ijrobp.2010.01.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the impact of interfraction catheter movement on dosimetry in prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Fifteen patients were treated with fractionated HDR brachytherapy. Implants were performed on day 1 under transrectal ultrasound guidance. A computed tomography (CT) scan was performed. Inverse planning simulated annealing was used for treatment planning. The first fraction was delivered on day 1. A cone beam CT (CBCT) was performed on day 2 before the second fraction was given. A fusion of the CBCT and CT was performed using intraprostatic gold markers as landmarks. Initial prostate and urethra contours were transferred to the CBCT images. Bladder and rectum contours were drawn, and catheters were digitized on the CBCT. The planned treatment was applied to the CBCT dataset, and dosimetry was analyzed and compared to the initial dose distribution. This process was repeated after a reoptimization was performed, using the same constraints used on day 1. Results: Mean interfraction catheter displacement was 5.1 mm. When we used the initial plan on day 2, the mean prostate V100 (volume receiving 100 Gy or more) decreased from 93.8% to 76.2% (p < 0.01). Rectal V75 went from 0.75 cm(3) to 1.49 cm(3) (p < 0.01). A reoptimization resulted in a mean prostate V100 of 88.1%, closer to the initial plan (p = 0.05). Mean rectal V75 was also improved with a value of 0.59 cm(3). There was no significant change in bladder and urethra dose on day 2. Conclusions: A mean interfraction catheter displacement of 5.1 mm results in a significant decrease in prostate V100 And an increase in rectum dose. A reoptimization before the second treatment improves dose distribution. (C) 2011 Elsevier Inc.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [31] Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements
    Poder, Joel
    Whitaker, May
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (03) : 203 - 209
  • [32] A surrogate urethra for real-time planning of high-dose-rate prostate brachytherapy
    Halperin, Heather
    Hilts, Michelle
    Crook, Juanita
    Batchelar, Deidre
    Tisseverasinghe, Steven
    Tetreault-LaFlamme, Audrey
    Bachand, Francois
    BRACHYTHERAPY, 2019, 18 (05) : 675 - 682
  • [33] Combining theoretical potential and advanced technology in high-dose rate brachytherapy boost therapy for prostate cancer
    Zaorsky, Nicholas G.
    Den, Robert B.
    Doyle, Laura A.
    Dicker, Adam P.
    Hurwitz, Mark D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (06) : 751 - 763
  • [34] Real-time in vivo dosimetry in high dose rate prostate brachytherapy
    Mason, Josh
    Mamo, Arielle
    AI-Qaisieh, Bashar
    Henry, Ann M.
    Bownes, Peter
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 333 - 338
  • [35] Validation of MRI to TRUS registration for high-dose-rate prostate brachytherapy
    Poulin, Eric
    Boudam, Karim
    Pinter, Csaba
    Kadoury, Samuel
    Lasso, Andras
    Fichtinger, Gabor
    Menard, Cynthia
    BRACHYTHERAPY, 2018, 17 (02) : 283 - 290
  • [36] Dosimetric impact of source-positioning uncertainty in high-dose-rate balloon brachytherapy of breast cancer
    Kim, Yongbok
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (05) : 387 - 396
  • [37] Methods of verifying the output of the treatment planning system used for high dose rate (HDR) prostate brachytherapy
    Huckle, Aaron
    Al-Qaisieh, Bashar
    Bownes, Peter
    RADIOTHERAPY AND ONCOLOGY, 2012, 103 (02) : 261 - 265
  • [38] Previous transurethral resection of the prostate is not a contraindication to high-dose rate brachytherapy for prostate cancer
    Luo, Hao Lun
    Fang, Fu Min
    Chuang, Yao Chi
    Chiang, Po Hui
    BJU INTERNATIONAL, 2009, 104 (11) : 1620 - 1623
  • [39] Bi-objective optimization of catheter positions for high-dose-rate prostate brachytherapy
    van der Meer, Marjolein C.
    Bosman, Peter A. N.
    Niatsetski, Yury
    Alderliesten, Tanja
    van Wieringen, Niek
    Pieters, Bradley R.
    Bel, Arjan
    MEDICAL PHYSICS, 2020, 47 (12) : 6077 - 6086
  • [40] A dosimetric study of polyethylene glycol hydrogel in 200 prostate cancer patients treated with high-dose rate brachytherapy ± intensity modulated radiation therapy
    Strom, Tobin J.
    Wilder, Richard B.
    Fernandez, Daniel C.
    Mellon, Eric A.
    Saini, Amarjit S.
    Hunt, Dylan C.
    Pow-Sang, Julio M.
    Spiess, Phillipe E.
    Sexton, Wade J.
    Poch, Michael A.
    Biagioli, Matthew C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 (01) : 126 - 131