Sensitive Determination of 4-n-Nonylphenol in Domestic Wastewater and Liquid Detergent by Binary Solvent Microextraction (BSME) and Gas Chromatography-Mass Spectrometry (GC-MS) with Matrix Matching Calibration
被引:1
|
作者:
Erarpat, Sezin
论文数: 0引用数: 0
h-index: 0
机构:
Yildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, TurkeyYildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
Erarpat, Sezin
[1
]
Bodur, Suleyman
论文数: 0引用数: 0
h-index: 0
机构:
Yildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, TurkeyYildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
Bodur, Suleyman
[1
]
Chormey, Dotse Selali
论文数: 0引用数: 0
h-index: 0
机构:
Yildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, TurkeyYildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
Chormey, Dotse Selali
[1
]
oz, Ersoy
论文数: 0引用数: 0
h-index: 0
机构:
Yildiz Tech Univ, Fac Art & Sci, Dept Stat, Istanbul, TurkeyYildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
oz, Ersoy
[2
]
Bakirdere, Sezgin
论文数: 0引用数: 0
h-index: 0
机构:
Yildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
Turkish Acad Sci TUBA, Ankara, TurkeyYildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
Bakirdere, Sezgin
[1
,3
]
机构:
[1] Yildiz Tech Univ, Fac Art & Sci, Dept Chem, Istanbul, Turkey
[2] Yildiz Tech Univ, Fac Art & Sci, Dept Stat, Istanbul, Turkey
Binary solvent microextraction (BSME) coupled to gas chromatography-mass spectrometry (GC-MS) was employed to determine 4-n-nonylphenol in domestic wastewater and detergent. The developed BSME method was applied to obtain lower detection limits by preconcentrating the analyte before determination by GC-MS. Relevant parameters of the extraction method, including the binary solvent volume, dispersive solvent volume, and vortex period, were optimized using Box-Behnken Design. Under the optimum conditions, the limit of detection (LOD), limit of quantitation, and linear dynamic range were 0.6, 2.0, and 2.0 to 100 ng g(-1), respectively. The extraction procedure provided an approximate 470-fold enhancement in the detection power. Recovery experiments were performed for spiked wastewater and detergent by performing matrix matching calibration. The recoveries obtained by BSME-GC-MS for wastewater and detergent were between 94 and 103% and 91 and 109%, respectively.
机构:
Univ Djilali Bounaama Khemis Miliana, Theniet El Had 44225, Ain Defla, Algeria
Univ Badji Mokhtar, Biosurveillance Environm, BP 12, Annaba 23000, AlgeriaUniv Djilali Bounaama Khemis Miliana, Theniet El Had 44225, Ain Defla, Algeria