Comparison of corneal thickness measurements by ultrasound and scheimpflug photography in eyes that have undergone laser in situ keratomileusis

被引:63
作者
Ciolino, Joseph B. [1 ]
Khachikian, Steven S. [1 ]
Belin, Michael W. [1 ,2 ]
机构
[1] Albany Med Coll, Dept Ophthalmol, Albany, NY 12208 USA
[2] Cornea Consultants Albany, Slingerlands, NY USA
关键词
D O I
10.1016/j.ajo.2007.08.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare two methods of measuring central cornea thickness (CCT) in eyes that have under, gone laser in situ keratomileusis (LASIK). DESIGN: Prospective clinical trial. METHODS: The corneal thickness from 104 eyes of 53 consecutive patients undergoing the one-year follow,up after LASIK was measured with both the Pentacam (Oculus, Inc, Wetzlar, Germany) and ultrasonic pachymetry. All patients were examined at one clinical setting, where first Pentacam imaging was performed by one technician and then ultrasound pachymetry was performed by a masked second technician. The results were compared. RESULTS: The average age of the patient population was 38 years (range, 22 to 56 years) of those who underwent the one year follow,up examination an aver, age of 406 days (range, 264 to 579 days) after LASIK. The mean CCT measurement was 506 +/- 29.5 mu m (range, 454 to 574 mu m) with the Pentacam topographer and 505 +/- 31.7 mu m (range, 433 to 576 mu m) with ultrasound pachymetry. The average difference (Pentacam minus ultrasound) was 1.4 +/- 10.4 mu m (range, -21.8 to 23.4 mu m). CONCLUSIONS: The Pentacam's CCT measurement and that of ultrasound pachymetry show good correlation. Pentacam pachymetry may be substituted for ultrasound in the post-LASIK patient.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 24 条
[1]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[2]   Accuracy of Orbscan optical pachymetry in corneas with haze [J].
Boscia, F ;
La Tegola, MG ;
Alessio, G ;
Sborgia, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :253-258
[3]   Comparison of three methods of measuring corneal thickness and anterior chamber depth [J].
Buehl, W ;
Stojanac, D ;
Sacu, S ;
Drexler, W ;
Findl, O .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) :7-12
[4]   Orbscan computerized topography: Attributes, applications, and limitations [J].
Cairns, G ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :205-220
[5]   Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes [J].
Chakrabarti, HS ;
Craig, JP ;
Brahma, A ;
Malik, TY ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1823-1828
[6]   Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye [J].
Chen, Davie ;
Lam, Andrew K. C. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :448-454
[7]   Residual bed thickness and corneal forward shift after laser in situ keratomileusis [J].
Cheng, ACK ;
Tang, E ;
Lam, DSC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11) :2251-2251
[8]  
DREWS C, 1964, OPHTHALMOLOGICA, V148, P143
[9]   Comparison of corneal pachymetry using ultrasound and Orbscan II [J].
Fakhry, MA ;
Artola, A ;
Belda, JL ;
Ayala, MJ ;
Alió, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :248-252
[10]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714