摘要
Purpose: To evaluate the impact of interfraction catheter movement on dosimetry in prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Fifteen patients were treated with fractionated HDR brachytherapy. Implants were performed on day 1 under transrectal ultrasound guidance. A computed tomography (CT) scan was performed. Inverse planning simulated annealing was used for treatment planning. The first fraction was delivered on day 1. A cone beam CT (CBCT) was performed on day 2 before the second fraction was given. A fusion of the CBCT and CT was performed using intraprostatic gold markers as landmarks. Initial prostate and urethra contours were transferred to the CBCT images. Bladder and rectum contours were drawn, and catheters were digitized on the CBCT. The planned treatment was applied to the CBCT dataset, and dosimetry was analyzed and compared to the initial dose distribution. This process was repeated after a reoptimization was performed, using the same constraints used on day 1. Results: Mean interfraction catheter displacement was 5.1 mm. When we used the initial plan on day 2, the mean prostate V100 (volume receiving 100 Gy or more) decreased from 93.8% to 76.2% (p < 0.01). Rectal V75 went from 0.75 cm(3) to 1.49 cm(3) (p < 0.01). A reoptimization resulted in a mean prostate V100 of 88.1%, closer to the initial plan (p = 0.05). Mean rectal V75 was also improved with a value of 0.59 cm(3). There was no significant change in bladder and urethra dose on day 2. Conclusions: A mean interfraction catheter displacement of 5.1 mm results in a significant decrease in prostate V100 And an increase in rectum dose. A reoptimization before the second treatment improves dose distribution. (C) 2011 Elsevier Inc.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [21] High dose-rate brachytherapy in the treatment of prostate cancer
    Mendez, Lucas C.
    Morton, Gerard C.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 357 - 370
  • [22] Role of high dose rate brachytherapy in the treatment of prostate cancer
    Ghilezan, M.
    CANCER RADIOTHERAPIE, 2012, 16 (5-6): : 418 - 422
  • [23] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [24] Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI
    Buus, Simon
    Lizondo, Maria
    Hokland, Steffen
    Rylander, Susanne
    Pedersen, Erik M.
    Tanderup, Kari
    Bentzen, Lise
    BRACHYTHERAPY, 2018, 17 (01) : 50 - 58
  • [25] Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer
    Aebersold, DM
    Isaak, B
    Thalmann, G
    Behrensmeier, F
    Kolotas, C
    Kranzbühler, H
    Mini, R
    Greiner, RH
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 (06) : 351 - 357
  • [26] Use of cone-beam imaging to correct for catheter displacement in high dose-rate prostate brachytherapy
    Holly, Rick
    Morton, Gerard C.
    Sankreacha, Raxa
    Law, Niki
    Cisecki, Thomas
    Loblaw, D. Andrew
    Chung, Hans T.
    BRACHYTHERAPY, 2011, 10 (04) : 299 - 305
  • [27] On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy
    Peppa, Vasiliki
    Pappas, Eleftherios
    Major, Tibor
    Takacsi-Nagy, Zoltan
    Pantelis, Evaggelos
    Papagiannis, Panagiotis
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (01) : 92 - 97
  • [28] A Brief Review of Low-Dose Rate (LDR) and High-Dose Rate (HDR) Brachytherapy Boost for High-Risk Prostate
    Fischer-Valuck, Benjamin W.
    Gay, Hiram A.
    Patel, Sagar
    Baumann, Brian C.
    Michalski, Jeff M.
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [29] Dosimetric evaluation of Gammamed High Dose Rate intraluminal brachytherapy applicators
    Supe, Sanjay Sudhakar
    Varatharaj, Chandraraj
    Bijina, Themantavida Krishnan
    Bondel, Shwetha
    Sathiyan, Saminathan
    Ganesh, Kadirampatti Mani
    Arunkumar, Thangaraj
    Ravikumar, Manickam
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2007, 12 (06) : 313 - 317
  • [30] Evaluation of the dosimetric impact of loss and displacement of seeds in prostate low-dose-rate brachytherapy
    Wang, Yinkun
    Nasser, Nicola J.
    Borg, Jette
    Saibishkumar, Elantholi P.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (03) : 203 - 210