Adverse patient reactions during orthodontic treatment with fixed appliances

被引:13
作者
Kerosuo, Heidi M. [1 ,2 ]
Dahl, Jon E. [2 ]
机构
[1] Univ Turku, Inst Dent, Dept Orthodont, FIN-20520 Turku, Finland
[2] Nord Inst Dent Mat, Haslum, Norway
关键词
D O I
10.1016/j.ajodo.2007.01.022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Our aims in this study were to assess adverse patient reactions during orthodontic treatment with nickel-containing appliances and to investigate the need for and the use of nickel-free devices in orthodontic practices in Finland and Norway. Methods: A questionnaire was mailed to orthodontists and dentists versed in orthodontics in both countries. They were asked to retrospectively assess the number of patients with adverse reactions and to describe the reactions, the appliances used, and any implications on treatment. Previous history of nickel allergy of patients with adverse reactions, and use of and need for nickel-free appliances in clinical practice were also addressed. Results: Forty-six percent of the respondents (n = 298) reported at least 1 adverse patient reaction during the last 5 years. More than half of the reactions had implications for the treatment. Finnish respondents observed significantly more adverse patient reactions than their Norwegian colleagues, and, in Finland, the adverse reactions were most frequently attributed to headgear treatment. Using nickel-containing fixed appliances in nickel-allergic patients was more common in Finland (77% of the respondents) than in Norway (65%). Conclusions: Nearly half of the dentists regularly working with fixed appliances had observed at least 1 adverse patient reaction during treatment. Nickel-containing fixed appliances are generally used in most patients-even those with a suspected nickel allergy.
引用
收藏
页码:789 / 795
页数:7
相关论文
共 26 条
  • [1] BJORKMAN L, 2001, NOR TANNLEGEFOREN TI, V111, P22
  • [2] Brantley W.A., 2001, ORTHODONTIC MAT SCI, P78
  • [3] Nickel allergy associated with a transpalatal arch appliance; [Nickelallergie bei Verwendung eines Transpalatinalbogens]
    Amy L. Counts
    Marlo A. Miller
    Milan L. Khakhria
    Steven Strange
    [J]. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2002, 63 (6): : 509 - 515
  • [4] Eliades T, 2002, ANGLE ORTHOD, V72, P222
  • [5] ALLERGIC CONTACT-DERMATITIS TO NICKEL - BIOAVAILABILITY FROM CONSUMER PRODUCTS AND PROVOCATION THRESHOLD
    EMMETT, EA
    RISBY, TH
    JIANG, L
    SEE, KN
    FEINMAN, S
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1988, 19 (02) : 314 - 322
  • [6] Experimental nickel elicitation thresholds -: a review focusing on occluded nickel exposure
    Fischer, LA
    Menné, T
    Johansen, JD
    [J]. CONTACT DERMATITIS, 2005, 52 (02) : 57 - 64
  • [7] Characterization of nickel-induced allergic contact stomatitis associated with fixed orthodontic appliances
    Genelhu, MCLS
    Marigo, M
    Alves-Oliveira, LF
    Malaquias, LCC
    Gomez, RS
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (03) : 378 - 381
  • [8] COMPOSITION AND INVITRO CORROSION OF ORTHODONTIC APPLIANCES
    GRIMSDOTTIR, MR
    GJERDET, NR
    HENSTENPETTERSEN, A
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1992, 101 (06) : 525 - 532
  • [9] HENSTENPETTERSE.A, 2003, IN VIVO AGING DENTAL
  • [10] Hindsen M, 1999, Am J Contact Dermat, V10, P62, DOI 10.1016/S1046-199X(99)90001-5