Survey of radiator temperatures in buildings supplied by district heating

被引:60
作者
Jangsten, M. [1 ]
Kensby, J. [1 ]
Dalenback, J. -O. [1 ]
Truschel, A. [1 ]
机构
[1] Chalmers Univ Technol, Div Bldg Serv Engn, Dept Civil & Environm Engn, SE-41296 Gothenburg, Sweden
关键词
Radiator temperatures; Radiator constant; Low-temperature district heating; 4GDH; SINGLE-FAMILY HOUSES; ENERGY PERFORMANCE; SUBSTATIONS; SYSTEMS;
D O I
10.1016/j.energy.2017.07.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to maintain the competitiveness and improve the environmental performance of district heating in the future, it is essential to transition to lower operating temperatures than those of current third generation district heating systems. Heat demands are expected to decrease as buildings become more energy efficient, and new types of heat sources are likely to be integrated. Therefore, future supply and return temperatures of 50-55 degrees C and 20-30 degrees C, have been suggested for the fourth-generation district heating systems. Previous studies on radiator temperatures are limited to the radiator's design conditions for modeling purposes, and there are no published studies that have established what the actual supply and return temperatures in radiator systems are. The purpose of this study is therefore to investigate what the temperatures are and to provide statistics on the radiator temperatures on the secondary side of district heating systems. The results, incorporating data from 109 radiator systems located in Gothenburg's district heating system, showed that the average supply and return temperatures for design outdoor temperature -16 degrees C are 64 degrees C and 42 degrees C, respectively. For an outdoor temperature of 5 degrees C or more all radiator systems had supply temperatures of 55 degrees C or less. The results also showed that radiator systems with a large radiator heat transfer area had the largest potential for lower radiator operating temperatures, as indicated by the normalized radiator constant and the specific space heating demand. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:292 / 301
页数:10
相关论文
共 23 条
  • [1] Frederiksen S, 2013, DISTRICT HEATING COO
  • [2] Fault detection in district heating substations
    Gadd, Henrik
    Werner, Sven
    [J]. APPLIED ENERGY, 2015, 157 : 51 - 59
  • [3] Achieving low return temperatures from district heating substations
    Gadd, Henrik
    Werner, Sven
    [J]. APPLIED ENERGY, 2014, 136 : 59 - 67
  • [4] Changes in heat load profile of typical Danish multi-storey buildings when energy-renovated and supplied with low-temperature district heating
    Harrestrup, Maria
    Svendsen, Svend
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2015, 34 (3-4) : 232 - 247
  • [5] A combined low temperature water heating system consisting of radiators and floor heating
    Hasan, Ala
    Kurnitski, Jarek
    Jokiranta, Kai
    [J]. ENERGY AND BUILDINGS, 2009, 41 (05) : 470 - 479
  • [6] Experimental study of energy performance in low-temperature hydronic heating systems
    Hesaraki, Arefeh
    Bourdakis, Eleftherios
    PIoskic, Adnan
    Holmberg, Sture
    [J]. ENERGY AND BUILDINGS, 2015, 109 : 108 - 114
  • [7] Incropera F., 2005, FUNDAMENTALS HEAT MA
  • [8] Jangsten M, 2016, THESIS
  • [9] Johansson P. Q., 2011, THESIS
  • [10] Adaptive control of radiator systems for a lowest possible district heating return temperature
    Lauenburg, P.
    Wollerstrand, J.
    [J]. ENERGY AND BUILDINGS, 2014, 72 : 132 - 140