Prospective Comparison of Computed Tomography Enterography and Magnetic Resonance Enterography for Assessment of Disease Activity and Complications in Ileocolonic Crohn's Disease

被引:180
作者
Fiorino, G. [1 ]
Bonifacio, C. [2 ]
Peyrin-Biroulet, L. [3 ,4 ]
Minuti, F. [5 ]
Repici, A. [6 ]
Spinelli, A. [7 ]
Fries, W. [8 ]
Balzarini, L. [2 ]
Montorsi, M. [7 ]
Malesci, A. [1 ,9 ]
Danese, S. [1 ]
机构
[1] Ist Clin Humanitas, IBD Unit, Div Gastroenterol, I-20089 Milan, Italy
[2] Ist Clin Humanitas, Radiol Unit, I-20089 Milan, Italy
[3] Univ Hosp Nancy, Dept Hepatogastroenterol, Vandoeuvre Les Nancy, France
[4] Univ Hosp Nancy, INSERM, U954, Vandoeuvre Les Nancy, France
[5] Ist Clin Humanitas, Clin Trial Off, I-20089 Milan, Italy
[6] Ist Clin Humanitas, Digest Endoscopy Unit, I-20089 Milan, Italy
[7] Ist Clin Humanitas, Surg Unit, I-20089 Milan, Italy
[8] Univ Messina, Messina, Italy
[9] Univ Milan, Dept Translat Med, Milan, Italy
关键词
computed tomography; magnetic resonance enterography; Crohn's disease; BOWEL FOLLOW-THROUGH; CT ENTEROGRAPHY; MR ENTEROCLYSIS; CONVENTIONAL ENTEROCLYSIS; RADIATION-EXPOSURE; MURAL ATTENUATION; SPIRAL-CT; METAANALYSIS; ENDOSCOPY; THICKNESS;
D O I
10.1002/ibd.21533
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Studies comparing magnetic resonance enterography (MRE) and computerized tomography enterography (CTE) for Crohn's disease (CD) are scarce. Methods: The aim of this study was to prospectively compare the sensitivity, specificity, and accuracy of abdominal MRE and CTE to assess disease activity and complications (fistulas, strictures) in ileocolonic CD. A total of 44 patients (23 male; 21 female; mean age 44) with ileocolonic CD underwent both MR and CT in a short time interval (mean 5 days). A 16-slice CT with intravenous contrast and an MRI with oral and paramagnetic intravenous contrast were performed. Ileocolonoscopy was used as the reference standard. Sensitivity values of CT and MR for detection of extraenteric signs of disease were compared with the McNemar test, with results of imaging studies, surgery, and physical examination as reference standards. Results: No significant differences in sensitivity, specificity, and accuracy were observed between MRE and CTE regarding the following parameters at the patient level: localization of CD (P = 1.0), bowel wall thickening (P = 1.0), bowel wall enhancement (P = 1.0), enteroenteric fistulas (P = 0.08), detection of abdominal nodes (P = 1.0), and perivisceral fat enhancement (P = 0.31). MR was significantly superior compared to CT in detecting strictures (P = 0.04). Per segment analysis showed that MRE was significantly superior to CTE in detecting ileal wall enhancement (P = 0.02). Conclusions: MR and CT are equally accurate to assess disease activity and bowel damage in CD. MR may be superior to CT in detecting intestinal strictures and ileal wall enhancement. MR may represent an alternative technique to CT in assessing ileocolonic CD. (Inflamm Bowel Dis 2011;17:1073-1080)
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 37 条
[1]   Multislice CT compared to small bowel follow-through in the evaluation of patients with Crohn disease [J].
Amitai, Marianne Michal ;
Arazi-Kleinman, Tal ;
Hertz, Marjorie ;
Apter, Sara ;
Portnoy, Orith ;
Guranda, Larissa ;
Chowers, Yehuda ;
Avidan, Benjamin .
CLINICAL IMAGING, 2008, 32 (05) :355-361
[2]   Mural Attenuation in Normal Small Bowel and Active Inflammatory Crohn's Disease on CT Enterography: Location, Absolute Attenuation, Relative Attenuation, and the Effect of Wall Thickness [J].
Baker, Mark E. ;
Walter, James ;
Obuchowski, Nancy A. ;
Achkar, Jean-Paul ;
Einstein, David ;
Veniero, Joseph C. ;
Vogel, Jon ;
Stocchi, Luca .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) :417-423
[3]   A prospective comparison study of MRI versus small bowel follow-through in recurrent Crohn's disease [J].
Bernstein, CN ;
Greenberg, H ;
Boult, I ;
Chubey, S ;
Leblanc, C ;
Ryner, L .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (11) :2493-2502
[4]   Crohn disease: Mural attenuation and thickness at contrast-enhanced CT enterography - Correlation with endoscopic and histologic findings of inflammation [J].
Bodily, KD ;
Fletcher, JG ;
Solem, CA ;
Johnson, CD ;
Fidler, JL ;
Barlow, JM ;
Bruesewitz, MR ;
McCollough, CH ;
Sandborn, WJ ;
Loftus, EV ;
Harmsen, WS ;
Crownhart, BS .
RADIOLOGY, 2006, 238 (02) :505-516
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[7]   Spiral CT: how much does radiation dose matter? [J].
Dixon, AK ;
Dendy, P .
LANCET, 1998, 352 (9134) :1082-1083
[8]   Dynamic contrast-enhanced MRI of the bowel wall for assessment of disease activity in Crohn's disease [J].
Florie, J ;
Wasser, MNJM ;
Arts-Cieslik, K ;
Akkerman, EM ;
Siersema, PD ;
Stoker, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) :1384-1392
[9]   Natural history and clinical behavior of Crohn's disease extending beyond two decades [J].
Freeman, HJ .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 2003, 37 (03) :216-219
[10]   Imaging of small intestinal Crohn's disease: comparison between MR enteroclysis and conventional enteroclysis [J].
Gourtsoyiannis, Nicholas C. ;
Grammatikakis, John ;
Papamastorakis, George ;
Koutroumbakis, John ;
Prassopoulos, Panos ;
Rousomoustakaki, Maria ;
Papanikolaou, Nickolas .
EUROPEAN RADIOLOGY, 2006, 16 (09) :1915-1925