Case report: Recurrent severe mitral regurgitation due to ruptured artificial chords after transapical Neochord mitral valve repair
被引:0
作者:
Zhou, Mi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Zhou, Mi
[1
]
Un, Ka-chun
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Un, Ka-chun
[1
]
Wong, Chun Ka
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Wong, Chun Ka
[1
]
Wong, On Yat
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Anesthesiol, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Wong, On Yat
[2
]
Siu, David Chung Wah
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Siu, David Chung Wah
[1
]
Yin, Lixue
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Prov Peoples Hosp, Cardiovasc Ultrasound & Noninvas Cardiol Dept, Chengdu, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Yin, Lixue
[3
]
Chan, Daniel Tai-leung
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Cardiothorac Surg, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Chan, Daniel Tai-leung
[4
]
Lam, Simon Cheung Chi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R ChinaUniv Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
Lam, Simon Cheung Chi
[1
]
机构:
[1] Univ Hong Kong, Queen Mary Hosp, Dept Med, Cardiol Div, Hong Kong, Peoples R China
[2] Univ Hong Kong, Queen Mary Hosp, Dept Anesthesiol, Hong Kong, Peoples R China
[3] Sichuan Prov Peoples Hosp, Cardiovasc Ultrasound & Noninvas Cardiol Dept, Chengdu, Peoples R China
[4] Univ Hong Kong, Queen Mary Hosp, Dept Cardiothorac Surg, Hong Kong, Peoples R China
Transapical Neochord mitral valve repair has been proven to be a technically safe procedure to correct primary mitral regurgitation (MR). Recurrent MR due to ruptured artificial chords is rare. Here, we present 2 cases of recurrent severe MR due to the detached or partially ruptured artificial chords after the Neochord procedure.