The Effect of Different Condition of Pulpal Pressure on Microtensile Bond Strength of Several Dentin Bonding Agents on Deep and Superficial Dentin

被引:2
作者
Montanari, Marco [1 ]
Fiorillo, Luca [2 ,3 ,4 ]
Cervino, Gabriele [2 ]
Sambataro, Sergio [2 ]
Herford, Alan Scott [5 ]
Cicciu, Marco [2 ]
机构
[1] Univ Ferrara, Dept Prosthodont, Via Luigi Borsari 46, I-44121 Ferrara, Italy
[2] Univ Messina, Dept Biomed & Dent Sci, Morphol & Funct Images, Policlin G Martino, Via Consolare Valeria, I-98100 Messina, Italy
[3] Univ Naples 2, Multidisciplinary Dept Med Surg & Dent Specialtie, I-80100 Naples, Italy
[4] Univ Aldent, Dept Dent, Tirana 1000, Albania
[5] Loma Linda Univ, Dept Maxillofacial Surg, Loma Linda, CA 92354 USA
关键词
pulpal pressure; microtensile bond strength; permeability; hydrophilic monomers; hybrid layer; dentin bonding systems; SEM; SELF-ETCH; IN-VITRO; INTRAPULPAL PRESSURE; FLUID MOVEMENT; WATER SORPTION; HYBRID LAYER; PERMEABILITY; ADHESIVES; STEP; OCCLUSION;
D O I
10.3390/ma14206200
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The objective of this study was to examine the effect of different conditions of simulated hydrostatic pulpal pressure on the mu TBS of HEMA-based and HEMA-free dentin bonding agents (DBAs). The influence of dentin location (deep and superficial) on mu TBS was also evaluated. Flat coronal dentin surfaces of extracted human molars were prepared. Three groups of resin-bonded specimens were exposed to different pulpal pressures. Pulpal pressure was maintained for 20 min for each group. A flowable resin composite was used for coronal build-up. The bonded teeth were sectioned and, after 24 h of water storage, stressed to failure using the microtensile tester (mu TBS). Failed samples were analyzed by SEM inspection. HEMA-based DBAs were much more sensitive to pulpal pressure conditions than non-HEMA-containing DBAs. Pulpal pressure had a greater influence in deep dentin. The HEMA-free DBA was insensitive to the presence or absence of pulpal pressure condition. SEM inspection confirmed a relationship between the presence of voids inside the HEMA-based DBAs layer and the lower mu TBS results. HEMA-based DBAs are more sensitive to pulpal pressure conditions than HEMA-free DBAs. Interestingly, HEMA-free DBA showed a greater number of water droplets at resin-dentin interface in all tested conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] The effect of dentin surface pretreatment using dimethyl sulfoxide on the bond strength of a universal bonding agent to dentin
    Mirzaei, Kianoosh
    Ahmadi, Elham
    Rafeie, Niyousha
    Abbasi, Mahdi
    [J]. BMC ORAL HEALTH, 2023, 23 (01)
  • [22] Effect of Galardin and its Solvents on the Microtensile Bond Strength of Different Adhesive Systems to Dentin
    Chaharom, Mohammad Esmaeel Ebrahimi
    Bahari, Mahmoud
    Rahbar, Mahdi
    Golbaz, Sepideh
    [J]. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2019, 19 (01):
  • [23] Effect of Immediate Dentin Sealing and Surface Conditioning on the Microtensile Bond Strength of Resin-based Composite to Dentin
    van den Breemer, C. R. G.
    Ozcan, M.
    Cune, M. S.
    Ayres, A. P. Almeida
    Van Meerbeek, B.
    Gresnigt, M. M. M.
    [J]. OPERATIVE DENTISTRY, 2019, 44 (06) : E289 - E298
  • [24] Bonding performance of different adhesive systems to deproteinized dentin: Microtensile bond strength and scanning electron microscopy
    de Souza, FB
    Silva, CHV
    Dibb, RGP
    Delfino, CS
    Beatrice, LCD
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (01) : 158 - 167
  • [25] Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure
    Silva, T. M.
    Goncalves, L. L.
    Fonseca, B. M.
    Esteves, S. R. M. S.
    Barcellos, D. C.
    Damiao, A. J.
    Goncalves, S. E. P.
    [J]. LASERS IN MEDICAL SCIENCE, 2016, 31 (01) : 49 - 56
  • [26] Effect of application time of colloidal platinum nanoparticles on the microtensile bond strength to dentin
    Hoshika, Shuhei
    Nagano, Futami
    Tanaka, Toru
    Ikeda, Takatsumi
    Wada, Takahiro
    Asakura, Kiyotaka
    Koshiro, Kenichi
    Selimovic, Denis
    Miyamoto, Yusei
    Sidhu, Sk
    Sano, Hidehiko
    [J]. DENTAL MATERIALS JOURNAL, 2010, 29 (06) : 682 - 689
  • [27] Effect of Different Antioxidants on the Microtensile Bond Strength of an Adhesive System to Sodium Hypochlorite-treated Dentin
    Dikmen, Benin
    Gurbuz, Ozge
    Ozsoy, Alev
    Eren, Meltem Mert
    Cilingir, Aylin
    Yucel, Taner
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2015, 17 (06) : 499 - 504
  • [28] Universal adhesive: the effect of different simulated pulpal pressure fluids and bonding modes to dentin
    Goncalves, Lucelia Lemes
    Da Silva, Tania Mara
    Prakki, Anuradha
    Barcellos, Daphne Camara
    Caneppele, Taciana Marco Ferraz
    De Oliveira, Hueder Paulo Moises
    Goncalves, Sergio Eduardo de Paiva
    [J]. ODONTOLOGY, 2022, 110 (01) : 62 - 69
  • [29] Effect of preheating of low shrinking resin composite on intrapulpal temperature and microtensile bond strength to dentin
    El-Deeb, Heba A.
    El-Aziz, Sara Abd
    Mobarak, Enas H.
    [J]. JOURNAL OF ADVANCED RESEARCH, 2015, 6 (03) : 471 - 478
  • [30] Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength
    Cho, BH
    Dickens, SH
    [J]. DENTAL MATERIALS, 2004, 20 (02) : 107 - 115