Evaluation of Two Methods for Determining Shell Thicknesses of Core-Shell Nanoparticles by X-ray Photoelectron Spectroscopy

被引:16
作者
Powell, C. J. [1 ]
Werner, W. S. M. [2 ]
Shard, A. G. [3 ]
Castner, D. G. [4 ,5 ]
机构
[1] NIST, Mat Measurement Sci Div, Gaithersburg, MD 20899 USA
[2] Vienna Univ Technol, Inst Appl Phys, Wiedner Hauptstr 8-10, A-1040 Vienna, Austria
[3] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
[4] Univ Washington, Natl ESCA & Surface Anal Ctr Biomed Problems, Dept Chem Engn, Seattle, WA 98195 USA
[5] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
EFFECTIVE ATTENUATION LENGTHS; AUGER-ELECTRON-SPECTROSCOPY; XPS; CATALYSTS; INTENSITIES; SIMULATION; SPECTRA; SILICON; TOOL;
D O I
10.1021/acs.jpcc.6b07588
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We evaluated two methods for determining shell thicknesses of core-shell nanoparticles (NPs) by X-ray photoelectron spectroscopy. One of these methods had been developed for determining thicknesses of films on a planar substrate while the other was developed specifically for NPs. Our evaluations were based on simulated Cu 2p(3/2) spectra from Cu-core/Cu-shell NPs with a wide range of core diameters and shell thicknesses. Copper was chosen for our tests because elastic-scattering effects for Cu 2p(3/2) photoelectrons excited by Al K alpha X-rays are known to be strong. Elastic scattering could also be switched off in our simulations so that the two methods could be evaluated in the limit of no elastic scattering. We found that the first method, based on both core and shell photoelectron intensities, was unsatisfactory for all conditions. The second method, based on an empirical equation for NPs developed by Shard, also utilized both core and shell photoelectron intensities and was found to be satisfactory for all conditions. The average deviation between shell thicknesses derived from the Shard equation and the true values was -4.1% when elastic scattering was switched on and -2.2% when elastic scattering was switched off If elastic scattering was switched on, the effective attenuation length for a Cu film on a planar substrate was the appropriate length parameter while the inelastic mean free path was the appropriate parameter when elastic scattering was switched off.
引用
收藏
页码:22730 / 22738
页数:9
相关论文
共 38 条
[21]   Determination of Internal Structures of Heterogeneous Nanocrystals Using Variable-Energy Photoemission Spectroscopy [J].
Mukherjee, Sumanta ;
Hazarika, Abhijit ;
Santra, Pralay K. ;
Abdelhady, Ahmed L. ;
Malik, Mohammad Azad ;
Gorgoi, Mihaela ;
O'Brien, P. ;
Karis, O. ;
Sarma, D. D. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2014, 118 (28) :15534-15540
[22]   Comparison of 20nm silver nanoparticles synthesized with and without a gold core: Structure, dissolution in cell culture media, and biological impact on macrophages [J].
Munusamy, Prabhakaran ;
Wang, Chongmin ;
Engelhard, Mark H. ;
Baer, Donald R. ;
Smith, Jordan N. ;
Liu, Chongxuan ;
Kodali, Vamsi ;
Thrall, Brian D. ;
Chen, Shu ;
Porter, Alexandra E. ;
Ryan, Mary P. .
BIOINTERPHASES, 2015, 10 (03) :1-16
[23]   Effective attenuation lengths for photoelectrons in thin films of silicon oxynitride and hafnium oxynitride on silicon [J].
Powell, C. J. ;
Werner, W. S. M. ;
Smekal, W. ;
Tasneem, G. .
SURFACE AND INTERFACE ANALYSIS, 2013, 45 (02) :628-638
[24]   Progress in quantitative surface analysis by X-ray photoelectron spectroscopy: Current status and perspectives [J].
Powell, C. J. ;
Jablonski, A. .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2010, 178 :331-346
[25]   Refined calculations of effective attenuation lengths for SiO2 film thicknesses by x-ray photoelectron spectroscopy [J].
Powell, C. J. ;
Werner, W. S. M. ;
Smekal, W. .
APPLIED PHYSICS LETTERS, 2006, 89 (25)
[26]   Surface sensitivity of X-ray photoelectron spectroscopy [J].
Powell, C. J. ;
Jablonski, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 601 (1-2) :54-65
[27]  
Powell C.J., 2011, NIST Electron Effective-Attenuation-Length Database-Version 1.3
[28]   Sample-morphology effects on x-ray photoelectron peak intensities [J].
Powell, Cedric J. ;
Tougaard, Sven ;
Werner, Wolfgang S. M. ;
Smekal, Werner .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2013, 31 (02)
[29]   Electron effective attenuation lengths for applications in Auger-electron spectroscopy and x-ray photoelectron spectroscopy [J].
Powell, CJ ;
Jablonski, A .
SURFACE AND INTERFACE ANALYSIS, 2002, 33 (03) :211-229
[30]   The PENELOPE code system. Specific features and recent improvements [J].
Salvat, Francesc .
ANNALS OF NUCLEAR ENERGY, 2015, 82 :98-109