Mechatronic Design and Active Disturbance Rejection Control of a Bag Valve-Based Mechanical Ventilator

被引:4
作者
Arcos-Legarda, Jaime [1 ]
Tovar, Andres [2 ]
机构
[1] Univ San Buenaventura, Dept Mechatron Engn, Cr 8h 172-20, Bogota 111156, Colombia
[2] Indiana Univ Purdue Univ, Dept Mech & Energy Engn, 723 West Michigan St,SL 260N, Indianapolis, IN 46202 USA
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2021年 / 15卷 / 03期
关键词
Design; Pressure; Valves; Ventilation; Lung; Engineering prototypes; Actuators; Compression; Hardware;
D O I
10.1115/1.4051064
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the mechatronic (mechanical and control system) design of a functional prototype of a portable mechanical ventilator to treat patients with a compromised respiratory function. The portable ventilator ensures adequate oxygenation and carbon dioxide clearance while avoiding ventilator-induced lung injury (VILI). Oxygen is delivered through the compression of a bag valve (Ambu bag) using a moving strap. Carbon dioxide is cleared through the control of a pinch valve actuated by a low-torque servomotor. The positive end-expiratory pressure (PEEP) is controlled by an adjustable mechanical valve of the system. An Arduino Mega microcontroller board is used in this prototype to control the respiratory variables. All mechanical components as well as sensors, actuators, and control hardware are of common use in robotics and are very inexpensive. The total cost of the prototype built in this work is about $425 U.S. dollars. The design is meant to be replicated and utilized in emergency conditions that involve an overwhelming number of cases, such as COVID-19 treatment, in places with no access to commercial mechanical ventilation (MV) technologies. In order to account for variations in the prototype as built, the software developed for this portable MV applies an active disturbance rejection control (ADRC) strategy. This control strategy is presented as a universal control structure for any mechanical ventilator able to supply air flow with controlled pressure and volume.
引用
收藏
页数:8
相关论文
共 41 条
  • [1] Low-Cost, Open-Source Mechanical Ventilator with Pulmonary Monitoring for COVID-19 Patients
    Acho, Leonardo
    Vargas, Alessandro N.
    Pujol-Vazquez, Gisela
    [J]. ACTUATORS, 2020, 9 (03)
  • [2] Al Husseini Abdul Mohsen, 2010, J Med Device, V4, P027514, DOI 10.1115/1.3442790
  • [3] Amitai A., 2020, MEDSCAPE
  • [4] Hybrid disturbance rejection control of dynamic bipedal robots
    Arcos-Legarda, Jaime
    Cortes-Romero, John
    Beltran-Pulido, Andres
    Tovar, Andres
    [J]. MULTIBODY SYSTEM DYNAMICS, 2019, 46 (03) : 281 - 306
  • [5] Arcos-Legarda J, 2016, P AMER CONTR CONF, P3928, DOI 10.1109/ACC.2016.7525526
  • [6] A dynamic morphometric model of the normal lung for studying expiratory flow limitation in mechanical ventilation
    Barbini, P
    Brighenti, C
    Cevenini, G
    Gnudi, G
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (04) : 518 - 530
  • [7] Bates Jason H T, 2020, Crit Care Explor, V2, pe0299, DOI 10.1097/CCE.0000000000000299
  • [8] Ventilator-induced lung injury and lung mechanics
    Bates, Jason H. T.
    Smith, Bradford J.
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (19)
  • [9] Monitoring and Control System Used in Microalgae Crop
    Beltran, L.
    Castro, C. L. G.
    Garces, F.
    Moreno, M.
    [J]. IEEE LATIN AMERICA TRANSACTIONS, 2012, 10 (04) : 1993 - 1998
  • [10] Bertotti M. L., 2020, arXiv